Article: A12-30-10 105V 50Hz / 110-127V 60Hz

Article: A12-30-10 105V 50Hz / 110-127V 60Hz
A12-30-10 105V 50Hz / 110-127V 60Hz Contactor
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
| Extended Product Type: | A12-30-10 105V 50Hz / 110-127V 60Hz |
| Product ID: | 1SBL161001R2610 |
| EAN: | 3471522042262 |
| Catalog Description: | A12-30-10 105V 50Hz / 110-127V 60Hz Contactor |
| Long Description: | A12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available. |
| |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information: | 1SBC100122C0202_Ch02 |
| Instructions and Manuals: | FPTC407721P0001 |
| |
| Product Net Width: | 44 mm |
| Product Net Depth / Length: | 74 mm |
| Product Net Height: | 74 mm |
| Product Net Weight: | 0.34 kg |
| |
| Number of Main Contacts NO: | 3 |
| Number of Main Contacts NC: | 0 |
| Number of Auxiliary Contacts NO: | 1 |
| Number of Auxiliary Contacts NC: | 0 |
| Standards: | Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1 |
| Rated Operational Voltage: | Main Circuit 690 V |
| Rated Frequency (f): | Supply Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 28 A |
| acc. to IEC 60947-5-1, q = 40 °C 16 A | |
| Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 27 |
| (690 V) 55 °C 25 | |
| (690 V) 70 °C 20 | |
| Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 12 A |
| (440 V) 55 °C 12 A | |
| (500 V) 55 °C 12 A | |
| (690 V) 55 °C 9 A | |
| (380 / 400 V) 55 °C 12 A | |
| (220 / 230 / 240 V) 55 °C 12 | |
| Rated Operational Power AC-3 (Pe): | (415 V) 5.5 kW |
| (440 V) 5.5 kW | |
| (500 V) 7.5 kW | |
| (690 V) 7.5 kW | |
| (380 / 400 V) 5.5 kW | |
| (220 / 230 / 240 V) 3 kW | |
| Rated Operational Power AC-6b (Pe): | (230 / 240 V) 40 °C, 50 / 60 Hz 7 kvar |
| (230 / 240 V) 55 °C, 50 / 60 Hz 7 kvar | |
| (230 / 240 V) 70 °C, 50 / 60 Hz 6 kvar | |
| (400 / 415 V) 40 °C, 50 / 60 Hz 11 kvar | |
| (400 / 415 V) 70 °C, 50 / 60 Hz 9.5 kvar | |
| (400 / 415 V) 55 °C, 50 / 60 Hz 11 kvar | |
| (440 V) 40 °C, 50 / 60 Hz 12 kvar | |
| (440 V) 55 °C, 50 / 60 Hz 12 kvar | |
| (440 V) 70 °C, 50 / 60 Hz 10.5 kvar | |
| (500 / 550 V), 40 °C, 50 / 60 Hz 14 kvar | |
| (500 / 550 V) 55 °C, 50 / 60 Hz 14 kvar | |
| (500 / 550 V) 70 °C, 50 / 60 Hz 12 kvar | |
| (690 V) 40 °C, 50 / 60 Hz 19 kvar | |
| (690 V) 55 °C, 50 / 60 Hz 19 kvar | |
| (690 V) 70 °C, 50 / 60 Hz 16.5 kvar | |
| Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
| Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
| (690 V) 2 A | |
| (24 / 127 V) 6 A | |
| (220 / 240 V) 4 A | |
| (380 / 400 V) 3 A | |
| Short-Circuit Protective Devices: | Auxiliary Circuit - gG Type Fuses 10 A |
| gG Type Fuses 32 A | |
| Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A | |
| Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
| (AC-2 / AC-4) 300 cycles per hour | |
| (AC-3) 1200 cycles per hour | |
| Rated Operational Current DC-13 (Ie): | (24 V) 6 / 144 A |
| (48 V) 2.8 / 134 A | |
| (72 V) 2 / 144 A | |
| (125 V) 1.1 / 138 A | |
| (250 V) 0.55 / 138 A | |
| Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc): | 50 Hz 105 V |
| 60 Hz 110 ... 127 V | |
| Coil Consumption: | Average Holding Value 50 Hz 8 V·A |
| Average Holding Value 60 Hz 8 V·A | |
| Average Pull-in Value 50 Hz 70 V·A | |
| Average Pull-in Value 60 Hz 80 V·A | |
| Operate Time: | Between Coil De-energization and NO Contact Opening 4 ... 11 ms |
| Between Coil Energization and NO Contact Closing 10 ... 26 ms | |
| Connecting Capacity Main Circuit: | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Connecting Capacity Auxiliary Circuit: | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Connecting Terminals (delivered in open position) Main Poles: | M 3.5 (+,-) pozidriv 2 screws with cable clamp |
| Terminal Type: | Screw Terminals |
| |
| Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C | |
| Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Climatic Withstand: | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
| Maximum Operating Altitude Permissible: | 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: B1 10 K40 |
| Open, Shock Direction: B1 5 K40 | |
| Shock Direction: A 20 K40 | |
| Shock Direction: B2 15 K40 | |
| Shock Direction: C1 20 K40 | |
| Shock Direction: C2 20 K40 | |
| RoHS Status: | Following EU Directive 2011/65/EU |
| |
| BV Certificate: | BV_2634H07559E0 |
| CB Certificate: | CB_CN44759 |
| CCC Certificate: | CCC_2018010304059156 |
| CQC Certificate: | CQC2013010304615753 |
| CQC2018010304059156 | |
| CQC2004010309130463 | |
| CSA Certificate: | CSA_1041746 |
| Declaration of Conformity - CCC: | 2020980304001607 |
| 2020980304001616 | |
| 2020980304001229 | |
| Declaration of Conformity - CE: | 1SBD250801U1000 |
| DNV Certificate: | DNV-GL_TAE00000TX |
| DNV GL Certificate: | DNV-GL_TAE00000TX |
| EAC Certificate: | EAC_RU C-FR ME77 B03599 |
| Environmental Information: | 1SBD250002E1004 |
| Instructions and Manuals: | FPTC407721P0001 |
| LOVAG Certificate: | LOVAG_FR97038 |
| LR Certificate: | LRS_9830011E4 |
| RINA Certificate: | RINA_ELE172319XG001 |
| RMRS Certificate: | RMRS_0507015250 |
| RoHS Information: | 1SBD250801U1000 |
| UL Certificate: | UL_20160205-E312527-10-2 |
| UL Listing Card: | UL_E312527 |
| |
| Package Level 1 Units: | 1 piece |
| Package Level 1 Width: | 78 mm |
| Package Level 1 Depth / Length: | 76 mm |
| Package Level 1 Height: | 47 mm |
| Package Level 1 Gross Weight: | 0.34 kg |
| Package Level 1 EAN: | 3471522042262 |
| Package Level 2 Units: | box 63 piece |
| Package Level 2 Width: | 300 mm |
| Package Level 2 Depth / Length: | 245 mm |
| Package Level 2 Height: | 308 mm |
| Package Level 2 Gross Weight: | 21.42 kg |
| Package Level 3 Units: | 1220 piece |
| |
| Object Classification Code: | Q |
| ETIM 4: | EC000066 - Magnet contactor, AC-switching |
| ETIM 5: | EC000066 - Magnet contactor, AC-switching |
| ETIM 6: | EC000066 - Power contactor, AC switching |
| ETIM 7: | EC000066 - Power contactor, AC switching |
| eClass: | V11.0 : 27371003 |
| UNSPSC: | 39121529 |