Article: S804S-UCK50-R

We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
| Extended Product Type: | S804S-UCK50-R |
| Product ID: | 2CCS864002R1577 |
| EAN: | 7612271208851 |
| Catalog Description: | S804S-UCK50-R High Performance MCB |
| Long Description: | S804S-UCK50-R 4 Poles UCB Characteristic 50A 50kA 750VDC Ringlug |
| |
| Standards: | IEC/EN 60947-2 |
| Product Name: | High Performance MCB |
| Tripping Characteristic: | UC-K |
| Rated Voltage (Ur): | 750 V |
| Rated Operational Voltage: | 1000 V DC |
| Rated Insulation Voltage (Ui): | acc. to IEC/EN 60664-1 1000 V |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Input Voltage Type: | DC |
| Rated Current (In): | 50 A |
| Rated Operational Current (Ie): | 50 A |
| Rated Short-Circuit Capacity (Icn): | (400 V) 40 kA |
| (230 V) 40 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (1000 V DC) 50 kA |
| Rated Conditional Short-Circuit Current (Inc): | (230 V) 50 kA |
| (400 V) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (750 V DC) 50 kA |
| Frequency (f): | 0...0 Hz |
| Rated Frequency (f): | 0 ... 0 Hz |
| Power Loss: | 17.2 W |
| at Rated Operating Conditions per Pole 4.3 W | |
| Contact Position Indication: | ON / OFF / TRIP |
| Energy Limiting Class: | 3 |
| Number of Poles: | 4 |
| Number of Protected Poles: | 4 |
| Overvoltage Category: | III |
| Release Type: | K |
| Actuator Marking: | I / O |
| Options Provided: | Universal current |
| Ringlug terminal | |
| Accessories Available: | Yes |
| Connecting Capacity: | Rigid 0 ... 50 mm² |
| Flexible 0 ... 70 mm² | |
| |
| Ambient Temperature: | -25...60 °C |
| Ambient Air Temperature: | Operation -25...60 °C |
| Degree of Protection: | IP20 |
| Pollution Degree: | 2 |
| Environmental Conditions: | Damp Heat Cyclic acc. to IEC 60068-2-30 410 + 12 cycle |
| Damp Heat Cyclic acc. to IEC 60068-2-30 55°C @ 90-96 % | |
| Damp Heat Cyclic acc. to IEC 60068-2-30 25°C @ 90-100 % | |
| Dry Heat Test B acc. to IEC 60068-2-2 16 hours @ 55 °C | |
| Dry Heat Test B acc. to IEC 60068-2-2 2 hours @ 70 °C | |
| RoHS Status: | Following EU Directive 2011/65/EU |
| Environmental Information: | 2CCY413207D0203 |
| |
| Width in Number of Modular Spacings: | 4 |
| Product Net Width: | 108 mm |
| Product Net Height: | 142 mm |
| Product Net Depth / Length: | 82.5 mm |
| Product Net Weight: | 980 g |
| Product Net Length: | 108 mm |
| Size: | 4 modules |
| Built-In Depth (t2): | 82.5 mm |
| |
| Package Level 1 Units: | box 1 piece |
| Package Level 1 Width: | 152 mm |
| Package Level 1 Height: | 99 mm |
| Package Level 1 Depth / Length: | 111 mm |
| Package Level 1 Gross Weight: | 1030 g |
| Package Level 1 EAN: | 7612271208851 |
| |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362010 |
| Country of Origin: | Switzerland (CH) |
| Selling Unit of Measure: | piece |
| |
| Declaration of Conformity - CE: | 2CCC005084D0202 |
| Environmental Information: | 2CCY413207D0203 |
| Instructions and Manuals: | 2CCC413016M0008 |
| RoHS Information: | 2CCC005084D0202, 9AKK107680A3903 |
| Popular Downloads | |
| Data Sheet, Technical Information: | 2CCC413003C0208 |
| Instructions and Manuals: | 2CCC413016M0008 |
| Dimension Diagram: | 2CCC413003C0201 |
| |
| ETIM 6: | EC000042 - Miniature circuit breaker (MCB) |
| ETIM 7: | EC000042 - Miniature circuit breaker (MCB) |
| ETIM 8: | EC000042 - Miniature circuit breaker (MCB) |
| WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B: | Business To Business |
| CN8: | 85362020 |
| Object Classification Code: | F |