Article: ASL16-30-32-81

Article: ASL16-30-32-81

ASL16-30-32-81 24VDC Contactor
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration







































































General Information
Extended Product Type: ASL16-30-32-81
Product ID: 1SBL123001R8132
EAN: 3471523061811
Catalog Description: ASL16-30-32-81 24VDC Contactor
Long Description: ASL16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The AS... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact, with a non-removable front-mounted 2 N.O. + 2 N.C. auxiliary contact block (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor side. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Instructions and Manuals: 1SBC101020M9701

Dimensions
Product Net Width: 45 mm
Product Net Depth / Length: 100.2 mm
Product Net Height: 68 mm
Product Net Weight: 0.32 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 3
Number of Auxiliary Contacts NC: 2
Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 25 A
acc. to IEC 60947-5-1, q = 40 °C 10 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 24 A
(690 V) 60 °C 20 A
(690 V) 70 °C 16 A
Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 15.7 A
(380 / 400 V) 60 °C 15.5 A
(415 V) 60 °C 15.5 A
(440 V) 60 °C 13.6 A
(500 V) 60 °C 12.5 A
(690 V) 60 °C 9 A
Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 4 kW
(400 V) 7.5 kW
(415 V) 7.5 kW
(440 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 124 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 24 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 75 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie): (110 V) 0.55 A / 60 W
(220 V) 0.27 A / 60 W
(125 V) 0.55 A / 69 W
(24 V) 6 A / 144 W
(250 V) 0.27 A / 68 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): DC Operation 24 V
Operate Time: Between Coil De-energization and NC Contact Closing 15 ... 20 ms
Between Coil De-energization and NO Contact Opening 13 ... 17 ms
Between Coil Energization and NC Contact Opening 31 ... 53 ms
Between Coil Energization and NO Contact Closing 36 ... 59 ms
Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping Length: Auxiliary Circuit 9 mm
Control Circuit 9 mm
Main Circuit 9 mm
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type: Screw Terminals
Technical UL/CSA
General Use Rating UL/CSA: (600 V AC) 20 A
Horsepower Rating UL/CSA: (120 V AC) Single Phase 3/4 Hp
(240 V AC) Single Phase 2 Hp
(200 ... 208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Tightening Torque UL/CSA: Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 9 in·lb

Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Climatic Withstand: Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible: 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 3 g Closed position / 2 g Open position
Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 10 g
Closed, Shock Direction: C1 20 g
Closed, Shock Direction: C2 20 g
Open, Shock Direction: B1 5 g
Open, Shock Direction: C1 9 g
Open, Shock Direction: C2 14 g
Shock Direction: A 20 g
Shock Direction: B2 15 g

Certificates and Declarations (Document Number)
CB Certificate: CB_CN13475-M1
CCC Certificate: CCC_2007010309251577
CQC Certificate: CQC2007010309251577
Declaration of Conformity - CCC: 2020980304001224
Declaration of Conformity - CE: 1SBD250014U1000
Declaration of Conformity - UKCA: 1SBD250049U1000
Environmental Information: 1SBD250155E1000
GOST Certificate: GOST_POCCCNME77B07822.pdf
Instructions and Manuals: 1SBC101020M9701
RoHS Information: 1SBD251001E1001
UL Certificate: UL_20120917-E312527-1-1
UL Listing Card: UL_E312527

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 72 mm
Package Level 1 Depth / Length: 115 mm
Package Level 1 Height: 48 mm
Package Level 1 Gross Weight: 0.32 kg
Package Level 1 EAN: 3471523061811
Package Level 2 Units: 32 piece
Package Level 2 Width: 250 mm
Package Level 2 Depth / Length: 195 mm
Package Level 2 Height: 315 mm
Package Level 2 Gross Weight: 10.24 kg
Package Level 3 Units: 768 piece

Classifications
Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4755 >> Contactors