Configuration
General Information | |
Extended Product Type: | MO132-32B |
Product ID: | 1SAM360200R1015 |
EAN: | 4013614521621 |
Catalog Description: | MO132-32B Manual Motor Starter Magnetic Only |
Long Description: | Manual motor starters magnetic only are electromechanical protection devices for the main circuit, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They are used mainly to switch motors manually ON/OFF and protect them fuse-less against short-circuit.Fuse-less protection with a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off the motor within milliseconds. Fuse-less starter combinations are setup together with contactors and overload relays.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2 |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362010 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100200C02__ |
Instructions and Manuals: | 2CDC131034M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
Time-Current Characteristic Curve: | 1SAM300515F0008 |
I²t Characteristic: | 1SAM300507F0001 |
1SAM300507F0003 | |
Cut-off Current Characteristic: | 1SAM300508F0001 |
1SAM300508F0003 | |
Dimension Diagram: | 1SAM300402F0002 |
| |
Product Net Width: | 45 mm |
Product Net Height: | 97.8 mm |
Product Net Depth / Length: | 86.55 mm |
Product Net Weight: | 0.31 kg |
| |
Rated Service Short-Circuit Breaking Capacity (Ics): | (230 V AC) 30 kA |
(400 V AC) 30 kA | |
(440 V AC) 30 kA | |
(500 V AC) 10 kA | |
(690 V AC) 3 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (230 V AC) 50 kA |
(400 V AC) 50 kA | |
(440 V AC) 30 kA | |
(500 V AC) 10 kA | |
(690 V AC) 3 kA | |
Rated Instantaneous Short-Circuit Current Setting (Ii): | 400 A |
Setting Range: | None |
Rated Operational Power AC-3 (Pe): | (400 V) Three Phase 15 kW |
Rated Operational Power AC-3e (Pe): | (400 V) Three Phase 15 kW |
Rated Operational Voltage: | Main Circuit 690 V AC |
Rated Operational Current (Ie): | 32 A |
Rated Operational Current AC-3 (Ie): | 32 A |
Rated Operational Current AC-3e (Ie): | 32 A |
Rated Frequency (f): | Main Circuit 50 Hz |
Main Circuit 60 Hz | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 6 kV |
Rated Insulation Voltage (Ui): | 690 V |
Number of Poles: | 3 |
Conventional Free-air Thermal Current (Ith): | Main Circuit 32 A |
Degree of Protection: | Housing IP20 |
Main Circuit Terminals IP10 | |
Pollution Degree: | 3 |
Electrical Durability: | 50000 cycle |
Mechanical Durability: | 100000 cycle |
Terminal Type: | Screw Terminals |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm² | |
Flexible 1/2x 1 ... 2.5 mm² | |
Flexible 1/2x 2.5 ... 6 mm² | |
Rigid 1/2x 1 ... 2.5 mm² | |
Rigid 1/2x 2.5 ... 6 mm² | |
Tightening Torque: | Main Circuit 2 N·m |
Wire Stripping Length: | Main Circuit 10 mm |
Recommended Screw Driver: | Pozidriv 2 |
Mounting Position: | Position 1 to 6 |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
Minimum Mounting Distance: | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm |
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm | |
Electrical Conductive Board, Vertical 75 mm | |
Other Device Same Type, Horizontal 0 mm | |
Other Device Same Type, Vertical 150 mm | |
Actuator Type: | Rotary Handle |
Contact Position Indication: | ON / OFF / TRIP |
Standards: | IEC 60077-1 (applicable parts) |
IEC 60077-2 (applicable parts) | |
IEC/EN 60947-1 | |
IEC/EN 60947-2 | |
IEC/EN 60947-4-1 | |
Remarks: | For overload protection of the motors, an appropriate thermal or electronic overload relays must be used |
Technical UL/CSA | |
Short-Circuit Current Rating (SCCR): | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA |
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA | |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA | |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Ampere Rating UL/CSA: | 32 A |
Horsepower Rating UL/CSA: | (200 V AC) Three Phase 7.5 Hp |
(208 V AC) Three Phase 10 Hp | |
(220 ... 240 V AC) Three Phase 10 Hp | |
(440 ... 480 V AC) Three Phase 20 Hp | |
(550 ... 600 V AC) Three Phase 25 Hp | |
Full Load Amps Motor Use: | (200 V AC) Three Phase 25.3 A |
(208 V AC) Three Phase 30.8 A | |
(220 ... 240 V AC) Three Phase 28 A | |
(440 ... 480 V AC) Three Phase 27 A | |
(550 ... 600 V AC) Three Phase 27 A | |
Locked Rotor Amps: | (200 V AC) Three Phase 146 A |
(208 V AC) Three Phase 179 A | |
(220 ... 240 V AC) Three Phase 162 A | |
(440 ... 480 V AC) Three Phase 145 A | |
(550 ... 600 V AC) Three Phase 146 A | |
General Use Rating UL/CSA: | (600 V AC) 32 A |
Connecting Capacity Main Circuit UL/CSA: | Flexible 1/2x 16-8 AWG |
Stranded 1/2x 16-8 AWG | |
Tightening Torque UL/CSA: | Main Circuit 18 in·lb |
| |
Ambient Air Temperature: | Around the Enclosure 0 ... +40 °C |
Operation -25 ... +60 °C | |
Storage -50 ... +80 °C | |
Ambient Air Temperature Compensation: | No |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 25g |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5g / 3 ... 150 Hz |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CB Certificate: | 1SAA963002-2002 |
CQC Certificate: | CQC2010010307387700 |
cUL Certificate: | cUL_E137861 |
cUL_E345003 | |
cULus Certificate: | cUL_E137861 |
Cut-off Current Characteristic: | 1SAM300508F0001 |
1SAM300508F0003 | |
Declaration of Conformity - CCC: | 2020980307003526 |
Declaration of Conformity - CE: | 1SAD938506-0197 |
Environmental Information: | 1SAC200050H0009 |
I²t Characteristic: | 1SAM300507F0001 |
1SAM300507F0003 | |
Instructions and Manuals: | 2CDC131034M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
RoHS Information: | 1SAD938501-0197 |
Time-Current Characteristic Curve: | 1SAM300515F0008 |
UL Certificate: | UL_E137861 |
UL_E345003 | |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 92 mm |
Package Level 1 Depth / Length: | 102 mm |
Package Level 1 Height: | 50 mm |
Package Level 1 Gross Weight: | 0.325 kg |
Package Level 1 EAN: | 4013614521621 |
Package Level 2 Units: | 30 piece |
Package Level 2 Width: | 280 mm |
Package Level 2 Depth / Length: | 395 mm |
Package Level 2 Height: | 210 mm |
Package Level 2 Gross Weight: | 13.386 kg |
Package Level 2 EAN: | 4013614523199 |
| |
Object Classification Code: | F |
ETIM 5: | EC000074 - Motor protective circuit-breaker |
ETIM 6: | EC000074 - Motor protection circuit-breaker |
ETIM 7: | EC000074 - Motor protection circuit-breaker |
eClass: | V11.0 : 27370401 |
UNSPSC: | 39121521 |
IDEA Granular Category Code (IGCC): | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |
Accessories |