Extended Product Type: | NSL22ES-86 |
Product ID: | 1SBH103004R8622 |
EAN: | 3471523056862 |
Catalog Description: | NSL22ES-86 110VDC Contactor Relay |
Long Description: | NSL... contactor relays are used for switching auxiliary circuits and control circuits. The NSL..S contactor relays are the spring terminal version of the NSL... range. - Poles and auxiliary contacts blocks: 4-pole contactor relays, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor relay side) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NSL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs. |
| |
Minimum Order Quantity: | 40 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Instructions and Manuals: | 1SBC101020M9701 |
| |
Product Net Width: | 45 mm |
Product Net Depth / Length: | 72.5 mm |
Product Net Height: | 68 mm |
Product Net Weight: | 0.28 kg |
| |
Number of Auxiliary Contacts NO: | 2 |
Number of Auxiliary Contacts NC: | 2 |
Standards: | IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14 |
Rated Operational Voltage: | Auxiliary Circuit 690 V |
Main Circuit 690 V | |
Rated Frequency (f): | Auxiliary Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-5-1, q = 40 °C 10 A |
Rated Operational Current AC-15 (Ie): | (220 / 240 V) 4 A |
(24 / 127 V) 6 A | |
(400 / 440 V) 3 A | |
(500 V) 2 A | |
(690 V) 2 A | |
Rated Short-time Withstand Current (Icw): | for 0.1 s 140 A |
for 1 s 100 A | |
Maximum Electrical Switching Frequency: | (AC-15) 1200 cycles per hour |
(DC-13) 900 cycles per hour | |
Rated Operational Current DC-13 (Ie): | (110 V) 0.55 A / 60 W |
(220 V) 0.27 A / 60 W | |
(125 V) 0.55 A / 69 W | |
(24 V) 6 A / 144 W | |
(250 V) 0.27 A / 68 W | |
(48 V) 2.8 A / 134 W | |
(72 V) 1 A / 72 W | |
Rated Insulation Voltage (Ui): | acc. to UL/CSA 600 V |
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V | |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | DC Operation 110 V |
Operate Time: | Between Coil De-energization and NC Contact Closing 15 ... 20 ms |
Between Coil De-energization and NO Contact Opening 13 ... 17 ms | |
Between Coil Energization and NC Contact Opening 31 ... 53 ms | |
Between Coil Energization and NO Contact Closing 36 ... 59 ms | |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² | |
Rigid 1/2x 0.75 ... 2.5 mm² | |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² | |
Rigid 1/2x 0.75 ... 2.5 mm² | |
Wire Stripping Length: | Auxiliary Circuit 10 mm |
Control Circuit 10 mm | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
Terminal Type: | Spring Terminals |
| |
Ambient Air Temperature: | Close to Contactor for Storage -60 ... +80 °C |
Near Contactor for Operation in Free Air -40 ... +70 °C | |
Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5 ... 300 Hz 3 g Closed position / 2 g Open position |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: A 20 g |
Closed, Shock Direction: B1 15 g | |
Closed, Shock Direction: C1 19 g | |
Closed, Shock Direction: C2 14 g | |
Open, Shock Direction: A 10 g | |
Open, Shock Direction: B1 5 g | |
Open, Shock Direction: C1 8 g | |
Open, Shock Direction: C2 8 g | |
Shock Direction: B2 10 g | |
RoHS Status: | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| |
CB Certificate: | CB_CN_32453 |
CCC Certificate: | CCC_2007010305248106 |
CQC Certificate: | CQC2007010305248106 |
Declaration of Conformity - CCC: | 2020980304001219 |
Declaration of Conformity - CE: | 1SBD250016U1000 |
Declaration of Conformity - UKCA: | 1SBD250051U1000 |
Environmental Information: | 1SBD250161E1000 |
GOST Certificate: | GOST_POCCCNME77B07821.pdf |
Instructions and Manuals: | 1SBC101020M9701 |
RoHS Information: | 1SBD251008E1000 |
UL Certificate: | UL_220108-E312527A |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 78 mm |
Package Level 1 Depth / Length: | 80 mm |
Package Level 1 Height: | 48 mm |
Package Level 1 Gross Weight: | 0.28 kg |
Package Level 1 EAN: | 3471523056862 |
Package Level 2 Units: | 40 piece |
Package Level 2 Width: | 250 mm |
Package Level 2 Depth / Length: | 315 mm |
Package Level 2 Height: | 195 mm |
Package Level 2 Gross Weight: | 11.2 kg |
Package Level 3 Units: | 960 piece |
| |
Object Classification Code: | K |
ETIM 4: | EC000196 - Contactor relay |
ETIM 5: | EC000196 - Contactor relay |
ETIM 6: | EC000196 - Contactor relay |
ETIM 7: | EC000196 - Contactor relay |
UNSPSC: | 39121529 |