Article: NSL44E-88M

Article: NSL44E-88M

NSL44E-88M 220VDC Contactor Relay
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration




































General Information
Extended Product Type: NSL44E-88M
Product ID: 1SBH103001M8844
EAN: 3471523058385
Catalog Description: NSL44E-88M 220VDC Contactor Relay
Long Description: NSL... contactor relays are used for switching auxiliary circuits and control circuits. - Poles: 8-pole contactor relays (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor relay side) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NSL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.

Ordering
Minimum Order Quantity: 20 piece
Customs Tariff Number: 85364900
Popular Downloads
Instructions and Manuals: 1SBC101020M9701

Dimensions
Product Net Width: 45 mm
Product Net Depth / Length: 100.2 mm
Product Net Height: 68 mm
Product Net Weight: 0.32 kg

Technical
Number of Auxiliary Contacts NO: 4
Number of Auxiliary Contacts NC: 4
Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-5-1, q = 40 °C 10 A
Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
Rated Short-time Withstand Current (Icw): for 0.1 s 140 A
for 1 s 100 A
Maximum Electrical Switching Frequency: (AC-15) 1200 cycles per hour
(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie): (110 V) 0.55 A / 60 W
(220 V) 0.27 A / 60 W
(125 V) 0.55 A / 69 W
(24 V) 6 A / 144 W
(250 V) 0.27 A / 68 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): DC Operation 220 V
Operate Time: Between Coil De-energization and NC Contact Closing 15 ... 20 ms
Between Coil De-energization and NO Contact Opening 13 ... 17 ms
Between Coil Energization and NC Contact Opening 31 ... 53 ms
Between Coil Energization and NO Contact Closing 36 ... 59 ms
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping Length: Auxiliary Circuit 9 mm
Control Circuit 9 mm
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal Type: Screw Terminals
Technical UL/CSA
Tightening Torque UL/CSA: Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb

Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
Climatic Withstand: Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible: 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 3 g Closed position / 2 g Open position
Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 20 g
Closed, Shock Direction: B1 15 g
Closed, Shock Direction: C1 19 g
Closed, Shock Direction: C2 14 g
Open, Shock Direction: A 10 g
Open, Shock Direction: B1 5 g
Open, Shock Direction: C1 8 g
Open, Shock Direction: C2 8 g
Shock Direction: B2 10 g
RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment

Certificates and Declarations (Document Number)
CB Certificate: CB_CN_32453
CCC Certificate: CCC_2007010305248106
CQC Certificate: CQC2007010305248106
Declaration of Conformity - CCC: 2020980304001219
Declaration of Conformity - CE: 1SBD250016U1000
Declaration of Conformity - UKCA: 1SBD250051U1000
Environmental Information: 1SBD250160E1000
GOST Certificate: GOST_POCCCNME77B07821.pdf
Instructions and Manuals: 1SBC101020M9701
RoHS Information: 1SBD251003E1000
UL Certificate: UL_220108-E312527A
UL Listing Card: NOA_E312527.pdf

Container Information
Package Level 1 Units: 20 piece
Package Level 1 Width: 293 mm
Package Level 1 Depth / Length: 128 mm
Package Level 1 Height: 247 mm
Package Level 1 Gross Weight: 6.4 kg
Package Level 1 EAN: 3471523058385
Package Level 2 Units: 20 piece
Package Level 2 Width: 293 mm
Package Level 2 Depth / Length: 128 mm
Package Level 2 Height: 247 mm
Package Level 2 Gross Weight: 6.4 kg
Package Level 3 Units: 640 piece

Classifications
Object Classification Code: K
ETIM 4: EC000196 - Contactor relay
ETIM 5: EC000196 - Contactor relay
ETIM 6: EC000196 - Contactor relay
ETIM 7: EC000196 - Contactor relay
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4755 >> Contactors