Article: BC6-30-01-05

Article: BC6-30-01-05

BC6-30-01-05 Mini Contactor 220-240VDC
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration






























































General Information
Extended Product Type: BC6-30-01-05
Product ID: GJL1213001R0015
EAN: 4013614052866
Catalog Description: BC6-30-01-05 Mini Contactor 220-240VDC
Long Description: The BC6-30-01 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 4 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85365080
Popular Downloads
Data Sheet, Technical Information: 1SBC100214C0202
Instructions and Manuals: 2CDC102047M6801
Dimension Diagram: GJL1200436F0001

Dimensions
Product Net Width: 52.5 mm
Product Net Height: 57.5 mm
Product Net Depth / Length: 46.5 mm
Product Net Weight: 0.175 kg

Technical
Number of Poles: 3
Mini Contactor Type: Mini Contactor
Rated Operational Voltage: Auxiliary Circuit 690 V AC
Auxiliary Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 220 V DC
Rated Frequency (f): Control Circuit DC
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
Rated Impulse Withstand Voltage (Uimp): Auxiliary Circuit 6 kV
Main Circuit 6 kV
Rated Insulation Voltage (Ui): 690 V
acc. to UL/CSA 600 V
Number of Main Contacts NC: 0
Number of Main Contacts NO: 3
Rated Operational Current AC-1 (Ie): (220 / 240 V) 40 °C 20 A
(220 / 240 V) 55 °C 16 A
(380 / 440 V) 40 °C 20 A
(380 / 440 V) 55 °C 16 A
(690 V) 40 °C 6 A
(690 V) 55 °C 6 A
Rated Operational Power AC-3 (Pe): (230 V) Three Phase 2.2 kW
(400 V) Three Phase 4 kW
(500 V) Three Phase 4 kW
(690 V) Three Phase, NO 3 kW
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
Number of Auxiliary Contacts NC: 1
Number of Auxiliary Contacts NO: 0
Rated Operational Current AC-15 (Ie): (24 V) 4 A
(120 V) 4 A
(500 V) 2 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie): (24 V) 2.5 A
(110 V) 0.7 A
(220 / 240 V) 0.4 A
Conventional Free-air Thermal Current (Ith): Main Circuit 20 A
Rated Control Circuit Voltage (Uc): 220 ... 240 V DC
Coil Operating Limits: (acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Degree of Protection: Auxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Main Circuit Terminals IP20
Mechanical Durability: 10000000 cycle
Minimum Switching Capacity: Auxiliary Circuit 17 V
Auxiliary Circuit 5 mA
Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour
(AC-15) 600 cycles per hour
(AC-3) 600 cycles per hour
(DC-1) 600 cycles per hour
(DC-13) 600 cycles per hour
(DC-3) 600 cycles per hour
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Wire Stripping Length: Auxiliary Circuit 9 mm
Main Circuit 9 mm
Tightening Torque: Auxiliary Circuit 0.8 ... 1.1 N·m
Control Circuit 0.8 ... 1.1 N·m
Main Circuit 0.8 ... 1.1 N·m
Mounting on DIN Rail: TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Power Loss: at Rated Operating Conditions per Pole 2 W
Standards: IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Auxiliary Circuit 600 V AC/DC
Main Circuit 600 V AC
Full Load Amps Motor Use: (115 V AC) Single Phase 5.8 A
(200 V AC) Three Phase 4.8 A
(220 ... 240 V AC) Three Phase 6.8 A
(230 V AC) Single Phase 4.9 A
(440 ... 480 V AC) Three Phase 4.8 A
(550 ... 600 V AC) Three Phase 1.7 A
Horsepower Rating UL/CSA: (115 V AC) Single Phase 0.25 Hp
(200 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 2 Hp
(230 V AC) Single Phase 0.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 1 Hp
General Use Rating UL/CSA: (300 V AC) 12 A
Connecting Capacity Main Circuit UL/CSA: Stranded 1/2x 22-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA: Stranded 1/2x 22-10 AWG
Tightening Torque UL/CSA: Auxiliary Circuit 7 in·lb
Control Circuit 7 in·lb
Main Circuit 7 in·lb

Environmental
Ambient Air Temperature: Operation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 15g
Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 5 ... 150 Hz
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
BV Certificate: 1SAA920000-0204
CB Certificate: 1SAA938000-2002
CQC Certificate: CQC2003010304064033
cULus Certificate: cUL_E191658
Declaration of Conformity - CCC: 2020980304001854
Declaration of Conformity - CE: 1SAD938517-0001
Declaration of Conformity - UKCA: 1SAD938500-1001
DNV GL Certificate: 1SAA938000-0306
EAC Certificate: 1SAA920000-2702
Environmental Information: 1SAC200067H0009
Instructions and Manuals: 2CDC102047M6801
KC Certificate: 1SAA938000-1501
LR Certificate: 1SAA938000-0504
RMRS Certificate: 1SAA938000-0704
RoHS Information: 1SAD938517-0001

Container Information
Package Level 1 Units: 10 piece
Package Level 1 Width: 115 mm
Package Level 1 Height: 54 mm
Package Level 1 Depth / Length: 280 mm
Package Level 1 Gross Weight: 1.82 kg
Package Level 1 EAN: 4013614414510

Classifications
Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529
E-Number (Finland): 3709117
Accessories