Article: AS12-30-01-25

We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | AS12-30-01-25 |
Product ID: | 1SBL111001R2501 |
EAN: | 3471523035256 |
Catalog Description: | AS12-30-01-25 220V50/60HZ Contactor |
Long Description: | AS12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The AS... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available. |
| |
Minimum Order Quantity: | 40 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Instructions and Manuals: | 1SBC101020M9701 |
| |
Product Net Width: | 45 mm |
Product Net Depth / Length: | 72.5 mm |
Product Net Height: | 68 mm |
Product Net Weight: | 0.22 kg |
| |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 0 |
Number of Auxiliary Contacts NC: | 1 |
Standards: | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
Rated Operational Voltage: | Auxiliary Circuit 690 V |
Main Circuit 690 V | |
Rated Frequency (f): | Auxiliary Circuit 50 / 60 Hz |
Main Circuit 50 / 60 Hz | |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 25 A |
acc. to IEC 60947-5-1, q = 40 °C 10 A | |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 24 A |
(690 V) 60 °C 20 A | |
(690 V) 70 °C 16 A | |
Rated Operational Current AC-3 (Ie): | (220 / 230 / 240 V) 60 °C 12 A |
(380 / 400 V) 60 °C 12 A | |
(415 V) 60 °C 12 A | |
(440 V) 60 °C 11 A | |
(500 V) 60 °C 11 A | |
(690 V) 60 °C 7 A | |
Rated Operational Power AC-3 (Pe): | (220 / 230 / 240 V) 3 kW |
(400 V) 5.5 kW | |
(415 V) 5.5 kW | |
(440 V) 5.5 kW | |
(500 V) 5.5 kW | |
(690 V) 5.5 kW | |
Rated Operational Current AC-15 (Ie): | (220 / 240 V) 4 A |
(24 / 127 V) 6 A | |
(400 / 440 V) 3 A | |
(500 V) 2 A | |
(690 V) 2 A | |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 124 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 24 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 75 A | |
for 0.1 s 140 A | |
for 1 s 100 A | |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A | |
Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
(AC-15) 1200 cycles per hour | |
(AC-2 / AC-4) 300 cycles per hour | |
(AC-3) 1200 cycles per hour | |
(DC-13) 900 cycles per hour | |
Rated Operational Current DC-13 (Ie): | (110 V) 0.55 A / 60 W |
(220 V) 0.27 A / 60 W | |
(125 V) 0.55 A / 69 W | |
(24 V) 6 A / 144 W | |
(250 V) 0.27 A / 68 W | |
(48 V) 2.8 A / 134 W | |
(72 V) 1 A / 72 W | |
Rated Insulation Voltage (Ui): | acc. to UL/CSA 600 V |
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | |
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V | |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 220 V |
60 Hz 220 V | |
Operate Time: | Between Coil De-energization and NC Contact Closing 7 ... 22 ms |
Between Coil De-energization and NO Contact Opening 5 ... 19 ms | |
Between Coil Energization and NC Contact Opening 6 ... 18 ms | |
Between Coil Energization and NO Contact Closing 9 ... 24 ms | |
Connecting Capacity Main Circuit: | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | |
Rigid 1/2x 0.75 ... 4 mm² | |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Rigid 1/2x 0.75 ... 2.5 mm² | |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Rigid 1/2x 0.75 ... 2.5 mm² | |
Wire Stripping Length: | Auxiliary Circuit 9 mm |
Control Circuit 9 mm | |
Main Circuit 9 mm | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 | |
Terminal Type: | Screw Terminals |
Technical UL/CSA | |
General Use Rating UL/CSA: | (600 V AC) 20 A |
Horsepower Rating UL/CSA: | (120 V AC) Single Phase 1/2 Hp |
(240 V AC) Single Phase 1.5 Hp | |
(200 ... 208 V AC) Three Phase 2 Hp | |
(220 ... 240 V AC) Three Phase 3 Hp | |
(440 ... 480 V AC) Three Phase 7.5 Hp | |
(550 ... 600 V AC) Three Phase 10 Hp | |
Tightening Torque UL/CSA: | Auxiliary Circuit 9 in·lb |
Control Circuit 9 in·lb | |
Main Circuit 9 in·lb | |
| |
Ambient Air Temperature: | Close to Contactor for Storage -60 ... +80 °C |
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C | |
Close to Contactor without Thermal O/L Relay -40 ... +70 °C | |
Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5 ... 300 Hz 3 g Closed position / 2 g Open position |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: B1 10 g |
Closed, Shock Direction: C1 20 g | |
Closed, Shock Direction: C2 20 g | |
Open, Shock Direction: B1 5 g | |
Open, Shock Direction: C1 9 g | |
Open, Shock Direction: C2 14 g | |
Shock Direction: A 20 g | |
Shock Direction: B2 15 g | |
| |
CB Certificate: | CB_CN13475-M1 |
CCC Certificate: | CCC_2007010309251577 |
CQC Certificate: | CQC2007010309251577 |
Declaration of Conformity - CCC: | 2020980304001224 |
Declaration of Conformity - CE: | 1SBD250014U1000 |
Declaration of Conformity - UKCA: | 1SBD250049U1000 |
Environmental Information: | 1SBD250154E1000 |
GOST Certificate: | GOST_POCCCNME77B07822.pdf |
Instructions and Manuals: | 1SBC101020M9701 |
RoHS Information: | 1SBD251000E1001 |
UL Certificate: | UL_20120917-E312527-1-1 |
UL Listing Card: | UL_E312527 |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 78 mm |
Package Level 1 Depth / Length: | 80 mm |
Package Level 1 Height: | 48 mm |
Package Level 1 Gross Weight: | 0.22 kg |
Package Level 1 EAN: | 3471523035256 |
Package Level 2 Units: | 40 piece |
Package Level 2 Width: | 250 mm |
Package Level 2 Depth / Length: | 195 mm |
Package Level 2 Height: | 315 mm |
Package Level 2 Gross Weight: | 8.8 kg |
Package Level 3 Units: | 960 piece |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
UNSPSC: | 39121529 |
IDEA Granular Category Code (IGCC): | 4755 >> Contactors |