Article: AX06-30-01-80

Article: AX06-30-01-80

AX06-30-01-80 220-230V50Hz 230-240V60Hz Contactor
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration

















































General Information
Extended Product Type: AX06-30-01-80
Product ID: 1SBL891074R8001
EAN: 3471522410801
Catalog Description: AX06-30-01-80 220-230V50Hz 230-240V60Hz Contactor
Long Description: AX06 contactor relays are used for switching auxiliary and control circuits.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Instructions and Manuals: 9AKK107492A7057

Dimensions
Product Net Width: 44 mm
Product Net Depth / Length: 74 mm
Product Net Height: 74 mm
Product Net Weight: 0.326 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 1
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 22 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 20 A
(690 V) 70 °C 16 A
(220 / 240 V) 55 °C 20 A
Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 7 A
(380 / 400 V) 55 °C 7 A
(415 V) 55 °C 7 A
(440 V) 55 °C 7 A
(500 V) 55 °C 7 A
(690 V) 55 °C 5 A
Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 1.5 kW
(380 / 400 V) 3 kW
(415 V) 3 kW
(440 V) 3 kW
(500 V) 3.5 kW
(690 V) 4 kW
Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 2 A
(690 V) 2 A
(380 / 440 V) 3 A
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 60 A
for 1 s -empty- A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie): (110 V) 1.1 A / 121 W
(220 V) 0.55 A / 121 W
(400 V) 2.8 A / 134 W
(500 V) 2 A / 144 W
(125 V) 1.1 A / 138 W
(24 V) 6 A / 144 W
(250 V) 0.55 A / 138 W
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Operate Time: Between Coil De-energization and NC Contact Closing 9 ... 16 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 21 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal Type: Screw Terminals
Technical UL/CSA
General Use Rating UL/CSA: (600 V AC) 20 A
Horsepower Rating UL/CSA: (120 V AC) Single Phase 1/3 Hp
(240 V AC) Single Phase 3/4 Hp
(200 ... 208 V AC) Three Phase 1.5 Hp
(220 ... 240 V AC) Three Phase 2 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 5 Hp
Tightening Torque UL/CSA: Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 9 in·lb

Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible: 3000 m
RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment

Certificates and Declarations (Document Number)
CB Certificate: 9AKK107492A7072
CCC Certificate: 9AKK107492A7089
CCS Certificate: 9AKK107492A7096
CQC Certificate: CQC2013010304646608
Declaration of Conformity - CCC: 2020980304001066
Declaration of Conformity - CE: 1SBD250011U1000
Instructions and Manuals: 9AKK107492A7057
RoHS Information: 1SBD251301E1000

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 48 mm
Package Level 1 Depth / Length: 78 mm
Package Level 1 Height: 79 mm
Package Level 1 Gross Weight: 0.34 kg
Package Level 1 EAN: 3471522410801
Package Level 2 Units: 30 piece
Package Level 2 Width: 240 mm
Package Level 2 Depth / Length: 295 mm
Package Level 2 Height: 145 mm
Package Level 2 Gross Weight: 10.2 kg

Classifications
Object Classification Code: Q
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4755 >> Contactors