Article: MO132-4.0

Article: MO132-4.0

MO132-4.0 Manual Motor Starter Magnetic Only
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration

















































General Information
Extended Product Type: MO132-4.0
Product ID: 1SAM360000R1008
EAN: 4013614400230
Catalog Description: MO132-4.0 Manual Motor Starter Magnetic Only
Long Description: The MO132-4.0 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 4.00 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85362010
Popular Downloads
Data Sheet, Technical Information: 2CDC131035D0202
Instructions and Manuals: 2CDC131034M6801
Instructions and Manuals (Part 2): 2CDC131060M0202
Time-Current Characteristic Curve: 1SAM300515F0008
I²t Characteristic: 1SAM300507F0001
1SAM300507F0003
Cut-off Current Characteristic: 1SAM300508F0001
1SAM300508F0003
Dimension Diagram: 1SAM300402F0001

Dimensions
Product Net Width: 45 mm
Product Net Height: 90 mm
Product Net Depth / Length: 86.75 mm
Product Net Weight: 0.265 kg

Technical
Rated Service Short-Circuit Breaking Capacity (Ics): (230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii): 50 A
Setting Range: None
Rated Operational Power AC-3 (Pe): (400 V) Three Phase 1.5 kW
Rated Operational Power AC-3e (Pe): (400 V) Three Phase 1.5 kW
Rated Operational Voltage: Main Circuit 690 V AC
Rated Operational Current (Ie): 4 A
Rated Operational Current AC-3 (Ie): 4 A
Rated Operational Current AC-3e (Ie): 4 A
Rated Frequency (f): Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp): Main Circuit 6 kV
Rated Insulation Voltage (Ui): 690 V
Power Loss: at Rated Operating Conditions per Pole 0.7 W
Number of Poles: 3
Conventional Free-air Thermal Current (Ith): Main Circuit 4 A
Degree of Protection: Housing IP20
Main Circuit Terminals IP10
Pollution Degree: 3
Electrical Durability: 50000 cycle
Mechanical Durability: 100000 cycle
Terminal Type: Screw Terminals
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Tightening Torque: Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length: Main Circuit 9 mm
Recommended Screw Driver: Pozidriv 2
Mounting Position: Position 1 to 6
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance: Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type: Rotary Handle
Contact Position Indication: ON / OFF / TRIP
Standards: IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
Remarks: For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Technical UL/CSA
Short-Circuit Current Rating (SCCR): Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Ampere Rating UL/CSA: 4 A
Horsepower Rating UL/CSA: (200 V AC) Three Phase 0.75 Hp
(208 V AC) Three Phase 0.75 Hp
(220 ... 240 V AC) Three Phase 1 Hp
(440 ... 480 V AC) Three Phase 2 Hp
(550 ... 600 V AC) Three Phase 3 Hp
Full Load Amps Motor Use: (200 V AC) Three Phase 4 A
(208 V AC) Three Phase 4 A
(220 ... 240 V AC) Three Phase 4 A
(440 ... 480 V AC) Three Phase 4 A
(550 ... 600 V AC) Three Phase 3.9 A
Locked Rotor Amps: (200 V AC) Three Phase 24 A
(208 V AC) Three Phase 24 A
(220 ... 240 V AC) Three Phase 24 A
(440 ... 480 V AC) Three Phase 24 A
(550 ... 600 V AC) Three Phase 25.6 A
General Use Rating UL/CSA: (600 V AC) 4 A
Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA: Main Circuit 10 in·lb

Environmental
Ambient Air Temperature: Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation: No
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 3 ... 150 Hz
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
ABS Certificate: 1SAA963001-0101
BV Certificate: 1SAA963001-0202
CB Certificate: 1SAA963002-2002
CQC Certificate: CQC2010010307387700
cUL Certificate: cUL_E137861
cUL_E345003
cULus Certificate: cUL_E137861
Cut-off Current Characteristic: 1SAM300508F0001
1SAM300508F0003
Declaration of Conformity - CCC: 2020980307003526
Declaration of Conformity - CE: 1SAD938509-0183
DNV GL Certificate: 1SAA963001-0304
EAC Certificate: 1SAA963000-2701
Environmental Information: 1SAC200049H0009
GOST Certificate: 1SAA963001-2702
I²t Characteristic: 1SAM300507F0001
1SAM300507F0003
Instructions and Manuals: 2CDC131034M6801
Instructions and Manuals (Part 2): 2CDC131060M0202
KC Certificate: 1SAA963002-1501
LR Certificate: 1SAA963001-0502
RINA Certificate: 1SAA963002-0802
RMRS Certificate: 1SAA918000-0704
RoHS Information: 1SAD938505-0183
Time-Current Characteristic Curve: 1SAM300515F0008
UL Certificate: UL_E137861
UL_E345003

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 92 mm
Package Level 1 Depth / Length: 95 mm
Package Level 1 Height: 50 mm
Package Level 1 Gross Weight: 0.28 kg
Package Level 1 EAN: 4013614400230
Package Level 2 Units: 40 piece
Package Level 2 Width: 280 mm
Package Level 2 Depth / Length: 395 mm
Package Level 2 Height: 210 mm
Package Level 2 Gross Weight: 11.586 kg
Package Level 2 EAN: 4013614443688

Classifications
Object Classification Code: F
ETIM 4: EC000074 - Motor protective circuit-breaker
ETIM 5: EC000074 - Motor protective circuit-breaker
ETIM 6: EC000074 - Motor protection circuit-breaker
ETIM 7: EC000074 - Motor protection circuit-breaker
eClass: V11.0 : 27370401
UNSPSC: 39121521
IDEA Granular Category Code (IGCC): 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
E-Number (Finland): 3705886
E-Number (Sweden): 3110036
Accessories