Article: TF42-13B

Article: TF42-13B

TF42-13B Thermal Overload Relay
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration




























































General Information
Extended Product Type: TF42-13B
Product ID: 1SAZ741201R1045
EAN: 4013614517174
Catalog Description: TF42-13B Thermal Overload Relay
Long Description: The TF42-B thermal overload relays are economic electromechanical protection devices for the main circuit, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.They offer a reliable protection for motors in the event of overload or phase failure. The devices have tripclass 10.The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flowsthrough the bimetal tripping elements and heats them directly and indirectly. In case of an overload (overcurrent), the bimetal elements bent as a result of the heating. This leads to a release of the relay and achange of the contacts switching position (95-96 / 97-98).– Manual or automatic reset selectable– Phase loss sensitive acc. to IEC/EN 60947-4-1– TEST and STOP function – Trip indication on the front– Temperature compensation– Suitable for three- and single-phase applications– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Data Sheet, Technical Information: 2CDC106023D0201
Data Sheet, Technical Information (Part 2): 1SAC200122W0001
Data Sheet, Technical Information (Part 3): 1SAZ700504
Instructions and Manuals: 2CDC106022M6802

Dimensions
Product Net Width: 45 mm
Product Net Height: 88.3 mm
Product Net Depth / Length: 70.5 mm
Product Net Weight: 0.13 kg

Technical
Setting Range: 10 ... 13 A
Rated Operational Voltage: Auxiliary Circuit 600 V AC/DC
Main Circuit 690 V AC
Rated Operational Current (Ie): 13 A
Rated Operational Current AC-3 (Ie): 13 A
Rated Frequency (f): Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp): Auxiliary Circuit 6 kV
Main Circuit 6 kV
Rated Insulation Voltage (Ui): 690 V
Number of Poles: 3
Number of Auxiliary Contacts NC: 1
Number of Auxiliary Contacts NO: 1
Number of Protected Poles: 3
Conventional Free-air Thermal Current (Ith): Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 4 A
Main Circuit 0 A
Rated Operational Current AC-15 (Ie): (120 V) NC 3 A
(120 V) NO 0.75 A
(240 V) NC 3 A
(240 V) NO 0.75 A
(400 V) NC 0.75 A
(400 V) NO 0.75 A
(500 V) NC 0.75 A
(500 V) NO 0.75 A
Rated Operational Current DC-13 (Ie): (125 V) NC 0.55 A
(125 V) NO 0.55 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.27 A
(250 V) NO 0.27 A
(500 V) NC 0.15 A
(500 V) NO 0.15 A
(60 V) NC 0.55 A
(60 V) NO 0.55 A
Degree of Protection: IP20
Pollution Degree: 3
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 1 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm²
Flexible 1/2x 0.75 ... 4 mm²
Rigid 1/2x 0.75 ... 4 mm²
Tightening Torque: Auxiliary Circuit 1 ... 1.2 N·m
Main Circuit 2.5 ... 2.7 N·m
Wire Stripping Length: Auxiliary Circuit 9 mm
Main Circuit 12 mm
Recommended Screw Driver: Main Circuit Pozidriv 2
Power Loss: at Rated Operating Conditions per Pole 1.3 W
Suitable For: AF09ZB
AF09B
AF12ZB
AF12B
AF16ZB
AF16B
AF26ZB
AF26B
AF30ZB
AF30B
AF38ZB
AF38B
Standards: CSA 22.2 No. 14
IEC 60077-1 (applicable parts)
IEC 60077-2 (applicable parts)
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Ampere Rating UL/CSA: 13 A
Contact Rating UL/CSA: (NC:) B600
(NC:) Q600
(NO:) Q600
(NO:) D300
Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 18-10 AWG
Stranded 1/2x 18-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA: Flexible 1/2x 18-12 AWG
Stranded 1/2x 18-12 AWG
Tightening Torque UL/CSA: Auxiliary Circuit 9 ... 11 in·lb
Main Circuit 13 ... 22 in·lb

Environmental
Ambient Air Temperature: Operation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation: Yes
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 3 ... 150 Hz
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
CQC Certificate: CQC2011010309464423
Declaration of Conformity - CCC: 2020980304001788
Declaration of Conformity - CE: 1SAD938505-0199
Declaration of Conformity - UKCA: 1SAD938501-1199
Environmental Information: 1SAC200057H0009
Instructions and Manuals: 2CDC106022M6802
RoHS Information: 1SAD938501-0199
UL Certificate: cUL_E48139

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 48 mm
Package Level 1 Height: 92 mm
Package Level 1 Depth / Length: 78 mm
Package Level 1 Gross Weight: 0.145 kg
Package Level 1 EAN: 4013614517174
Package Level 2 Units: 48 piece
Package Level 2 Width: 280 mm
Package Level 2 Height: 210 mm
Package Level 2 Depth / Length: 395 mm
Package Level 2 Gross Weight: 7.346 kg
Package Level 2 EAN: 4013614517396

Classifications
Object Classification Code: F
ETIM 5: EC000106 - Thermal overload relay
ETIM 6: EC000106 - Thermal overload relay
ETIM 7: EC000106 - Thermal overload relay
eClass: V11.0 : 27371501
UNSPSC: 39121520
IDEA Granular Category Code (IGCC): 5364 >> Overload relay
Accessories