General Information | |
Global Commercial Alias: | PSTX570-600-70 |
Extended Product Type: | PSTX570-600-70 |
Product ID: | 1SFA898117R7000 |
ABB Type Designation: | PSTX570-600-70 |
EAN: | 7320500508992 |
Catalog Description: | PSTX570-600-70 Softstarter |
Long Description: | Softstarter PSTX570-600-70 for max 600V main voltage and 100 - 250V 50/60Hz control supply voltage. |
Interactive Guides | |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85044090 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SFC132012C0201 |
Instructions and Manuals: | 1SFC132081M0201 |
| |
Product Net Width: | 361 mm |
Product Net Height: | 493 mm |
Product Net Depth / Length: | 282 mm |
Product Net Weight: | 27 kg |
| |
Rated Operational Voltage: | 208 ... 600 V AC |
Rated Control Supply Voltage (Us): | 100 ... 250 V AC |
Rated Control Circuit Voltage (Uc): | DC Operation 24 V |
Rated Frequency (f): | 50/60 Hz |
Main Circuit 50 / 60 Hz | |
Rated Operational Power - In-Line Connection (Pe): | (230 V) 160 kW |
(400 V) 315 kW | |
(500 V) 400 kW | |
Rated Operational Current - In-Line Connection (Ie): | 570 A |
Rated Operational Power - Inside Delta Connection: | at 230 V 295 kW |
at 400 V 540 kW | |
at 500 V 700 kW | |
Rated Operational Current - Inside Delta Connection: | 987 A |
Service Factor Percentage: | 100 % |
Overload Protection: | Built-in electronic overload protection |
Integrated Electronic Overload: | Yes |
Adjustable Rated Motor Current Ie: | 30 ... 100 % |
Starting Capacity at Maximum Rated Current Ie: | 4xIe for 10s |
Ramp Time: | 1 ... 120 second [unit of time] |
Initial Voltage During Start: | 10 ... 99 % |
Step Down Voltage Special Ramp: | 100 ... 10 % |
Switch for Inside Delta Connection: | Yes |
Run Signal Relay: | Yes |
By-pass Signal Relay: | Yes |
Fault Signal Relay: | Yes |
Overload Signal Relay: | Yes |
Signal indication ready to start/standby ON (LED): | Green |
Signal indication running R (LED): | Green |
Signal indication protection (LED): | Yellow |
Signal indication fault (LED): | Red |
Communication: | Built in Modbus interface, Anybus, FieldBusPlug (with adapter). |
Degree of Protection: | IP00 |
Terminal Type: | Main Circuit: Bars |
Connecting Capacity Control Circuit: | Rigid 1 x 2.5 mm² |
Connecting Capacity Supply Circuit: | Rigid 1 x 2.5 mm² |
Tightening Torque: | Main Circuit 35 N·m |
Product Main Type: | PSTX570 |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V |
Ampere Rating UL/CSA: | 590 A |
Tightening Torque UL/CSA: | Main Circuit 309.8 in·lb |
| |
Ambient Air Temperature: | Operation -25 ... +60 °C |
Storage -40 ... +70 °C | |
RoHS Status: | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| |
CQC Certificate: | CN: CQC2015010304806588 / SE: CQC2015010304797766 |
Declaration of Conformity - CCC: | CN: 2020980304001094 / SE: 2020980304001859 |
Declaration of Conformity - CE: | 2CMT005209 |
Environmental Information: | 2CMT005232 |
Instructions and Manuals: | 1SFC132081M0201 |
RoHS Information: | 2CMT005210 |
| |
Package Level 1 Width: | 470 mm |
Package Level 1 Depth / Length: | 381 mm |
Package Level 1 Height: | 650 mm |
Package Level 1 Gross Weight: | 31 kg |
Package Level 1 EAN: | 7320500508992 |
Package Level 1 Units: | box 1 piece |
| |
Object Classification Code: | Q |
ETIM 6: | EC002572 - Motor management device |
UNSPSC: | 39121521 |