53500018 | Article: 53500018 Heating sleeve 250W, 180°C, 230 V AC 50 Hz (incl. PT 100, controller required) | AGT-PSG |
80060593 | Article: 80060593 Insulating pad Plus for heating sleeve | AGT-PSG |
53500041 | Article: 53500041 Thermostat control for max. 200°C for heating sleeve | AGT-PSG |
80060528 | Article: 80060528 Filter unit PSG Plus with ceramic filter 0,3µm | AGT-PSG |
53500031 | Article: 53500031 Protective case PSG Plus incl. junction box and mounting set for heated sample line, insulated (for heating with thermostat control) | AGT-PSG |
53500018 | Article: 53500018 Heating sleeve 250W, 180°C, 230 V AC 50 Hz (incl. PT 100, controller required) | AGT-PSG |
80060593 | Article: 80060593 Insulating pad Plus for heating sleeve | AGT-PSG |
53500062 | Article: 53500062 Tubing test gas connection | AGT-PSG |
53500044 | Article: 53500044 Tubing back purging 2-stage (double) | AGT-PSG |
53500041 | Article: 53500041 Thermostat control for max. 200°C for heating sleeve | AGT-PSG |
53402004 | Article: 53402004 PSG Plus DSBP, 230V 50/60Hz, with PID-controller ST49 and solid state relais for DIN-rail mounting | AGT-PSG |
53402011 | Article: 53402011 PSG Plus DSBP, 115V 50/60Hz, with PID-controller ST49 and solid state relais for DIN-rail mounting | AGT-PSG |
53402006 | Article: 53402006 PSG Plus DSBP, 230V 50/60Hz, with thermostat controller in connection box | AGT-PSG |
53402012 | Article: 53402012 PSG Plus DSBP, 115V 50/60Hz, with thermostat controller in connection box | AGT-PSG |
53500055 | Article: 53500055 Extra charge for 1 Coax solenoid valve mounted at the probe and wired to connection box, voltage 230VAC | AGT-PSG |
53500056 | Article: 53500056 Extra charge for 1 Coax solenoid valve mounted at the probe and wired to connection box, voltage 24VDC | AGT-PSG |
53500045 | Article: 53500045 Extra charge for 2 Coax solenoid valves mounted at the probe and wired to connection box, voltage 230VAC | AGT-PSG |
53500057 | Article: 53500057 Extra charge for 2 Coax solenoid valves mounted at the probe and wired to connection box, voltage 24VDC | AGT-PSG |
80060638 | Article: 80060638 FFKM instead of FPM sealings for heating to 315°C or corrosion resistant version (with back purging) | AGT-PSG |
80060195 | Article: 80060195 Pressure reduction valve PSG PR, SS316Ti, ?“ RT m – 6mm tube | AGT-PSG |
80060675 | Article: 80060675 Pressure reduction valve PSG PR, SS316Ti, ?“ RT m – 8mm tube | AGT-PSG |
53001192 | Article: 53001192 Pressure accumulator 2L, material stainless steel, mounted at probe connected with 12mm tube at Coax valves, max. operating pressure 7bar, pressure air connection 12mm tube | AGT-PSG |
53500038 | Article: 53500038 Extra charge for additional insulation of protective housing for ambient temperatures -30°C | AGT-PSG |
53500069 | Article: 53500069 Corrosion resistant coating of internal probe surface | AGT-PSG |
80060022 | Article: 80060022 Probe tube SS316Ti, max. 550°C, length = 1000 mm, ?27mm o, R3/4”m | AGT-PSG |
80060645 | Article: 80060645 Additional 100mm probe and extension tube SS316Ti | AGT-PSG |
8060438 | Article: 8060438 Probe tube C4, max. 900°C, length = 1000 mm, ?25mm o, R3/4“m | AGT-PSG |
80060646 | Article: 80060646 Additional 100mm probe and extension tube Hastelloy C4 | AGT-PSG |
80060388 | Article: 80060388 Probe tube 253 MA, max. 900°C, length = 1000 mm, ? 27mm a, R3/4“m | AGT-PSG |
80060647 | Article: 80060647 Additional 100mm probe tube 253 MA | AGT-PSG |
80060650 | Article: 80060650 Probe tube Inconel 601, max. 1200°C, length = 1000 mm, ? 27mm a, R3/4“a | AGT-PSG |
80060651 | Article: 80060651 Additional 100mm probe tube Inconel 601 | AGT-PSG |
80060652 | Article: 80060652 Probe tube Alloy HR160, max. 1200°C, length = 1000 mm, ? 27mm a, R3/4“a | AGT-PSG |
80060653 | Article: 80060653 Additional 100mm probe tube Alloy HR160 | AGT-PSG |
80060660 | Article: 80060660 Probe tube Kanthal APM, max. 1300°C, length = 1000 mm, ? 27mm a, R3/4“a | AGT-PSG |
80060661 | Article: 80060661 Additional 100mm probe tube Kanthal APM | AGT-PSG |
80060492 | Article: 80060492 Sinter metal pre-filter 2µm, stainless steel, max. 550°C, length = 220 mm, G3/4“i | AGT-PSG |
80060572 | Article: 80060572 Sinter metal pre-filter 2µm, stainless steel, max. 550°C, length = 520 mm, G3/4“i | AGT-PSG |
80060526 | Article: 80060526 Extension tube SS316Ti, max. 550°C, length = 1000 mm, ? 26mm a, R3/4“a – G3/4“i | AGT-PSG |
80060645 | Article: 80060645 Additional 100mm probe and extension tube SS316Ti | AGT-PSG |
80060493 | Article: 80060493 Deflector 1.4571, max. 550°C, length = 220 mm | AGT-PSG |
80060632 | Article: 80060632 Deflector 1.4571, max. 550°C, length = 520 mm | AGT-PSG |
80060670 | Article: 80060670 Heated gas sampling tube 1.4571, HT: 180°C, PT100, temp. resistant to 250°C, length = 500 mm | AGT-PSG |
80060671 | Article: 80060671 Heated gas sampling tube 1.4571, HT: 180°C, PT100, temp. resistant to 250°C, length = 1000 mm | AGT-PSG |
80060672 | Article: 80060672 Heated gas sampling tube 1.4571, HT: 180°C, PT100, temp. resistant to 250°C, length = 1500 mm | AGT-PSG |
80060673 | Article: 80060673 Heated gas sampling tube 1.4571, HT: 180°C, PT100, temp. resistant to 250°C, length = 2000 mm | AGT-PSG |
80060730 | Article: 80060730 Heated gas sampling tube 1.4571, HT: 180°C, PT100, temp. resistant to 450°C, length = 500 mm | AGT-PSG |
80060731 | Article: 80060731 Heated gas sampling tube 1.4571, HT: 180°C, PT100, temp. resistant to 450°C, length = 1000 mm | AGT-PSG |
80060732 | Article: 80060732 Heated gas sampling tube 1.4571, HT: 180°C, PT100, temp. resistant to 450°C, length = 1500 mm | AGT-PSG |
80060733 | Article: 80060733 Heated gas sampling tube 1.4571, HT: 180°C, PT100, temp. resistant to 450°C, length = 2000 mm | AGT-PSG |