Article: MO165-20B

We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | MO165-20B |
Product ID: | 1SAM461200R1012 |
EAN: | 4013614522277 |
Catalog Description: | MO165-20B Manual Motor Starter Magnetic Only |
Long Description: | MO165-B is a compact and powerful range for starter protection up to 45 kW (400 V AC) / 80 A in width of 55 mm. Manual motor starters magnetic only are electromechanical protection devices for the main circuit, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They are used mainly to switch motors manually ON/OFF and protect them fuseless against short-circuits.Fuseless protection with a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off the motor within milliseconds. Fuse-less starter combinations are setup together with contactors and overload relays.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2 |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362010 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100200C02__ |
Data Sheet, Technical Information (Part 2): | 1SAM400506F0001 |
1SAM400507F0001 | |
Instructions and Manuals: | 2CDC131082M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
Dimension Diagram: | 1SAM400402F0001 |
| |
Product Net Width: | 55 mm |
Product Net Height: | 142.65 mm |
Product Net Depth / Length: | 122.1 mm |
Product Net Weight: | 0.95 kg |
| |
Rated Service Short-Circuit Breaking Capacity (Ics): | (230 V AC) 100 kA |
(250 V DC) 3 Poles in Series 100 kA | |
(400 V AC) 100 kA | |
(440 V AC) 75 kA | |
(500 V AC) 40 kA | |
(690 V AC) 10 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (230 V AC) 100 kA |
(250 V DC) 100 kA | |
(400 V AC) 100 kA | |
(440 V AC) 75 kA | |
(500 V AC) 40 kA | |
(690 V AC) 10 kA | |
Rated Instantaneous Short-Circuit Current Setting (Ii): | 300 A |
Setting Range: | None |
Rated Operational Power AC-3 (Pe): | (400 V) Three Phase 7.5 kW |
Rated Operational Power AC-3e (Pe): | (400 V) Three Phase 7.5 kW |
Rated Operational Voltage: | Main Circuit 690 V AC |
Main Circuit 250 V DC | |
Rated Operational Current (Ie): | 20 A |
Rated Operational Current AC-3 (Ie): | 20 A |
Rated Operational Current AC-3e (Ie): | 20 A |
Rated Operational Current DC-5 (Ie): | 20 A |
Rated Frequency (f): | Main Circuit 50 Hz |
Main Circuit 60 Hz | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 8 kV |
Rated Insulation Voltage (Ui): | 1000 V |
Power Loss: | 3.72 W |
Number of Poles: | 3 |
Conventional Free-air Thermal Current (Ith): | Main Circuit 20 A |
Degree of Protection: | Housing IP20 |
Main Circuit Terminals IP10 | |
Pollution Degree: | 3 |
Electrical Durability: | 25000 cycle |
Mechanical Durability: | 50000 cycle |
Terminal Type: | Screw Terminals |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 1 ... 35 mm² |
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm² | |
Flexible 1/2x 1 ... 35 mm² | |
Rigid 1/2x 1 ... 4 mm² | |
Solid 1/2x 1 ... 4 mm² | |
Stranded 1/2x 1 ... 50 mm² | |
Tightening Torque: | Main Circuit 4 N·m |
Wire Stripping Length: | Main Circuit 16 mm |
Recommended Screw Driver: | Pozidriv 2 |
Mounting Position: | Position 1 to 6 |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
Minimum Mounting Distance: | Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm |
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm | |
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm | |
Electrical Conductive Board, Vertical 75 mm | |
Other Device Same Type, Horizontal 0 mm | |
Other Device Same Type, Vertical 150 mm | |
Actuator Type: | Rotary Handle |
Contact Position Indication: | ON / OFF / TRIP |
Standards: | IEC 60077-1 (applicable parts) |
IEC 60077-2 (applicable parts) | |
IEC/EN 60947-1 | |
IEC/EN 60947-2 | |
IEC/EN 60947-4-1 | |
Remarks: | For overload protection of the motors, an appropriate thermal or electronic overload relays must be used |
Technical UL/CSA | |
Short-Circuit Current Rating (SCCR): | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA |
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA | |
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA | |
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA | |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA | |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Ampere Rating UL/CSA: | 20 A |
Horsepower Rating UL/CSA: | (200 V AC) Three Phase 5 Hp |
(208 V AC) Three Phase 5 Hp | |
(220 ... 240 V AC) Three Phase 5 Hp | |
(440 ... 480 V AC) Three Phase 10 Hp | |
(550 ... 600 V AC) Three Phase 15 Hp | |
Full Load Amps Motor Use: | (200 V AC) Three Phase 17.5 A |
(208 V AC) Three Phase 16.7 A | |
(220 ... 240 V AC) Three Phase 15.2 A | |
(440 ... 480 V AC) Three Phase 14 A | |
(550 ... 600 V AC) Three Phase 17 A | |
Locked Rotor Amps: | (200 V AC) Three Phase 105.8 A |
(208 V AC) Three Phase 102 A | |
(220 ... 240 V AC) Three Phase 92 A | |
(440 ... 480 V AC) Three Phase 81 A | |
(550 ... 600 V AC) Three Phase 93 A | |
General Use Rating UL/CSA: | (600 V AC) 20 A |
Connecting Capacity Main Circuit UL/CSA: | Flexible 1/2x 16-0 AWG |
Stranded 1/2x 16-0 AWG | |
Tightening Torque UL/CSA: | Main Circuit 35 in·lb |
| |
Ambient Air Temperature: | Operation -25 ... +60 °C |
Operation Compensated -25 ... +60 °C | |
Storage -50 ... +80 °C | |
Ambient Air Temperature Compensation: | No |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 25g |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5g / 3 ... 150 Hz |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CB Certificate: | 1SAA918002-2002 |
Declaration of Conformity - CE: | 1SAD938505-0198 |
Environmental Information: | 1SAC200051H0009 |
Instructions and Manuals: | 2CDC131082M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
RoHS Information: | 1SAD938501-0198 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 78 mm |
Package Level 1 Depth / Length: | 155 mm |
Package Level 1 Height: | 155 mm |
Package Level 1 Gross Weight: | 1.1 kg |
Package Level 1 EAN: | 4013614522277 |
Package Level 2 Units: | carton 12 piece |
Package Level 2 Width: | 330 mm |
Package Level 2 Depth / Length: | 400 mm |
Package Level 2 Height: | 320 mm |
Package Level 2 Gross Weight: | 13 kg |
Package Level 2 EAN: | 4013614521997 |
| |
Object Classification Code: | F |
ETIM 5: | EC000074 - Motor protective circuit-breaker |
ETIM 6: | EC000074 - Motor protection circuit-breaker |
ETIM 7: | EC000074 - Motor protection circuit-breaker |
eClass: | V11.0 : 27370401 |
UNSPSC: | 39121521 |
IDEA Granular Category Code (IGCC): | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |
Accessories |