Technical
Number of Main Contacts NO: 4
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 0
Standards: Devices complying with international standards IEC 947-1 / 947-4-1 and European standards EN 60 947-1 / 947-4-1, Electromagnetic compatibility (EMC) acording to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1
Rated Operational Voltage: Main Circuit 690 V
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 22
(690 V) 55 °C 20
(690 V) 70 °C 17
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 25 A
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 90 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 40 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 50 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 200 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 120 A
Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 8 kV
Mechanical Durability: 10 million
Maximum Mechanical Switching Frequency: 6000 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc): DC Operation 48 V
Coil Consumption: Average Holding Value, from Warm State 7 W
Average Pull-in Value, from Cold State 7 W
Operate Time: Between Coil De-energization and NO Contact Opening 15 ... 30 ms
Between Coil Energization and NO Contact Closing 50 ... 75 ms
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied): 2 x M 4
Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting Terminals (delivered in open position) Main Poles: M 3.5 (+,-) pozidriv 2 screws with cable clamp

Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C
Close to Contactor without Thermal O/L Relay (Uc) -55 ... +70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible: 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 m/s²

Certificates and Declarations (Document Number)
BV Certificate: BV_2634I04814E0
CSA Certificate: CSA_LR567458
Declaration of Conformity - CE: 1SBD250813C2000
DNV Certificate: DNV_E4795
Environmental Information: 1SBD250040E1000
GL Certificate: GL_9703681HH
Instructions and Manuals: FPTC407733P0001
LR Certificate: LRS_9830017
UL Certificate: UL_071301E39231

Container Information
Package Level 1 Width: 44 mm
Package Level 1 Height: 81 mm
Package Level 1 Gross Weight: 0.54 kg

Classifications
UNSPSC: 39121529