Article: TNL80E 77-143V DC

Article: TNL80E 77-143V DC
TNL80E 77-143V DC Contactor Relay
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | TNL80E 77-143V DC |
Product ID: | 1SBH143061R6280 |
EAN: | 3471522332622 |
Catalog Description: | TNL80E 77-143V DC Contactor Relay |
Long Description: | TNL... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 8-pole contactor relays (mechanically linked contact elements available) The width of 8-pole devices is identical to that of 4-pole devices only the depth is increased - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available TNL... contactor relays are fitted with low consumption DC coils and offer a large coil voltage range.only the depth is increased- Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected- Accessories: a wide range of accessories is availableTNL... contactor relays are fitted with low consumption DC coils and offer a large coil voltage range. |
only the depth is increased- Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected- Accessories: a wide range of accessories is availableTNL... contactor relays are fitted with low consumption DC coils and offer a large coil voltage range. | |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SNC001003C0202 |
Instructions and Manuals: | 1SBC101003M5501 |
Dimension Diagram: | FPTE307873 |
| |
Product Net Width: | 44 mm |
Product Net Depth / Length: | 130 mm |
Product Net Height: | 78 mm |
Product Net Weight: | 0.58 kg |
| |
Number of Auxiliary Contacts NO: | 8 |
Number of Auxiliary Contacts NC: | 0 |
Rated Operational Voltage: | Auxiliary Circuit 690 V |
Main Circuit 690 V | |
Rated Frequency (f): | Supply Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-5-1, q = 40 °C 16 A |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(380 / 400 V) 3 A | |
Short-Circuit Protective Devices: | Auxiliary Circuit - gG Type Fuses 10 A |
Maximum Electrical Switching Frequency: | 1200 cycles per hour |
Rated Operational Current DC-13 (Ie): | (24 V) 6 / 144 A |
(48 V) 2.8 / 134 A | |
(72 V) 1 / 72 A | |
(125 V) 0.55 / 69 A | |
(250 V) 0.3 / 75 A | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 8 kV |
Maximum Mechanical Switching Frequency: | 6000 cycles per hour |
Rated Control Circuit Voltage (Uc): | DC Operation 77 ... 143 V |
Coil Consumption: | Holding DC (Umin / Umax) 2.5 / 8.5 W |
Pull-in DC (Umin / Umax) 2.5 / 8.5 W | |
Operate Time: | Between Coil De-energization and NO Contact Opening 10 ... 17 ms |
Between Coil Energization and NO Contact Closing 50 ... 100 ms | |
Connecting Capacity Auxiliary Circuit: | Flexible with Cable End 0.75 ... 2.5 mm² |
Rigid Cable 1 ... 4 mm² | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
Terminal Type: | Screw Terminals |
| |
Ambient Air Temperature: | Close to Contactor for Storage -60 ... +80 °C |
Near Contactor for Operation in Free Air -40 ... 55 °C | |
Climatic Withstand: | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
Maximum Operating Altitude Permissible: | Without Derating 3000 m |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: A 20 g |
Closed, Shock Direction: B1 15 g | |
Closed, Shock Direction: C1 20 g | |
Closed, Shock Direction: C2 14 g | |
Open, Shock Direction: A 10 g | |
Open, Shock Direction: B1 5 g | |
Open, Shock Direction: C1 8 g | |
Open, Shock Direction: C2 8 g | |
Shock Direction: B2 10 g | |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CB Certificate: | CB_SE_66912A1 |
CCC Certificate: | CCC_2012010304558126 |
CQC Certificate: | CQC2012010304558126 |
CSA Certificate: | CSA_1041746 |
Declaration of Conformity - CCC: | 2020980303000256 |
Declaration of Conformity - CE: | 1SBD250808U1000 |
EAC Certificate: | EAC_RU C-FR ME77 B01006 |
Environmental Information: | 1SBD250127E1002 |
GOST Certificate: | GOST_POCCFRME77B07174 |
Instructions and Manuals: | 1SBC101003M5501 |
LOVAG Certificate: | LOVAG_FR04028 |
RoHS Information: | 1SBD250808U1000 |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 86 mm |
Package Level 1 Depth / Length: | 141 mm |
Package Level 1 Height: | 51 mm |
Package Level 1 Gross Weight: | 0.58 kg |
Package Level 1 EAN: | 3471522332622 |
Package Level 2 Units: | box 28 piece |
Package Level 2 Gross Weight: | 16.24 kg |
| |
Object Classification Code: | K |
ETIM 4: | EC000196 - Contactor relay |
ETIM 5: | EC000196 - Contactor relay |
ETIM 6: | EC000196 - Contactor relay |
ETIM 7: | EC000196 - Contactor relay |
eClass: | V11.0 : 27371018 |
UNSPSC: | 39121500 |