Article: MS132-0.63K

We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | MS132-0.63K |
Product ID: | 1SAM350010R1004 |
EAN: | 4013614400346 |
Catalog Description: | MS132-0.63K Manual Motor Starter |
Long Description: | The MS132-0.63K manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 0.63 A with Push-in spring terminals. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The MS132-K manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The MS132-K manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362010 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100212C0203 |
Instructions and Manuals: | 2CDC131120M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
Time-Current Characteristic Curve: | 1SAM300505F0104 |
I²t Characteristic: | 1SAM300507F0001 |
1SAM300507F0003 | |
Cut-off Current Characteristic: | 1SAM300508F0001 |
1SAM300508F0003 | |
Marketing Video: | 2CDC131130V0201 |
| |
Product Net Width: | 45 mm |
Product Net Height: | 112 mm |
Product Net Depth / Length: | 87 mm |
Product Net Weight: | 0.256 kg |
| |
Rated Service Short-Circuit Breaking Capacity (Ics): | (230 V AC) 100 kA |
(250 V DC) 3 Poles in Series 10 kA | |
(400 V AC) 100 kA | |
(440 V AC) 100 kA | |
(500 V AC) 100 kA | |
(690 V AC) 100 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (230 V AC) 100 kA |
(400 V AC) 100 kA | |
(440 V AC) 100 kA | |
(500 V AC) 100 kA | |
(690 V AC) 100 kA | |
Rated Instantaneous Short-Circuit Current Setting (Ii): | 7.9 A |
Setting Range: | 0.40 ... 0.63 A |
Rated Operational Power AC-3 (Pe): | (400 V) Three Phase 0.18 kW |
Rated Operational Power AC-3e (Pe): | (400 V) Three Phase 0.18 kW |
Rated Operational Voltage: | Main Circuit 690 V AC |
Main Circuit 250 V DC | |
Rated Operational Current (Ie): | 0.63 A |
Rated Operational Current AC-3 (Ie): | 0.63 A |
Rated Operational Current AC-3e (Ie): | 0.63 A |
Rated Operational Current DC-5 (Ie): | 0.63 A |
Rated Frequency (f): | Main Circuit 50 Hz |
Main Circuit 60 Hz | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 6 kV |
Rated Insulation Voltage (Ui): | 690 V |
Power Loss: | at Rated Operating Conditions per Pole 0.7 W |
Number of Poles: | 3 |
Conventional Free-air Thermal Current (Ith): | Main Circuit 0.63 A |
Degree of Protection: | Housing IP20 |
Main Circuit Terminals IP20 | |
Pollution Degree: | 3 |
Electrical Durability: | 50000 cycle |
Mechanical Durability: | 100000 cycle |
Terminal Type: | Push-in Spring Terminals |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 0.5 ... 4 mm² |
Flexible with Insulated Ferrule 1x 0.5 ... 4 mm² | |
Flexible with Insulated Ferrule 2x 0.5 ... 2.5 mm² | |
Flexible 1/2x 0.75 ... 4 mm² | |
Solid 1/2x 1 ... 2.5 mm² | |
Stranded 1/2x 1 ... 6 mm² | |
Wire Stripping Length: | Main Circuit 12 mm |
Recommended Screw Driver: | Pozidriv 2 |
Mounting Position: | Position 1 to 6 |
Mounting on DIN Rail: | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | |
Minimum Mounting Distance: | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm |
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm | |
Electrical Conductive Board, Vertical 75 mm | |
Other Device Same Type, Horizontal 0 mm | |
Other Device Same Type, Vertical 150 mm | |
Actuator Type: | Rotary Handle |
Contact Position Indication: | ON / OFF / TRIP |
Standards: | IEC/EN 60947-1 |
IEC/EN 60947-2 | |
IEC/EN 60947-4-1 | |
UL 60947-1 | |
UL 60947-4-1 | |
Remarks: | UL508 Self-Protected Combination Motor Controller (Type E) in combination with terminal spacer TS1-M3-K |
Technical UL/CSA | |
Short-Circuit Current Rating (SCCR): | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA |
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA | |
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA | |
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA | |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA | |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Ampere Rating UL/CSA: | 0.63 A |
Full Load Amps Motor Use: | (200 V AC) Three Phase 0.63 A |
(208 V AC) Three Phase 0.63 A | |
(220 ... 240 V AC) Three Phase 0.63 A | |
(440 ... 480 V AC) Three Phase 0.63 A | |
(550 ... 600 V AC) Three Phase 0.63 A | |
Locked Rotor Amps: | (200 V AC) Three Phase 3.78 A |
(208 V AC) Three Phase 3.78 A | |
(220 ... 240 V AC) Three Phase 3.78 A | |
(440 ... 480 V AC) Three Phase 3.78 A | |
(550 ... 600 V AC) Three Phase 3.78 A | |
General Use Rating UL/CSA: | (600 V AC) 0.63 A |
Connecting Capacity Main Circuit UL/CSA: | Stranded 1/2x 18-10 AWG |
Stranded 1x 8 AWG | |
| |
Ambient Air Temperature: | Around the Enclosure 0 ... +40 °C |
Operation -25 ... +70 °C | |
Operation Compensated -25 ... +60 °C | |
Storage -50 ... +80 °C | |
Ambient Air Temperature Compensation: | Yes |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 25g |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5g / 3 ... 150 Hz |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
ABS Certificate: | 1SAA963001-0101 |
CB Certificate: | 1SAA963002-2002 |
CQC Certificate: | CQC2017010307034621 |
cUL Certificate: | cUL_E137861 |
Cut-off Current Characteristic: | 1SAM300508F0001 |
1SAM300508F0003 | |
Declaration of Conformity - CCC: | 2020980307004600 |
Declaration of Conformity - CE: | 1SAD938516-0125 |
EAC Certificate: | 1SAA963004-2701 |
Environmental Information: | 1SAC200049H0009 |
I²t Characteristic: | 1SAM300507F0001 |
1SAM300507F0003 | |
IECEx Certificate: | 1SAA963000-4001 |
Instructions and Manuals: | 2CDC131120M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
KC Certificate: | 1SAA963002-1502 |
RINA Certificate: | 1SAA963002-0802 |
RoHS Information: | 1SAD938516-0125 |
Time-Current Characteristic Curve: | 1SAM300505F0104 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 50 mm |
Package Level 1 Depth / Length: | 117 mm |
Package Level 1 Height: | 82 mm |
Package Level 1 Gross Weight: | 0.282 kg |
Package Level 1 EAN: | 4013614400346 |
Package Level 2 Units: | carton 28 piece |
Package Level 2 Width: | 280 mm |
Package Level 2 Depth / Length: | 395 mm |
Package Level 2 Height: | 210 mm |
Package Level 2 Gross Weight: | 14.026 kg |
Package Level 2 EAN: | 4013614522666 |
| |
Object Classification Code: | F |
ETIM 5: | EC000074 - Motor protective circuit-breaker |
ETIM 6: | EC000074 - Motor protection circuit-breaker |
ETIM 7: | EC000074 - Motor protection circuit-breaker |
eClass: | V11.0 : 27370401 |
UNSPSC: | 39121521 |
IDEA Granular Category Code (IGCC): | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |
E-Number (Finland): | 3707834 |
E-Number (Sweden): | 3110453 |