A260-30-22 42V 50Hz / 42V 60Hz Contactor
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
| Extended Product Type: | A260-30-22-82 |
| Product ID: | 1SFL531001R8222 |
| EAN: | 7320500213445 |
| Catalog Description: | A260-30-22 42V 50Hz / 42V 60Hz Contactor |
| Long Description: | A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz |
| |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85364900 |
| Replacement Product ID (NEW): | 1SFL547002R1122 |
| Popular Downloads | |
| Data Sheet, Technical Information: | 1SBC100192C0206 |
| Instructions and Manuals: | 1SFC380003-89 |
| Dimension Diagram: | 53540930-2 |
| |
| Product Net Width: | 140 mm |
| Product Net Depth / Length: | 180.5 mm |
| Product Net Height: | 227 mm |
| Product Net Weight: | 5.4 kg |
| |
| Number of Main Contacts NO: | 3 |
| Number of Main Contacts NC: | 0 |
| Number of Auxiliary Contacts NO: | 2 |
| Number of Auxiliary Contacts NC: | 2 |
| Rated Operational Voltage: | Main Circuit 690 V |
| Rated Frequency (f): | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 400 A |
| Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 400 |
| (690 V) 55 °C 350 | |
| (690 V) 70 °C 290 | |
| Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 260 A |
| (440 V) 55 °C 240 A | |
| (500 V) 55 °C 240 A | |
| (690 V) 55 °C 220 A | |
| (380 / 400 V) 55 °C 260 A | |
| (220 / 230 / 240 V) 55 °C 260 | |
| Rated Operational Power AC-3 (Pe): | (415 V) 140 kW |
| (440 V) 140 kW | |
| (500 V) 180 kW | |
| (690 V) 200 kW | |
| (380 / 400 V) 140 kW | |
| (220 / 230 / 240 V) 80 kW | |
| Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
| Short-Circuit Protective Devices: | gG Type Fuses 500 A |
| Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A | |
| Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2600 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2400 A | |
| Maximum Electrical Switching Frequency: | (AC-1) 300 cycles per hour |
| (AC-2 / AC-4) 150 cycles per hour | |
| (AC-3) 300 cycles per hour | |
| Rated Operational Current DC-1 (Ie): | (110 V) 2 Poles in Series, 40 °C 400 A |
| (220 V) 3 Poles in Series, 40 °C 400 A | |
| Rated Operational Current DC-3 (Ie): | (110 V) 2 Poles in Series, 40 °C 400 A |
| (220 V) 3 Poles in Series, 40 °C 400 A | |
| Rated Operational Current DC-5 (Ie): | (110 V) 2 Poles in Series, 40 °C 400 A |
| (220 V) 3 Poles in Series, 40 °C 400 A | |
| Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp): | Main Circuit 8 kV |
| Mechanical Durability: | 5 million |
| Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
| Coil Operating Limits: | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc): | 50 Hz 42 V |
| 60 Hz 42 V | |
| Coil Consumption: | Holding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A | |
| Operate Time: | Between Coil De-energization and NC Contact Closing 7 ... 13 ms |
| Between Coil De-energization and NO Contact Opening 10 ... 16 ms | |
| Between Coil Energization and NC Contact Opening 12 ... 30 ms | |
| Between Coil Energization and NO Contact Closing 17 ... 35 ms | |
| Connecting Capacity Main Circuit: | Bar 32 mm² |
| Rigid Al-Cable 2 x 95 ... 120 mm² | |
| Rigid Cu-Cable 16 ... 240 mm² | |
| Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 1x0.75 ... 2.5 mm² | |
| Solid 2 x 1 ... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
| Connecting Terminals (delivered in open position) Main Poles: | Flat type c/w screws and bolts |
| Terminal Type: | Main Circuit: Bars |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA: | Main Circuit 600 V |
| General Use Rating UL/CSA: | (600 V AC) 350 A |
| Horsepower Rating UL/CSA: | (200 V AC) Three Phase 75 hp |
| (208 V AC) Three Phase 75 hp | |
| (220 ... 240 V AC) Three Phase 100 hp | |
| (440 ... 480 V AC) Three Phase 200 hp | |
| (550 ... 600 V AC) Three Phase 250 hp | |
| |
| Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C | |
| Close to Contactor for Storage -40 ... +70 °C | |
| Maximum Operating Altitude Permissible: | 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27: | Shock Direction: A 5 K40 |
| Shock Direction: B1 5 K40 | |
| Shock Direction: B2 5 K40 | |
| Shock Direction: C1 5 K40 | |
| Shock Direction: C2 5 K40 | |
| RoHS Status: | Following EU Directive 2011/65/EU |
| |
| BV Certificate: | 09826/C0 BV |
| CQC Certificate: | CQC2008010304279325 |
| Declaration of Conformity - CCC: | 2020980304001552 |
| Declaration of Conformity - CE: | 2CMT2015-005436 |
| DNV Certificate: | DNV_E-12191 |
| Environmental Information: | 1SFC101003D0201 |
| GL Certificate: | GL_15529-00HH |
| Instructions and Manuals: | 1SFC380003-89 |
| LOVAG Certificate: | IT99056 |
| LR Certificate: | LR_12-70003 |
| RINA Certificate: | ELE060313XG/001 |
| RMRS Certificate: | RMRS_12-03683-315 |
| RoHS Information: | 2CMT2015-005436 |
| |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 203 mm |
| Package Level 1 Depth / Length: | 245 mm |
| Package Level 1 Height: | 188 mm |
| Package Level 1 Gross Weight: | 6.1 kg |
| Package Level 1 EAN: | 7320500213445 |
| |
| Object Classification Code: | Q |
| ETIM 4: | EC000066 - Magnet contactor, AC-switching |
| ETIM 5: | EC000066 - Magnet contactor, AC-switching |
| ETIM 6: | EC000066 - Power contactor, AC switching |
| ETIM 7: | EC000066 - Power contactor, AC switching |
| eClass: | V11.0 : 27371003 |
| UNSPSC: | 39121529 |
| IDEA Granular Category Code (IGCC): | 4755 >> Contactors |