Article: A16-30-10 264 V 60HZ CTC2000007R0003

Article: A16-30-10 264 V 60HZ CTC2000007R0003
A16-30-10 264 V 60HZ CTC2000007R0003 Contactor
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
| Extended Product Type: | A16-30-10 264 V 60HZ CTC2000007R0003 |
| Product ID: | 1SBL181001R9002 |
| EAN: | 3471522255921 |
| Catalog Description: | A16-30-10 264 V 60HZ CTC2000007R0003 Contactor |
| Long Description: | A16-30-10 264 V 60HZ CTC2000007R0003 Contactor |
| |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85364900 |
| |
| Product Net Width: | 44 mm |
| Product Net Depth / Length: | 74 mm |
| Product Net Height: | 74 mm |
| Product Net Weight: | 0.34 kg |
| |
| Number of Main Contacts NO: | 3 |
| Number of Main Contacts NC: | 0 |
| Number of Auxiliary Contacts NO: | 1 |
| Number of Auxiliary Contacts NC: | 0 |
| Rated Operational Voltage: | Main Circuit 690 V |
| Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 30 A |
| acc. to IEC 60947-5-1, q = 40 °C 16 A | |
| Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 30 |
| (690 V) 55 °C 27 | |
| (690 V) 70 °C 23 | |
| Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 17 A |
| (440 V) 55 °C 16 A | |
| (500 V) 55 °C 14 A | |
| (690 V) 55 °C 10 A | |
| (380 / 400 V) 55 °C 17 A | |
| (220 / 230 / 240 V) 55 °C 17 | |
| Rated Operational Power AC-3 (Pe): | (415 V) 9 kW |
| (440 V) 9 kW | |
| (500 V) 9 kW | |
| (690 V) 9 kW | |
| (380 / 400 V) 7.5 kW | |
| (220 / 230 / 240 V) 4 kW | |
| Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
| Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A | |
| Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
| (AC-2 / AC-4) 300 cycles per hour | |
| (AC-3) 1200 cycles per hour | |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc): | 60 Hz 264 V |
| Connecting Capacity Main Circuit: | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Connecting Capacity Auxiliary Circuit: | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
| Connecting Terminals (delivered in open position) Main Poles: | M 3.5 (+,-) pozidriv 2 screws with cable clamp |
| Terminal Type: | Screw Terminals |
| |
| Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C |
| Maximum Operating Altitude Permissible: | 3000 m |
| RoHS Status: | Following EU Directive 2011/65/EU |
| |
| CQC Certificate: | CQC2013010304615753 |
| CQC2018010304059156 | |
| CQC2004010309130463 | |
| CSA Certificate: | CSA_1041746 |
| Declaration of Conformity - CCC: | 2020980304001607 |
| 2020980304001616 | |
| 2020980304001229 | |
| Declaration of Conformity - CE: | 1SBD250801U1000 |
| EAC Certificate: | EAC_RU C-FR ME77 B03599 |
| RoHS Information: | 1SBD250801U1000 |
| |
| Package Level 1 Units: | 1 piece |
| Package Level 1 Width: | 78 mm |
| Package Level 1 Depth / Length: | 76 mm |
| Package Level 1 Height: | 47 mm |
| Package Level 1 Gross Weight: | 0.34 kg |
| Package Level 1 EAN: | 3471522255921 |
| Package Level 2 Units: | box 63 piece |
| Package Level 2 Width: | 300 mm |
| Package Level 2 Depth / Length: | 245 mm |
| Package Level 2 Height: | 308 mm |
| Package Level 2 Gross Weight: | 21.42 kg |
| Package Level 3 Units: | 1220 piece |
| |
| Object Classification Code: | Q |
| ETIM 6: | EC000066 - Power contactor, AC switching |
| ETIM 7: | EC000066 - Power contactor, AC switching |
| eClass: | V11.0 : 27371003 |