Article: TNL44E 17-32V DC

Article: TNL44E 17-32V DC

TNL44E 17-32V DC Contactor Relay
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration


























General Information
Extended Product Type: TNL44E 17-32V DC
Product ID: 1SBH143061R5144
EAN: 3471522330512
Catalog Description: TNL44E 17-32V DC Contactor Relay
Long Description: TNL... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 8-pole contactor relays (mechanically linked contact elements available) The width of 8-pole devices is identical to that of 4-pole devices only the depth is increased - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available TNL... contactor relays are fitted with low consumption DC coils and offer a large coil voltage range.only the depth is increased- Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected- Accessories: a wide range of accessories is availableTNL... contactor relays are fitted with low consumption DC coils and offer a large coil voltage range.
only the depth is increased- Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected- Accessories: a wide range of accessories is availableTNL... contactor relays are fitted with low consumption DC coils and offer a large coil voltage range.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Data Sheet, Technical Information: 1SNC001003C0202
Instructions and Manuals: 1SBC101003M5501
Dimension Diagram: FPTE307873

Dimensions
Product Net Width: 44 mm
Product Net Depth / Length: 130 mm
Product Net Height: 78 mm
Product Net Weight: 0.58 kg

Technical
Number of Auxiliary Contacts NO: 4
Number of Auxiliary Contacts NC: 4
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f): Supply Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-15 (Ie): (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A
Maximum Electrical Switching Frequency: 1200 cycles per hour
Rated Operational Current DC-13 (Ie): (24 V) 6 / 144 A
(48 V) 2.8 / 134 A
(72 V) 1 / 72 A
(125 V) 0.55 / 69 A
(250 V) 0.3 / 75 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 8 kV
Maximum Mechanical Switching Frequency: 6000 cycles per hour
Rated Control Circuit Voltage (Uc): DC Operation 17 ... 32 V
Coil Consumption: Holding DC (Umin / Umax) 2.5 / 8.5 W
Pull-in DC (Umin / Umax) 2.5 / 8.5 W
Operate Time: Between Coil De-energization and NC Contact Closing 16 ... 27 ms
Between Coil De-energization and NO Contact Opening 10 ... 17 ms
Between Coil Energization and NC Contact Opening 20 ... 70 ms
Between Coil Energization and NO Contact Closing 50 ... 100 ms
Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal Type: Screw Terminals

Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 55 °C
Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible: Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 20 g
Closed, Shock Direction: B1 15 g
Closed, Shock Direction: C1 20 g
Closed, Shock Direction: C2 14 g
Open, Shock Direction: A 10 g
Open, Shock Direction: B1 5 g
Open, Shock Direction: C1 8 g
Open, Shock Direction: C2 8 g
Shock Direction: B2 10 g
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
CB Certificate: CB_SE_66912A1
CCC Certificate: CCC_2012010304558126
CQC Certificate: CQC2012010304558126
CSA Certificate: CSA_1041746
Declaration of Conformity - CCC: 2020980303000256
Declaration of Conformity - CE: 1SBD250808U1000
EAC Certificate: EAC_RU C-FR ME77 B01006
Environmental Information: 1SBD250127E1002
GOST Certificate: GOST_POCCFRME77B07174
Instructions and Manuals: 1SBC101003M5501
RoHS Information: 1SBD250808U1000

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 86 mm
Package Level 1 Depth / Length: 141 mm
Package Level 1 Height: 51 mm
Package Level 1 Gross Weight: 0.58 kg
Package Level 1 EAN: 3471522330512
Package Level 2 Units: box 28 piece
Package Level 2 Gross Weight: 16.24 kg

Classifications
Object Classification Code: K
ETIM 4: EC000196 - Contactor relay
ETIM 5: EC000196 - Contactor relay
ETIM 6: EC000196 - Contactor relay
ETIM 7: EC000196 - Contactor relay
eClass: V11.0 : 27371018
UNSPSC: 39121500