Article: AX40-30-10-88

Article: AX40-30-10-88
AX40-30-10-88 230-240V50Hz/240V-260V60Hz Contactor
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
| Extended Product Type: | AX40-30-10-88 |
| Product ID: | 1SBL321074R8810 |
| EAN: | 3471522401885 |
| Catalog Description: | AX40-30-10-88 230-240V50Hz/240V-260V60Hz Contactor |
| Long Description: | AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories. |
| |
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85364900 |
| Popular Downloads | |
| Instructions and Manuals: | 9AKK107492A7057 |
| |
| Product Net Width: | 54 mm |
| Product Net Depth / Length: | 90 mm |
| Product Net Height: | 108.3 mm |
| Product Net Weight: | 0.667 kg |
| |
| Number of Main Contacts NO: | 3 |
| Number of Main Contacts NC: | 0 |
| Number of Auxiliary Contacts NO: | 1 |
| Number of Auxiliary Contacts NC: | 0 |
| Rated Operational Voltage: | Auxiliary Circuit 690 V |
| Main Circuit 690 V | |
| Rated Frequency (f): | Auxiliary Circuit 50 / 60 Hz |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 65 A |
| acc. to IEC 60947-5-1, q = 40 °C 16 A | |
| Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 60 A |
| (690 V) 70 °C 42 A | |
| (220 / 240 V) 55 °C 60 A | |
| Rated Operational Current AC-3 (Ie): | (220 / 230 / 240 V) 55 °C 40 A |
| (380 / 400 V) 55 °C 40 A | |
| (415 V) 55 °C 40 A | |
| (440 V) 55 °C 37 A | |
| (500 V) 55 °C 33 A | |
| (690 V) 55 °C 25 A | |
| Rated Operational Power AC-3 (Pe): | (220 / 230 / 240 V) 11 kW |
| (380 / 400 V) 18.5 kW | |
| (415 V) 18.5 kW | |
| (440 V) 22 kW | |
| (500 V) 22 kW | |
| (690 V) 22 kW | |
| Rated Operational Current AC-15 (Ie): | (220 / 240 V) 4 A |
| (24 / 127 V) 6 A | |
| (400 / 440 V) 2 A | |
| (500 V) 2 A | |
| (690 V) 2 A | |
| (380 / 440 V) 3 A | |
| Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | |
| for 0.1 s 140 A | |
| for 1 s 100 A | |
| Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A | |
| Maximum Electrical Switching Frequency: | (AC-1) 600 cycles per hour |
| (AC-15) 1200 cycles per hour | |
| (AC-3) 1200 cycles per hour | |
| (DC-13) 900 cycles per hour | |
| Rated Operational Current DC-13 (Ie): | (110 V) 1.1 A / 121 W |
| (220 V) 0.55 A / 121 W | |
| (400 V) 2.8 A / 134 W | |
| (500 V) 2 A / 144 W | |
| (125 V) 1.1 A / 138 W | |
| (24 V) 6 A / 144 W | |
| (250 V) 0.55 A / 138 W | |
| Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (Uimp): | 6 kV |
| Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc): | 50 Hz 230 ... 240 V |
| 60 Hz 240 ... 260 V | |
| Operate Time: | Between Coil De-energization and NC Contact Closing 7 ... 14 ms |
| Between Coil De-energization and NO Contact Opening 4 ... 11 ms | |
| Between Coil Energization and NC Contact Opening 6 ... 18 ms | |
| Between Coil Energization and NO Contact Closing 8 ... 21 ms | |
| Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 | |
| Terminal Type: | Screw Terminals |
| Technical UL/CSA | |
| General Use Rating UL/CSA: | (600 V AC) 60 A |
| Horsepower Rating UL/CSA: | (120 V AC) Single Phase 3 Hp |
| (240 V AC) Single Phase 7.5 Hp | |
| (200 ... 208 V AC) Three Phase 10 Hp | |
| (220 ... 240 V AC) Three Phase 15 Hp | |
| (440 ... 480 V AC) Three Phase 30 Hp | |
| (550 ... 600 V AC) Three Phase 40 Hp | |
| Tightening Torque UL/CSA: | Auxiliary Circuit 9 in·lb |
| Control Circuit 9 in·lb | |
| Main Circuit 20 in·lb | |
| |
| Ambient Air Temperature: | Close to Contactor for Storage -60 ... +80 °C |
| Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C | |
| Close to Contactor without Thermal O/L Relay -40 ... +70 °C | |
| Near Contactor for Operation in Free Air -40 ... +70 °C | |
| Climatic Withstand: | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
| Maximum Operating Altitude Permissible: | 3000 m |
| RoHS Status: | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| |
| CB Certificate: | 9AKK107492A7073 |
| CCC Certificate: | 9AKK107492A7090 |
| CCS Certificate: | 9AKK107492A7096 |
| CQC Certificate: | CQC2013010304647116 |
| Declaration of Conformity - CCC: | 2020980304001065 |
| Declaration of Conformity - CE: | 1SBD250011U1000 |
| Instructions and Manuals: | 9AKK107492A7057 |
| RoHS Information: | 1SBD251301E1000 |
| |
| Package Level 1 Units: | 1 piece |
| Package Level 1 Width: | 65 mm |
| Package Level 1 Depth / Length: | 101 mm |
| Package Level 1 Height: | 115 mm |
| Package Level 1 Gross Weight: | 0.71 kg |
| Package Level 1 EAN: | 3471522401885 |
| Package Level 2 Units: | 12 piece |
| Package Level 2 Width: | 240 mm |
| Package Level 2 Depth / Length: | 295 mm |
| Package Level 2 Height: | 145 mm |
| Package Level 2 Gross Weight: | 8.52 kg |
| |
| Object Classification Code: | Q |
| ETIM 6: | EC000066 - Power contactor, AC switching |
| ETIM 7: | EC000066 - Power contactor, AC switching |
| UNSPSC: | 39121529 |
| IDEA Granular Category Code (IGCC): | 4755 >> Contactors |