Article: VBC7A-30-01-P-07

Article: VBC7A-30-01-P-07
VBC7A-30-01-P-07 Mini Rev.Contactor 12VDC
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | VBC7A-30-01-P-07 |
Product ID: | GJL1313919R0017 |
EAN: | 4013614404368 |
Catalog Description: | VBC7A-30-01-P-07 Mini Rev.Contactor 12VDC |
Long Description: | The VBC7A-30-01-P mini reversing contactor is a compact 3 pole contactor with 1 auxiliary contact, soldering pins and mechanical interlock and safety blocking. They are ideally suited for applications where reliability is a must and space is at a premium. Mini reversing contactors are used in residential buldings, commercial buildings and industrial applications for the control of three-phase motor loads up to 5.5 kW (AC-3). Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail mounting. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85365080 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100214C0201 |
Instructions and Manuals: | 2CDC102046M6801 |
Dimension Diagram: | GJL1200449F0001 |
| |
Product Net Width: | 96.5 mm |
Product Net Height: | 57.5 mm |
Product Net Depth / Length: | 51.5 mm |
Product Net Weight: | 0.345 kg |
| |
Number of Poles: | 3 |
Rated Operational Voltage: | Auxiliary Circuit 690 V AC |
Auxiliary Circuit 250 V DC | |
Main Circuit 690 V AC | |
Main Circuit 220 V DC | |
Rated Frequency (f): | Main Circuit 60 Hz |
Main Circuit 50 Hz | |
Main Circuit DC | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 6 kV |
Rated Insulation Voltage (Ui): | 690 V |
acc. to UL/CSA 600 V | |
Number of Main Contacts NC: | 0 |
Number of Main Contacts NO: | 3 |
Rated Operational Current AC-1 (Ie): | (220 / 240 V) 40 °C 12 A |
(220 / 240 V) 55 °C 12 A | |
(380 / 440 V) 40 °C 12 A | |
(380 / 440 V) 55 °C 12 A | |
(690 V) 40 °C 6 A | |
(690 V) 55 °C 6 A | |
Rated Operational Power AC-3 (Pe): | (230 V) Three Phase 3 kW |
(400 V) Three Phase 5.5 kW | |
(500 V) Three Phase 5.5 kW | |
(690 V) Three Phase, NO 3 kW | |
Rated Short-time Withstand Current Low Voltage (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A |
Number of Auxiliary Contacts NC: | 1 |
Number of Auxiliary Contacts NO: | 0 |
Conventional Free-air Thermal Current (Ith): | Main Circuit 12 A |
Rated Control Circuit Voltage (Uc): | 12 V DC |
Coil Operating Limits: | (acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
Degree of Protection: | Main Circuit Terminals IP20 |
Pollution Degree: | 3 |
Mechanical Durability: | 10000000 cycle |
Minimum Switching Capacity: | Auxiliary Circuit 17 V |
Auxiliary Circuit 5 mA | |
Maximum Electrical Switching Frequency: | (AC-1) 300 cycles per hour |
(AC-15) 600 cycles per hour | |
(AC-3) 600 cycles per hour | |
(DC-1) 600 cycles per hour | |
(DC-13) 600 cycles per hour | |
(DC-3) 600 cycles per hour | |
Mounting on DIN Rail: | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | |
Power Loss: | at Rated Operating Conditions AC-1 per Pole 1.4 W |
Standards: | IEC/EN 60947-1 |
IEC/EN 60947-4-1 | |
IEC/EN 60947-5-1 | |
UL 60947-1 | |
UL 60947-4-1 | |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Full Load Amps Motor Use: | (115 V AC) Single Phase 13.8 A |
(200 V AC) Three Phase 7.8 A | |
(220 ... 240 V AC) Three Phase 9.6 A | |
(230 V AC) Single Phase 10 A | |
(440 ... 480 V AC) Three Phase 7.6 A | |
(550 ... 600 V AC) Three Phase 6.1 A | |
Horsepower Rating UL/CSA: | (115 V AC) Single Phase 0.75 Hp |
(200 V AC) Three Phase 2 Hp | |
(220 ... 240 V AC) Three Phase 3 Hp | |
(230 V AC) Single Phase 1.5 Hp | |
(440 ... 480 V AC) Three Phase 5 Hp | |
(550 ... 600 V AC) Three Phase 5 Hp | |
General Use Rating UL/CSA: | (600 V AC) 12 A |
Contact Rating UL/CSA: | A600 |
| |
Ambient Air Temperature: | Operation -20 ... +55 °C |
Storage -40 ... +80 °C | |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 15g |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5g / 5 ... 150 Hz |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CB Certificate: | 1SAA938000-2002 |
CQC Certificate: | CQC2003010304064033 |
cURus Certificate: | cUL_E191658 |
Declaration of Conformity - CCC: | 2020980304001854 |
Declaration of Conformity - CE: | 1SAD938517-0001 |
Declaration of Conformity - UKCA: | 1SAD938501-1001 |
DNV GL Certificate: | 1SAA938000-0306 |
EAC Certificate: | 1SAA920000-2702 |
Environmental Information: | 1SAC200068H0009 |
Instructions and Manuals: | 2CDC102046M6801 |
KC Certificate: | 1SAA938000-1501 |
RMRS Certificate: | 1SAA938000-0704 |
RoHS Information: | 1SAD938517-0001 |
| |
Package Level 1 Units: | 5 piece |
Package Level 1 Width: | 115 mm |
Package Level 1 Height: | 64 mm |
Package Level 1 Depth / Length: | 280 mm |
Package Level 1 Gross Weight: | 1.795 kg |
Package Level 1 EAN: | 4013614419966 |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000010 - Starter combination |
ETIM 6: | EC000010 - Combination of contactors |
ETIM 7: | EC000010 - Combination of contactors |
eClass: | V11.0 : 27371009 |
UNSPSC: | 39121529 |