General Information | |
| Extended Product Type: | AX50-30-00-83 |
| Product ID: | 1SBL351074R8300 |
| EAN: | 3471522403834 |
| Catalog Description: | AX50-30-00-83 48V 50/60Hz Contactor |
| Long Description: | AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories. |
| |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85364900 |
| Popular Downloads | |
| Instructions and Manuals: | 9AKK107492A7059 |
| |
| Product Net Width: | 70 mm |
| Product Net Depth / Length: | 110 mm |
| Product Net Height: | 108 mm |
| Product Net Weight: | 1.01 kg |
| |
| Number of Main Contacts NO: | 3 |
| Number of Main Contacts NC: | 0 |
| Number of Auxiliary Contacts NO: | 0 |
| Number of Auxiliary Contacts NC: | 0 |
| Rated Operational Voltage: | Auxiliary Circuit 690 V |
| Main Circuit 690 V | |
| Rated Frequency (f): | Auxiliary Circuit 50 / 60 Hz |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 100 A |
| Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 100 A |
| (690 V) 70 °C 70 A | |
| (220 / 240 V) 55 °C 85 A | |
| Rated Operational Current AC-3 (Ie): | (220 / 230 / 240 V) 55 °C 53 A |
| (380 / 400 V) 55 °C 50 A | |
| (415 V) 55 °C 50 A | |
| (440 V) 55 °C 45 A | |
| (500 V) 55 °C 45 A | |
| (690 V) 55 °C 35 A | |
| Rated Operational Power AC-3 (Pe): | (220 / 230 / 240 V) 15 kW |
| (380 / 400 V) 22 kW | |
| (415 V) 25 kW | |
| (440 V) 25 kW | |
| (500 V) 30 kW | |
| (690 V) 30 kW | |
| Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A | |
| for 1 s -empty- A | |
| Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A | |
| Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
| (AC-3) 600 cycles per hour | |
| Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (Uimp): | 6 kV |
| Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc): | 50 Hz 48 V |
| 60 Hz 48 V | |
| Operate Time: | Between Coil De-energization and NC Contact Closing 7 ... 14 ms |
| Between Coil De-energization and NO Contact Opening 4 ... 11 ms | |
| Between Coil Energization and NC Contact Opening 7 ... 22 ms | |
| Between Coil Energization and NO Contact Closing 8 ... 27 ms | |
| Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Terminal Type: | Screw Terminals |
| Technical UL/CSA | |
| General Use Rating UL/CSA: | (600 V AC) 80 A |
| Horsepower Rating UL/CSA: | (120 V AC) Single Phase 3 Hp |
| (240 V AC) Single Phase 10 Hp | |
| (200 ... 208 V AC) Three Phase 15 Hp | |
| (220 ... 240 V AC) Three Phase 20 Hp | |
| (440 ... 480 V AC) Three Phase 40 Hp | |
| (550 ... 600 V AC) Three Phase 50 Hp | |
| Tightening Torque UL/CSA: | Auxiliary Circuit 9 in·lb |
| Control Circuit 9 in·lb | |
| Main Circuit 35 in·lb | |
| |
| Ambient Air Temperature: | Close to Contactor for Storage -60 ... +80 °C |
| Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C | |
| Close to Contactor without Thermal O/L Relay -40 ... +70 °C | |
| Near Contactor for Operation in Free Air -40 ... +70 °C | |
| Climatic Withstand: | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
| Maximum Operating Altitude Permissible: | 3000 m |
| RoHS Status: | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| |
| CB Certificate: | 9AKK107492A7074 |
| CCC Certificate: | 9AKK107492A7091 |
| CCS Certificate: | 9AKK107492A7096 |
| CQC Certificate: | CQC2013010304646607 |
| Declaration of Conformity - CCC: | 2020980304001064 |
| Declaration of Conformity - CE: | 1SBD250011U1000 |
| Instructions and Manuals: | 9AKK107492A7059 |
| RoHS Information: | 1SBD251301E1000 |
| |
| Package Level 1 Units: | 1 piece |
| Package Level 1 Width: | 102 mm |
| Package Level 1 Depth / Length: | 143 mm |
| Package Level 1 Height: | 152 mm |
| Package Level 1 Gross Weight: | 1.12 kg |
| Package Level 1 EAN: | 3471522403834 |
| Package Level 2 Units: | 10 piece |
| Package Level 2 Width: | 240 mm |
| Package Level 2 Depth / Length: | 295 mm |
| Package Level 2 Height: | 145 mm |
| Package Level 2 Gross Weight: | 11.2 kg |
| |
| Object Classification Code: | Q |
| ETIM 6: | EC000066 - Power contactor, AC switching |
| ETIM 7: | EC000066 - Power contactor, AC switching |
| UNSPSC: | 39121529 |
| IDEA Granular Category Code (IGCC): | 4755 >> Contactors |