Article: TAL26-30-01RT 17-32V DC

Article: TAL26-30-01RT 17-32V DC
TAL26-30-01RT 17-32V DC Contactor
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | TAL26-30-01RT 17-32V DC |
Product ID: | 1SBL243060R5101 |
EAN: | 3471522363213 |
Catalog Description: | TAL26-30-01RT 17-32V DC Contactor |
Long Description: | TAL26 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The TAL..RT contactors are the Ring Tongue terminal version of the TAL... range. The TAL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. TAL... contactors are fitted with low consumption DC coils and offer a large coil voltage range. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SNC001003C0202 |
Instructions and Manuals: | 1SBC101006M5501 |
Dimension Diagram: | FPTE307905 |
| |
Product Net Width: | 54 mm |
Product Net Depth / Length: | 110.6 mm |
Product Net Height: | 90 mm |
Product Net Weight: | 0.75 kg |
| |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 0 |
Number of Auxiliary Contacts NC: | 1 |
Rated Operational Voltage: | Auxiliary Circuit 690 V |
Main Circuit 690 V | |
Rated Frequency (f): | Supply Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 45 A |
acc. to IEC 60947-5-1, q = 40 °C 16 A | |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 45 |
(690 V) 55 °C 40 | |
(690 V) 70 °C 32 | |
Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 26 A |
(440 V) 55 °C 26 A | |
(500 V) 55 °C 22 A | |
(690 V) 55 °C 13 A | |
(380 / 400 V) 55 °C 26 A | |
(220 / 230 / 240 V) 55 °C 26 | |
Rated Operational Power AC-3 (Pe): | (415 V) 11 kW |
(440 V) 15 kW | |
(500 V) 15 kW | |
(690 V) 11 kW | |
(380 / 400 V) 11 kW | |
(220 / 230 / 240 V) 6.5 kW | |
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(380 / 400 V) 3 A | |
Short-Circuit Protective Devices: | Auxiliary Circuit - gG Type Fuses 10 A |
gG Type Fuses 50 A | |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A | |
Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
(AC-2 / AC-4) 300 cycles per hour | |
(AC-3) 1200 cycles per hour | |
Rated Operational Current DC-13 (Ie): | (24 V) 6 A / 144 W |
(48 V) 2.8 A / 134 W | |
(72 V) 2 / 144 A | |
(125 V) 1.1 / 138 A | |
(250 V) 0.55 / 138 A | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Mechanical Durability: | 10 million |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | DC Operation 17 ... 32 V |
Coil Consumption: | Holding DC (Umin / Umax) 2.7 / 9 W |
Pull-in DC (Umin / Umax) 2.7 / 9 W | |
Operate Time: | Between Coil De-energization and NC Contact Closing 18 ... 28 ms |
Between Coil De-energization and NO Contact Opening 12 ... 18 ms | |
Between Coil Energization and NC Contact Opening 25 ... 75 ms | |
Between Coil Energization and NO Contact Closing 55 ... 110 ms | |
Connecting Capacity Main Circuit: | Flexible with Cable Lug 1 ... 6 mm² |
Rigid Cable 1 ... 6 mm² | |
Connecting Capacity Auxiliary Circuit: | Rigid or Flexible with Cable Lug 0.75 ... 2.5 mm² |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
Connecting Terminals (delivered in open position) Main Poles: | M 4 (+,-) pozidriv 2 screw with conic washer |
Terminal Type: | Ring-Tongue Terminals |
Technical UL/CSA | |
General Use Rating UL/CSA: | (600 V AC) 40 A |
| |
Ambient Air Temperature: | Close to Contactor without Thermal O/L Relay -40 ... 55 °C |
Close to Contactor for Storage -60 ... +80 °C | |
Climatic Withstand: | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
Maximum Operating Altitude Permissible: | Without Derating 3000 m |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: A 20 g |
Closed, Shock Direction: B1 15 g | |
Closed, Shock Direction: C1 20 g | |
Closed, Shock Direction: C2 14 g | |
Open, Shock Direction: A 10 g | |
Open, Shock Direction: B1 5 g | |
Open, Shock Direction: C1 8 g | |
Open, Shock Direction: C2 8 g | |
Shock Direction: B2 10 g | |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CB Certificate: | CB_FR3460_60022335_515371G |
CCC Certificate: | CCC_2004010304112231 |
CQC Certificate: | CQC2004010304112231 |
CSA Certificate: | CSA_1033838_LR056745 |
Declaration of Conformity - CCC: | 2020980304001611 |
Declaration of Conformity - CE: | 1SBD250804U1000 |
EAC Certificate: | EAC_RU C-FR ME77 B01010 |
Environmental Information: | 1SBD250122E1002 |
GOST Certificate: | GOST_POCCFRME77B07175 |
Instructions and Manuals: | 1SBC101006M5501 |
RoHS Information: | 1SBD250806U1000 |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 100 mm |
Package Level 1 Depth / Length: | 134 mm |
Package Level 1 Height: | 62 mm |
Package Level 1 Gross Weight: | 0.75 kg |
Package Level 1 EAN: | 3471522363213 |
Package Level 2 Units: | box 20 piece |
Package Level 2 Gross Weight: | 15 kg |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
eClass: | V11.0 : 27371018 |
UNSPSC: | 39121529 |