Extended Product Type: | KC22E 110V DC |
Product ID: | FPH1413001R0224 |
EAN: | 3471520505141 |
Catalog Description: | CONTACTOR RELAYS |
Long Description: | CONTACTOR RELAYS |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362090 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100122C0201-Ch02 |
Instructions and Manuals: | FPTC407733P0001 |
| |
Product Net Weight: | 0.54 kg |
| |
Number of Main Contacts NO: | 0 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 2 |
Number of Auxiliary Contacts NC: | 2 |
Standards: | Devices complying with international standards IEC 947-5-1 / 947-4-1 and European standards EN 60 947-5-1 / 947-4-1, Electromagnetic compatibility (EMC) acording to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1 |
Rated Operational Voltage: | Main Circuit 690 V |
Rated Frequency (f): | Supply Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-5-1, q = 40 °C 10 A |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(380 / 400 V) 3 A | |
Short-Circuit Protective Devices: | gG Type Fuses 10 A |
Rated Short-time Withstand Current (Icw): | for 0.1 s 100 A |
for 1 s 50 A | |
Rated Operational Current DC-13 (Ie): | (24 V) 6 / 144 A |
(48 V) 2.8 / 134 A | |
(72 V) 1 / 72 A | |
(125 V) 0.55 / 69 A | |
(250 V) 0.3 / 75 A | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Maximum Mechanical Switching Frequency: | 6000 cycles per hour |
Coil Operating Limits: | (acc. to IEC 60947-5-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
Rated Control Circuit Voltage (Uc): | DC Operation 110 V |
Coil Consumption: | Average Holding Value, from Warm State 7 W |
Average Pull-in Value, from Cold State 7 W | |
Operate Time: | Between Coil De-energization and NC Contact Closing 17 ... 32 ms |
Between Coil De-energization and NO Contact Opening 15 ... 30 ms | |
Between Coil Energization and NC Contact Opening 45 ... 70 ms | |
Between Coil Energization and NO Contact Closing 50 ... 75 ms | |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
Mounting by Screws (not supplied): | 2 x M 4 |
Connecting Capacity Auxiliary Circuit: | Flexible with Cable End 0.75 ... 2.5 mm² |
Rigid Cable 1 ... 4 mm² | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP10 |
| |
Ambient Air Temperature: | Close to Contactor for Storage -60 ... +80 °C |
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C | |
Near Contactor for Operation in Free Air (Uc) +55 ... +70 °C | |
Storage -60 ... +80 °C | |
Climatic Withstand: | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Shock acc. to IEC 60068-2-27: | Half-sine Pulse for 11 ms, No Change in Contact Position, Shock Direction: A 20 m/s² |
Half-sine Pulse for 11 ms, No Change in Contact Position, Shock Direction: B1 5 m/s² | |
Half-sine Pulse for 11 ms, No Change in Contact Position, Shock Direction: B2 15 m/s² | |
Half-sine Pulse for 11 ms, No Change in Contact Position, Shock Direction: C1 20 m/s² | |
Half-sine Pulse for 11 ms, No Change in Contact Position, Shock Direction: C2 20 m/s² | |
| |
BV Certificate: | BV_2634H07750B0 |
Declaration of Conformity - CE: | 1SBD250814C2000 |
DNV Certificate: | DNV_E4794 |
Environmental Information: | 1SBD250050E1000 |
Instructions and Manuals: | FPTC407733P0001 |
UL Certificate: | UL_071301E48139 |
UL Listing Card: | UL_E48139 |