A110-30-22 42V 50Hz / 42V 60Hz Contactor
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
| Extended Product Type: | A110-30-22-82 |
| Product ID: | 1SFL451001R8222 |
| EAN: | 7320500141540 |
| Catalog Description: | A110-30-22 42V 50Hz / 42V 60Hz Contactor |
| Long Description: | A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz |
| |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85364900 |
| Replacement Product ID (NEW): | 1SFL427001R1122 |
| Popular Downloads | |
| Data Sheet, Technical Information: | 1SBC100192C0206 |
| Instructions and Manuals: | 5309660-60 |
| Dimension Diagram: | 53540923-1 |
| |
| Product Net Width: | 90 mm |
| Product Net Depth / Length: | 156.5 mm |
| Product Net Height: | 148 mm |
| Product Net Weight: | 1.8 kg |
| |
| Number of Main Contacts NO: | 3 |
| Number of Main Contacts NC: | 0 |
| Number of Auxiliary Contacts NO: | 2 |
| Number of Auxiliary Contacts NC: | 2 |
| Rated Operational Voltage: | Main Circuit 1000 V |
| Rated Frequency (f): | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A |
| Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 160 |
| (690 V) 55 °C 145 | |
| (690 V) 70 °C 130 | |
| Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 110 A |
| (440 V) 55 °C 100 A | |
| (500 V) 55 °C 100 A | |
| (690 V) 55 °C 82 A | |
| (1000 V) 55 °C 30 A | |
| (380 / 400 V) 55 °C 110 A | |
| (220 / 230 / 240 V) 55 °C 110 | |
| Rated Operational Power AC-3 (Pe): | (415 V) 59 kW |
| (440 V) 59 kW | |
| (500 V) 59 kW | |
| (690 V) 75 kW | |
| (1000 V) 40 kW | |
| (380 / 400 V) 55 kW | |
| (220 / 230 / 240 V) 30 kW | |
| Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
| Short-Circuit Protective Devices: | gG Type Fuses 200 A |
| Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 175 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A | |
| Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A | |
| Maximum Electrical Switching Frequency: | (AC-1) 300 cycles per hour |
| (AC-2 / AC-4) 150 cycles per hour | |
| (AC-3) 300 cycles per hour | |
| Rated Operational Current DC-1 (Ie): | (110 V) 2 Poles in Series, 40 °C 160 A |
| (220 V) 3 Poles in Series, 40 °C 160 A | |
| Rated Operational Current DC-3 (Ie): | (110 V) 2 Poles in Series, 40 °C 160 A |
| (220 V) 3 Poles in Series, 40 °C 160 A | |
| Rated Operational Current DC-5 (Ie): | (110 V) 2 Poles in Series, 40 °C 160 A |
| (220 V) 3 Poles in Series, 40 °C 160 A | |
| Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp): | Main Circuit 8 kV |
| Mechanical Durability: | 10 million |
| Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
| Coil Operating Limits: | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc): | 50 Hz 42 V |
| 60 Hz 42 V | |
| Coil Consumption: | Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A | |
| Operate Time: | Between Coil De-energization and NC Contact Closing 7 ... 15 ms |
| Between Coil De-energization and NO Contact Opening 10 ... 18 ms | |
| Between Coil Energization and NC Contact Opening 7 ... 22 ms | |
| Between Coil Energization and NO Contact Closing 10 ... 25 ms | |
| Connecting Capacity Main Circuit: | Bar 30 mm² |
| Flexible with Cable End 2 x 6 ... 35 mm² | |
| Rigid 1 x 10 ... 95 mm² | |
| Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 2x0.75 ... 2.5 mm² | |
| Solid 2 x 1 ... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Connecting Terminals (delivered in open position) Main Poles: | M8 hexagon socket screw with single connector |
| Terminal Type: | Cable Clamp |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA: | Main Circuit 600 V |
| General Use Rating UL/CSA: | (600 V AC) 140 A |
| Horsepower Rating UL/CSA: | (200 V AC) Three Phase 30 hp |
| (208 V AC) Three Phase 30 hp | |
| (220 ... 240 V AC) Three Phase 40 hp | |
| (440 ... 480 V AC) Three Phase 75 hp | |
| (550 ... 600 V AC) Three Phase 100 hp | |
| |
| Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Maximum Operating Altitude Permissible: | 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27: | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 K40 |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 K40 | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 K40 | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 K40 | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 K40 | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 K40 | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 K40 | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 K40 | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 K40 | |
| RoHS Status: | Following EU Directive 2011/65/EU |
| |
| BV Certificate: | 07172/D0 BV |
| CB Certificate: | SE-69487 |
| CQC Certificate: | CQC2002010304008904 |
| CQC2009010304353526 | |
| CSA Certificate: | 314005 |
| Declaration of Conformity - CCC: | 2020980304001630 |
| 2020980304001078 | |
| Declaration of Conformity - CE: | 2CMT2015-005436 |
| DNV Certificate: | DNV_E-12191 |
| Environmental Information: | 1SFC101001D0201 |
| GL Certificate: | GL_99358-97HH |
| Instructions and Manuals: | 5309660-60 |
| LOVAG Certificate: | SE9723126-2 |
| LR Certificate: | LR_12-70027-E1 |
| RINA Certificate: | ELE060313XG/001 |
| RMRS Certificate: | RMRS_12-03683-315 |
| RoHS Information: | 2CMT2015-005436 |
| |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 170 mm |
| Package Level 1 Depth / Length: | 140 mm |
| Package Level 1 Height: | 170 mm |
| Package Level 1 Gross Weight: | 2 kg |
| Package Level 1 EAN: | 7320500141540 |
| |
| Object Classification Code: | Q |
| ETIM 4: | EC000066 - Magnet contactor, AC-switching |
| ETIM 5: | EC000066 - Magnet contactor, AC-switching |
| ETIM 6: | EC000066 - Power contactor, AC switching |
| ETIM 7: | EC000066 - Power contactor, AC switching |
| eClass: | V11.0 : 27371003 |
| UNSPSC: | 39121529 |
| IDEA Granular Category Code (IGCC): | 4755 >> Contactors |