Article: TAE75-30-00RT 77-143V DC

Article: TAE75-30-00RT 77-143V DC
TAE75-30-00RT 77-143V DC Contactor
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | TAE75-30-00RT 77-143V DC |
Product ID: | 1SBL419060R6200 |
EAN: | 3471522244864 |
Catalog Description: | TAE75-30-00RT 77-143V DC Contactor |
Long Description: | TAE75 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The TAE..RT contactors are the Ring Tongue terminal version of the TAE... range. The TAE... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with standard double-winding DC coils (with add-on factory-mounted lagging contact for insertion of the"holding" winding). TAE... contactors offer a large coil voltage range - Accessories: a wide range of accessories is available. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SNC001003C0202 |
Instructions and Manuals: | FPTC407767P0002 |
| |
Product Net Width: | 82 mm |
Product Net Depth / Length: | 108 mm |
Product Net Height: | 110 mm |
Product Net Weight: | 1.2 kg |
| |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 0 |
Number of Auxiliary Contacts NC: | 0 |
Rated Operational Voltage: | Main Circuit 1000 V |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A |
Rated Operational Current AC-1 (Ie): | (690 V) 40 °C 125 |
(690 V) 55 °C 105 | |
Rated Operational Current AC-3 (Ie): | (415 V) 55 °C 72 A |
(440 V) 55 °C 70 A | |
(500 V) 55 °C 65 A | |
(690 V) 55 °C 46 A | |
(1000 V) 55 °C 28 A | |
(380 / 400 V) 55 °C 75 A | |
(220 / 230 / 240 V) 55 °C 75 | |
Rated Operational Power AC-3 (Pe): | (415 V) 40 kW |
(440 V) 40 kW | |
(500 V) 45 kW | |
(690 V) 40 kW | |
(380 / 400 V) 37 kW | |
(220 / 230 / 240 V) 22 kW | |
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
Short-Circuit Protective Devices: | gG Type Fuses 160 A |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A | |
Maximum Electrical Switching Frequency: | (AC-1) 300 cycles per hour |
(AC-2 / AC-4) 150 cycles per hour | |
(AC-3) 300 cycles per hour | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Mechanical Durability: | 5 million |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc): | DC Operation 77 ... 143 V |
Coil Consumption: | Holding DC (Umin / Umax) 1.7 / 6.5 W |
Pull-in DC (Umin / Umax) 120 / 250 W | |
Operate Time: | Between Coil De-energization and NC Contact Closing 8 ... 18 ms |
Between Coil De-energization and NO Contact Opening 5 ... 15 ms | |
Between Coil Energization and NC Contact Opening 10 ... 27 ms | |
Between Coil Energization and NO Contact Closing 30 ... 30 ms | |
Connecting Capacity Auxiliary Circuit: | Solid 1 ... 4 mm² |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
Terminal Type: | Ring-Tongue Terminals |
Technical UL/CSA | |
General Use Rating UL/CSA: | (600 V AC) 105 A |
| |
Ambient Air Temperature: | Close to Contactor without Thermal O/L Relay -40 ... 55 °C |
Close to Contactor for Storage -60 ... +80 °C | |
Climatic Withstand: | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: B1 10 g |
Open, Shock Direction: B1 5 g | |
Shock Direction: A 20 g | |
Shock Direction: B2 15 g | |
Shock Direction: C1 20 g | |
Shock Direction: C2 20 g | |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CB Certificate: | CB_FR_701506-A1 |
CQC Certificate: | CQC2018010304129269 |
Declaration of Conformity - CCC: | 2020980304001621 |
Declaration of Conformity - CE: | 1SBD250806U1000 |
Environmental Information: | 1SBD250025E1003 |
GOST Certificate: | GOST_POCCFRME77B07175 |
Instructions and Manuals: | FPTC407767P0002 |
RoHS Information: | 1SBD250806U1000 |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 140 mm |
Package Level 1 Depth / Length: | 146 mm |
Package Level 1 Height: | 96 mm |
Package Level 1 Gross Weight: | 1.2 kg |
Package Level 1 EAN: | 3471522244864 |
Package Level 2 Units: | box 20 piece |
Package Level 2 Gross Weight: | 24 kg |
| |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
eClass: | V11.0 : 27371018 |
UNSPSC: | 39121529 |