Article: AS12-30-32S-26

Article: AS12-30-32S-26

AS12-30-32S-26 230V50/60HZ Contactor
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration



































































General Information
Extended Product Type: AS12-30-32S-26
Product ID: 1SBL111004R2632
EAN: 3471523067264
Catalog Description: AS12-30-32S-26 230V50/60HZ Contactor
Long Description: AS12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The AS..S contactors are the spring terminal version of the AS... range. The AS... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact, with a non-removable front-mounted 2 N.O. + 2 N.C. auxiliary contact block (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor side. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.

Ordering
Minimum Order Quantity: 32 piece
Customs Tariff Number: 85364900
Popular Downloads
Instructions and Manuals: 1SBC101020M9701

Dimensions
Product Net Width: 45 mm
Product Net Depth / Length: 110.7 mm
Product Net Height: 68 mm
Product Net Weight: 0.26 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 3
Number of Auxiliary Contacts NC: 2
Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 22 A
acc. to IEC 60947-5-1, q = 40 °C 10 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 22 A
(690 V) 60 °C 17 A
(690 V) 70 °C 14 A
Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 12 A
(380 / 400 V) 60 °C 12 A
(415 V) 60 °C 12 A
(440 V) 60 °C 11 A
(500 V) 60 °C 11 A
(690 V) 60 °C 7 A
Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 3 kW
(400 V) 5.5 kW
(415 V) 5.5 kW
(440 V) 5.5 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 124 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 22 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 75 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie): (110 V) 0.55 A / 60 W
(220 V) 0.27 A / 60 W
(125 V) 0.55 A / 69 W
(24 V) 6 A / 144 W
(250 V) 0.27 A / 68 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 230 V
60 Hz 230 V
Operate Time: Between Coil De-energization and NC Contact Closing 7 ... 22 ms
Between Coil De-energization and NO Contact Opening 5 ... 19 ms
Between Coil Energization and NC Contact Opening 6 ... 18 ms
Between Coil Energization and NO Contact Closing 9 ... 24 ms
Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping Length: Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 10 mm
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type: Spring Terminals
Technical UL/CSA
General Use Rating UL/CSA: (600 V AC) 12 A
Horsepower Rating UL/CSA: (120 V AC) Single Phase 1/2 Hp
(240 V AC) Single Phase 1.5 Hp
(200 ... 208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 7.5 Hp
(550 ... 600 V AC) Three Phase 10 Hp

Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Climatic Withstand: Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible: 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 3 g Closed position / 2 g Open position
Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 10 g
Closed, Shock Direction: C1 20 g
Closed, Shock Direction: C2 20 g
Open, Shock Direction: B1 5 g
Open, Shock Direction: C1 9 g
Open, Shock Direction: C2 14 g
Shock Direction: A 20 g
Shock Direction: B2 15 g
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
CB Certificate: CB_CN13475-M1
CCC Certificate: CCC_2007010309251577
CQC Certificate: CQC2007010309251577
Declaration of Conformity - CCC: 2020980304001224
Declaration of Conformity - CE: 1SBD250014U1000
Declaration of Conformity - UKCA: 1SBD250049U1000
Environmental Information: 1SBD250156E1000
GOST Certificate: GOST_POCCCNME77B07822.pdf
Instructions and Manuals: 1SBC101020M9701
RoHS Information: 1SBD251005E1002
UL Certificate: UL_20120917-E312527-1-1
UL Listing Card: UL_E312527

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 72 mm
Package Level 1 Depth / Length: 115 mm
Package Level 1 Height: 48 mm
Package Level 1 Gross Weight: 0.26 kg
Package Level 1 EAN: 3471523067264
Package Level 2 Units: 32 piece
Package Level 2 Width: 250 mm
Package Level 2 Depth / Length: 195 mm
Package Level 2 Height: 315 mm
Package Level 2 Gross Weight: 8.32 kg
Package Level 3 Units: 768 piece

Classifications
Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4755 >> Contactors