General Information | |
| Extended Product Type: | BC16-30-01 12V DC |
| Product ID: | FPL1813001R0017 |
| EAN: | 3471521180071 |
| Catalog Description: | CONTACTOR |
| Long Description: | CONTACTOR |
| |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information: | 1SBC100122C0201-Ch02 |
| Instructions and Manuals: | FPTC407733P0001 |
| |
| Product Net Weight: | 0.54 kg |
| |
| Number of Main Contacts NO: | 3 |
| Number of Main Contacts NC: | 0 |
| Number of Auxiliary Contacts NO: | 0 |
| Number of Auxiliary Contacts NC: | 1 |
| Standards: | Devices complying with international standards IEC 947-1 / 947-4-1 and European standards EN 60 947-1 / 947-4-1, Electromagnetic compatibility (EMC) acording to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1 |
| Rated Operational Voltage: | Main Circuit 690 V |
| Rated Frequency (f): | Supply Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 28 A |
| acc. to IEC 60947-5-1, q = 40 °C 10 A | |
| q = 40 °C 10 A | |
| Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 28 |
| (690 V) 55 °C 25 | |
| (690 V) 70 °C 23 | |
| Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
| Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
| (690 V) 2 A | |
| (24 / 127 V) 6 A | |
| (220 / 240 V) 4 A | |
| (380 / 400 V) 3 A | |
| Short-Circuit Protective Devices: | Auxiliary Circuit - gG Type Fuses 10 A |
| gG Type Fuses 32 / 35 A | |
| Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 130 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A | |
| for 0.1 s 100 A | |
| for 1 s 50 A | |
| Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 200 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 120 A | |
| Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
| (AC-2 / AC-4) 300 cycles per hour | |
| (AC-3) 1200 cycles per hour | |
| Rated Operational Current DC-13 (Ie): | (24 V) 6 / 144 A |
| (48 V) 2.8 / 134 A | |
| (72 V) 2 / 144 A | |
| (125 V) 1.1 / 138 A | |
| (250 V) 0.55 / 138 A | |
| Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp): | 8 kV |
| Mechanical Durability: | 10 million |
| Maximum Mechanical Switching Frequency: | 6000 cycles per hour |
| Coil Operating Limits: | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (Uc): | DC Operation 12 V |
| Coil Consumption: | Average Holding Value, from Warm State 7 W |
| Average Pull-in Value, from Cold State 7 W | |
| Operate Time: | Between Coil De-energization and NC Contact Closing 17 ... 32 ms |
| Between Coil De-energization and NO Contact Opening 15 ... 30 ms | |
| Between Coil Energization and NC Contact Opening 45 ... 70 ms | |
| Between Coil Energization and NO Contact Closing 50 ... 75 ms | |
| Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied): | 2 x M 4 |
| Connecting Capacity Main Circuit: | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Connecting Capacity Auxiliary Circuit: | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP10 |
| Connecting Terminals (delivered in open position) Main Poles: | M 3.5 (+,-) pozidriv 2 screws with cable clamp |
| |
| Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C | |
| Close to Contactor without Thermal O/L Relay (Uc) -55 ... +70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Climatic Withstand: | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
| Maximum Operating Altitude Permissible: | 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27: | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 m/s² |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 m/s² | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 m/s² | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 m/s² | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 m/s² | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 m/s² | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 m/s² | |
| |
| BV Certificate: | BV_2634I04814E0 |
| CSA Certificate: | CSA_LR567458 |
| Declaration of Conformity - CE: | 1SBD250812C2000 |
| DEMKO Certificate: | DEMKO_74447BTH |
| DNV Certificate: | DNV_E4795 |
| Environmental Information: | 1SBD250041E1000 |
| GL Certificate: | GL_9703681HH |
| Instructions and Manuals: | FPTC407733P0001 |
| LR Certificate: | LRS_9830017 |
| UL Certificate: | UL_071301E39231 |
| |
| Package Level 1 Units: | 1 piece |
| Package Level 1 Width: | 44 mm |
| Package Level 1 Height: | 81 mm |
| Package Level 1 Gross Weight: | 0.54 kg |
| |
| UNSPSC: | 39121529 |