AX40-30-10-26 110-127V60HZ/105V50HZ Contactor
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration

















































General Information
Extended Product Type: AX40-30-10-26
Product ID: 1SBL321074R2610
EAN: 3471522401267
Catalog Description: AX40-30-10-26 110-127V60HZ/105V50HZ Contactor
Long Description: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Instructions and Manuals: 9AKK107492A7057

Dimensions
Product Net Width: 54 mm
Product Net Depth / Length: 90 mm
Product Net Height: 108.3 mm
Product Net Weight: 0.667 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 0
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 65 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 60 A
(690 V) 70 °C 42 A
(220 / 240 V) 55 °C 60 A
Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 40 A
(380 / 400 V) 55 °C 40 A
(415 V) 55 °C 40 A
(440 V) 55 °C 37 A
(500 V) 55 °C 33 A
(690 V) 55 °C 25 A
Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 11 kW
(380 / 400 V) 18.5 kW
(415 V) 18.5 kW
(440 V) 22 kW
(500 V) 22 kW
(690 V) 22 kW
Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 2 A
(690 V) 2 A
(380 / 440 V) 3 A
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
for 1 s -empty- A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie): (110 V) 1.1 A / 121 W
(220 V) 0.55 A / 121 W
(400 V) 2.8 A / 134 W
(500 V) 2 A / 144 W
(125 V) 1.1 A / 138 W
(24 V) 6 A / 144 W
(250 V) 0.55 A / 138 W
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 105 V
60 Hz 110 ... 127 V
Operate Time: Between Coil De-energization and NC Contact Closing 7 ... 14 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 6 ... 18 ms
Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal Type: Screw Terminals
Technical UL/CSA
General Use Rating UL/CSA: (600 V AC) 60 A
Horsepower Rating UL/CSA: (120 V AC) Single Phase 3 Hp
(240 V AC) Single Phase 7.5 Hp
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 40 Hp
Tightening Torque UL/CSA: Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 20 in·lb

Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible: 3000 m
RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment

Certificates and Declarations (Document Number)
CB Certificate: 9AKK107492A7073
CCC Certificate: 9AKK107492A7090
CCS Certificate: 9AKK107492A7096
CQC Certificate: CQC2013010304647116
Declaration of Conformity - CCC: 2020980304001065
Declaration of Conformity - CE: 1SBD250011U1000
Instructions and Manuals: 9AKK107492A7057
RoHS Information: 1SBD251301E1000

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 65 mm
Package Level 1 Depth / Length: 101 mm
Package Level 1 Height: 115 mm
Package Level 1 Gross Weight: 0.71 kg
Package Level 1 EAN: 3471522401267
Package Level 2 Units: 12 piece
Package Level 2 Width: 240 mm
Package Level 2 Depth / Length: 295 mm
Package Level 2 Height: 145 mm
Package Level 2 Gross Weight: 8.52 kg

Classifications
Object Classification Code: Q
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4755 >> Contactors