Article: N80E 220-230V 50Hz / 230-240V 60Hz

Article: N80E 220-230V 50Hz / 230-240V 60Hz
N80E 220-230V 50Hz / 230-240V 60Hz Contactor Relay
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | N80E 220-230V 50Hz / 230-240V 60Hz |
Product ID: | 1SBH141001R8080 |
EAN: | 3471522017802 |
Catalog Description: | N80E 220-230V 50Hz / 230-240V 60Hz Contactor Relay |
Long Description: | N... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 8-pole contactor relays (mechanically linked contact elements available) The width of 8-pole devices is identical to that of 4-pole devices only the depth is increased - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.only the depth is increased- Control circuit: AC operated with laminated magnet circuit- Accessories: a wide range of accessories is available. |
only the depth is increased- Control circuit: AC operated with laminated magnet circuit- Accessories: a wide range of accessories is available. | |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Replacement Product ID (NEW): | 1SBH131001R8080 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100122C0202_Ch03 |
Instructions and Manuals: | FPTC407721P0001 |
| |
Product Net Width: | 44 mm |
Product Net Depth / Length: | 107 mm |
Product Net Height: | 74 mm |
Product Net Weight: | 0.4 kg |
| |
Number of Auxiliary Contacts NO: | 8 |
Number of Auxiliary Contacts NC: | 0 |
Standards: | Devices complying with international standards IEC 947-5-1 / 947-4-1 and European standards EN 60 947-5-1 / 60 947-4-1. Electromagnetic compatibility (EMC) according to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1 |
Rated Operational Voltage: | Main Circuit 690 V |
Rated Frequency (f): | Supply Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-5-1, q = 40 °C 16 A |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(380 / 400 V) 3 A | |
Short-Circuit Protective Devices: | gG Type Fuses 10 A |
Rated Operational Current DC-13 (Ie): | (24 V) 6 / 144 A |
(48 V) 2.8 / 134 A | |
(72 V) 1 / 72 A | |
(125 V) 0.55 / 69 A | |
(250 V) 0.3 / 75 A | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Mechanical Durability: | > 20 million |
Maximum Mechanical Switching Frequency: | 6000 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 220 ... 230 V |
60 Hz 230 ... 240 V | |
Coil Consumption: | Average Holding Value 50 / 60 Hz 8 V·A |
Average Pull-in Value 50 Hz 74 V·A | |
Average Pull-in Value 60 Hz 70 V·A | |
Holding at Max. Rated Control Circuit Voltage 50 Hz 8 2 V·A | |
Holding at Max. Rated Control Circuit Voltage 60 Hz 8 2 V·A | |
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 70 V·A | |
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 80 V·A | |
Operate Time: | Between Coil De-energization and NO Contact Opening 4 ... 11 ms |
Between Coil Energization and NO Contact Closing 10 ... 26 ms | |
Connecting Capacity Auxiliary Circuit: | Flexible with Cable End 0.75 ... 2.5 mm² |
Rigid Cable 1 ... 4 mm² | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
Terminal Type: | Screw Terminals |
| |
Ambient Air Temperature: | Close to Contactor for Storage -60 ... +80 °C |
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C | |
Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C | |
Climatic Withstand: | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: B1 10 K40 |
Open, Shock Direction: B1 5 K40 | |
Shock Direction: A 20 K40 | |
Shock Direction: B2 15 K40 | |
Shock Direction: C1 20 K40 | |
Shock Direction: C2 20 K40 | |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
BV Certificate: | BV_2634H09651D0 |
CB Certificate: | CB_FR_602227B |
CCC Certificate: | CCC_2018010304059155 |
CQC Certificate: | CQC2018010304059155 |
CSA Certificate: | CSA_1041746 |
Declaration of Conformity - CCC: | 2020980303000257 |
Declaration of Conformity - CE: | 1SBD250808U1000 |
DNV Certificate: | DNV-GL_TAE00000TY |
DNV GL Certificate: | DNV-GL_TAE00000TY |
Environmental Information: | 1SBD250049E1002 |
GOST Certificate: | GOST_POCCFRME01B03022 |
Instructions and Manuals: | FPTC407721P0001 |
LR Certificate: | LRS_9830010E2 |
RINA Certificate: | RINA_ELE128713XG002 |
RMRS Certificate: | RMRS_0507015250 |
RoHS Information: | 1SBD250808U1000 |
UL Certificate: | UL_110105E48139A |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 78 mm |
Package Level 1 Depth / Length: | 110 mm |
Package Level 1 Height: | 46 mm |
Package Level 1 Gross Weight: | 0.4 kg |
Package Level 1 EAN: | 3471522017802 |
Package Level 2 Units: | box 48 piece |
Package Level 2 Width: | 300 mm |
Package Level 2 Depth / Length: | 245 mm |
Package Level 2 Height: | 308 mm |
Package Level 2 Gross Weight: | 19.2 kg |
Package Level 3 Units: | 576 piece |
| |
Object Classification Code: | K |
ETIM 4: | EC000196 - Contactor relay |
ETIM 5: | EC000196 - Contactor relay |
ETIM 6: | EC000196 - Contactor relay |
ETIM 7: | EC000196 - Contactor relay |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121500 |