Article: DS201 C16 APR300

Article: DS201 C16 APR300
DS201 C16 APR300 Residual Current Circuit Breaker with Overcurrent Protection
We find the right product
for you
Official reseller
Expert engineering support
Configuration
):
General Information | |
Extended Product Type: | DS201 C16 APR300 |
Product ID: | 2CSR255480R3164 |
EAN: | 8012542659310 |
Catalog Description: | DS201 C16 APR300 Residual Current Circuit Breaker with Overcurrent Protection |
Long Description: | The DS201 series is a 1P+N RCBO in two-modules width for the protection of end user single-phase circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating and direct pulsating earth fault currents; protection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA). The APR type provides an optimal trade-off between safety and continuity of service, thanks to the resistance to unwanted trippings, offering good protection and isolation of resistive and inductive loads. |
| |
Standards: | IEC/EN 61009-1, IEC/EN 61009-2-1 |
Product Name: | Residual Current Circuit Breaker with Overcurrent Protection |
Tripping Characteristic: | C |
Type of Residual Current: | A type |
Rated Voltage (Ur): | 230 V |
Rated Operational Voltage: | 230 … 240 V AC |
Rated Insulation Voltage (Ui): | 500 V |
Test Voltage (Ut): | 110 ... 264 V |
Dielectric Test Voltage: | 2.5 kV |
Primary Rated Impulse Withstand Voltage: | 4 kV |
Input Voltage Type: | AC |
Rated Current (In): | 16 A |
Rated Residual Operating Current (IΔn): | 6000 A |
Rated Residual Current: | 300 mA |
Rated Short-Circuit Capacity (Icn): | 6 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | 10 kA |
Rated Residual Breaking Capacity (IΔm): | EN 61009-1 6000 A |
IEC 61009-1 6000 A | |
Rated Conditional Short-Circuit Current (Inc): | 10 kA |
Rated Service Short-Circuit Breaking Capacity (Ics): | 7.5 kA |
Maximum Surge Current: | 3 kA |
Frequency (f): | 50/60 Hz |
Rated Frequency (f): | 50/60 Hz |
Power Loss: | 3.3 W |
Power Supply Connection: | Arbitrary |
Contact Position Indication: | Red ON / Green OFF |
Energy Limiting Class: | 3 |
Electrical Endurance: | 10000 cycle |
Mechanical Endurance (N | |
endu | 20000 cycle |
Number of Poles: | 2 |
Number of Protected Poles: | 1 |
Number of Modular Spacings per DIN Rail: | 2 |
Fault Indication: | Blue flag on toggle |
Operating Characteristic: | Instantaneous (APR High Immunity) |
Overvoltage Category: | III |
Position of Neutral Terminals: | Right |
Tightening Torque: | 2.8 N·m |
Accessory Type: | Auxiliary contact |
Signal contact / auxiliary contact | |
Shunt trip | |
Auxiliary contact for bottom fitting | |
Undervoltage release | |
Overvoltage release | |
Motor operating device | |
Actuator Type: | Toggle - Insulation group II, Black RAL 9005,sealable in ON-OFF positions |
Housing Type: | Insulation group I - II, RAL 7035 |
Mounting Type: | on DIN rail EN 60715 (35mm) by means of mounting clip |
Release Type: | C |
Screw Terminal Type: | Failsafe Bi-directional Cylinder-lift Terminal |
Mounting Position: | Any |
Accessories Available: | Yes |
Surge Immunity acc. to IEC 61000-4-5: | 3000 A |
Number of Batteries: | 0 |
Cable Size: | 25 mm² |
Connecting Capacity: | Busbar 10 ... 10 mm² |
Stranded 0.75 ... 25 mm² | |
Flexible with Ferrule 0.75 ... 16 mm² | |
Flexible 0.75 ... 16 mm² | |
Wire Stripping Length: | 12 mm |
Terminal Type: | Screw Terminals |
| |
Ambient Temperature: | -25...55 °C |
Ambient Air Temperature: | Operation -25...55 °C |
Reference Ambient Air Temperature: | 30 °C |
Degree of Protection: | Terminals IP20 |
Housing IP40 | |
Pollution Degree: | 2 |
Environmental Conditions: | 28 cycles |
with 55 °C / 90-96 % | |
and 25 °C / 95-100 % | |
Resistance to Vibrations acc. to IEC 60068-2-6: | 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz |
Resistance to Shock acc. to IEC 60068-2-27: | 25g / 2 shocks / 13 ms |
Environmental Information: | 2CSC422002K2701 |
Technical UL/CSA | |
Short-Circuit Current Rating (SCCR): | 0.3 A |
| |
Width in Number of Modular Spacings: | 2 |
Product Net Width: | 0.035 m |
Product Net Height: | 0.085 m |
Product Net Depth / Length: | 0.069 m |
Product Net Weight: | 0.200 kg |
Built-In Depth (t2): | 69 mm |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 40 mm |
Package Level 1 Height: | 106 mm |
Package Level 1 Depth / Length: | 80 mm |
Package Level 1 Gross Weight: | 225 g |
Package Level 1 EAN: | 8012542659310 |
Package Level 2 Units: | box 5 piece |
Package Level 2 Width: | 200 mm |
Package Level 2 Height: | 106 mm |
Package Level 2 Depth / Length: | 80 mm |
Package Level 2 Gross Weight: | 1125 g |
Package Level 2 EAN: | 8012542041818 |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85363010 |
E-Number (Sweden): | 2100513 |
Country of Origin: | Italy (IT) |
Selling Unit of Measure: | piece |
| |
ABS Certificate: | 9AKK107991A2823 |
CB Certificate: | 9AKK107492A6060 |
CCC Certificate: | 9AKK107492A6067 |
Declaration of Conformity - CE: | 9AKK106713A5588 |
DNV GL Certificate: | 9AKK107680A3457 |
9AKK107680A3456 | |
EAC Certificate: | 9AKK107492A6071 |
9AKK107991A7755 | |
Environmental Information: | 2CSC422002K2701 |
GOST Certificate: | 9AKK107992A1640 |
Instructions and Manuals: | 9AKK107492A6006 |
KEMA Certificate: | 9AKK107492A6076 |
ÖVE Certificate: | 9AKK107492A6085 |
RMRS Certificate: | 9AKK107680A3454 |
9AKK107680A3455 | |
RoHS Information: | 2CSC422002K2701 |
VDE Certificate: | 9AKK107492A6092 |
Popular Downloads | |
Data Sheet, Technical Information: | 9AKK107492A6187 |
Instructions and Manuals: | 9AKK107492A6006 |
EPLAN Macro: | 9AKK107680A0597 |
| |
ETIM 6: | EC000905 - Earth leakage circuit breaker |
ETIM 7: | EC000905 - Earth leakage circuit breaker |
ETIM 8: | EC000905 - Earth leakage circuit breaker |
EPLAN Catalog Tree: | Electrical engineering / Protection devices / Ground fault current circuit breaker |
WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
WEEE B2C / B2B: | Business To Consumer |
CN8: | 85363010 |
Object Classification Code: | F |
Accessories |