Article: MO132-6.3B

Article: MO132-6.3B

MO132-6.3B Manual Motor Starter Magnetic Only
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration

















































General Information
Extended Product Type: MO132-6.3B
Product ID: 1SAM360200R1009
EAN: 4013614521560
Catalog Description: MO132-6.3B Manual Motor Starter Magnetic Only
Long Description: Manual motor starters magnetic only are electromechanical protection devices for the main circuit, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They are used mainly to switch motors manually ON/OFF and protect them fuse-less against short-circuit.Fuse-less protection with a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off the motor within milliseconds. Fuse-less starter combinations are setup together with contactors and overload relays.designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85362010
Popular Downloads
Data Sheet, Technical Information: 1SBC100200C02__
Instructions and Manuals: 2CDC131034M6801
Instructions and Manuals (Part 2): 2CDC131060M0202
Time-Current Characteristic Curve: 1SAM300515F0008
I²t Characteristic: 1SAM300507F0001
1SAM300507F0003
Cut-off Current Characteristic: 1SAM300508F0001
1SAM300508F0003
Dimension Diagram: 1SAM300402F0001

Dimensions
Product Net Width: 45 mm
Product Net Height: 90 mm
Product Net Depth / Length: 86.75 mm
Product Net Weight: 0.265 kg

Technical
Rated Service Short-Circuit Breaking Capacity (Ics): (230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii): 78.8 A
Setting Range: None
Rated Operational Power AC-3 (Pe): (400 V) Three Phase 2.2 kW
Rated Operational Power AC-3e (Pe): (400 V) Three Phase 2.2 kW
Rated Operational Voltage: Main Circuit 690 V AC
Rated Operational Current (Ie): 6.3 A
Rated Operational Current AC-3 (Ie): 6.3 A
Rated Operational Current AC-3e (Ie): 6.3 A
Rated Frequency (f): Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp): Main Circuit 6 kV
Rated Insulation Voltage (Ui): 690 V
Number of Poles: 3
Conventional Free-air Thermal Current (Ith): Main Circuit 6.3 A
Degree of Protection: Housing IP20
Main Circuit Terminals IP10
Pollution Degree: 3
Electrical Durability: 50000 cycle
Mechanical Durability: 100000 cycle
Terminal Type: Screw Terminals
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Tightening Torque: Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length: Main Circuit 9 mm
Recommended Screw Driver: Pozidriv 2
Mounting Position: Position 1 to 6
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance: Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type: Rotary Handle
Contact Position Indication: ON / OFF / TRIP
Standards: IEC 60077-1 (applicable parts)
IEC 60077-2 (applicable parts)
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
Remarks: For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Technical UL/CSA
Short-Circuit Current Rating (SCCR): Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Ampere Rating UL/CSA: 6.3 A
Horsepower Rating UL/CSA: (200 V AC) Three Phase 1 Hp
(208 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 1.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 5 Hp
Full Load Amps Motor Use: (200 V AC) Three Phase 6.3 A
(208 V AC) Three Phase 6.3 A
(220 ... 240 V AC) Three Phase 6.3 A
(440 ... 480 V AC) Three Phase 4.8 A
(550 ... 600 V AC) Three Phase 6.1 A
Locked Rotor Amps: (200 V AC) Three Phase 37.8 A
(208 V AC) Three Phase 37.8 A
(220 ... 240 V AC) Three Phase 37.8 A
(440 ... 480 V AC) Three Phase 32 A
(550 ... 600 V AC) Three Phase 36.8 A
General Use Rating UL/CSA: (600 V AC) 6.3 A
Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA: Main Circuit 10 in·lb

Environmental
Ambient Air Temperature: Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation: No
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 3 ... 150 Hz
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
CB Certificate: 1SAA963002-2002
CQC Certificate: CQC2010010307387700
cUL Certificate: cUL_E137861
cUL_E345003
cULus Certificate: cUL_E137861
Cut-off Current Characteristic: 1SAM300508F0001
1SAM300508F0003
Declaration of Conformity - CCC: 2020980307003526
Declaration of Conformity - CE: 1SAD938506-0197
Environmental Information: 1SAC200050H0009
I²t Characteristic: 1SAM300507F0001
1SAM300507F0003
Instructions and Manuals: 2CDC131034M6801
Instructions and Manuals (Part 2): 2CDC131060M0202
RoHS Information: 1SAD938501-0197
Time-Current Characteristic Curve: 1SAM300515F0008
UL Certificate: UL_E137861
UL_E345003

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 92 mm
Package Level 1 Depth / Length: 95 mm
Package Level 1 Height: 50 mm
Package Level 1 Gross Weight: 0.28 kg
Package Level 1 EAN: 4013614521560
Package Level 2 Units: 30 piece
Package Level 2 Width: 280 mm
Package Level 2 Depth / Length: 395 mm
Package Level 2 Height: 210 mm
Package Level 2 Gross Weight: 13.386 kg
Package Level 2 EAN: 4013614523137

Classifications
Object Classification Code: F
ETIM 5: EC000074 - Motor protective circuit-breaker
ETIM 6: EC000074 - Motor protection circuit-breaker
ETIM 7: EC000074 - Motor protection circuit-breaker
eClass: V11.0 : 27370401
UNSPSC: 39121521
IDEA Granular Category Code (IGCC): 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
Accessories