Article: MO325-25

We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | MO325-25 |
Product ID: | 1SAM160000R1014 |
EAN: | 4013614302107 |
Catalog Description: | MO325-25 Manual Motor Starter Magnetic Only |
Long Description: | The MO325-25 manual motor starter magnetic only is a 54 mm width device with a rated operational current of Ie = 25.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter magnetic only offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC. Further features are the build-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362010 |
Popular Downloads | |
Data Sheet, Technical Information: | 2CDC131047D0201 |
Instructions and Manuals: | 2CDC131089M6801 |
| |
Product Net Width: | 54 mm |
Product Net Height: | 87.5 mm |
Product Net Depth / Length: | 75.5 mm |
Product Net Weight: | 0.34 kg |
| |
Rated Service Short-Circuit Breaking Capacity (Ics): | (230 V AC) 100 kA |
(400 V AC) 50 kA | |
(440 V AC) 30 kA | |
(500 V AC) 20 kA | |
(690 V AC) 3 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (230 V AC) 100 kA |
(400 V AC) 50 kA | |
(440 V AC) 30 kA | |
(500 V AC) 20 kA | |
(690 V AC) 3 kA | |
Rated Instantaneous Short-Circuit Current Setting (Ii): | 375 A |
Setting Range: | None |
Rated Operational Power AC-3 (Pe): | (400 V) Three Phase 12.5 kW |
Rated Operational Voltage: | Main Circuit 690 V AC |
Main Circuit 440 V DC | |
Rated Operational Current (Ie): | 25 A |
Rated Operational Current AC-3 (Ie): | 25 A |
Rated Frequency (f): | Main Circuit 50 Hz |
Main Circuit 60 Hz | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 6 kV |
Rated Insulation Voltage (Ui): | 690 V |
Power Loss: | at Rated Operating Conditions per Pole 1.7 W |
Number of Poles: | 3 |
Conventional Free-air Thermal Current (Ith): | Main Circuit 25 A |
Degree of Protection: | Housing IP20 |
Main Circuit Terminals IP20 | |
Pollution Degree: | 3 |
Electrical Durability: | 50000 cycle |
Mechanical Durability: | 100000 cycle |
Terminal Type: | Screw Terminals |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 0.75 ... 4 mm² |
Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm² | |
Flexible 1/2x 1 ... 6 mm² | |
Rigid 1/2x 1 ... 6 mm² | |
Tightening Torque: | Main Circuit 1.4 N·m |
Wire Stripping Length: | Main Circuit 10 mm |
Recommended Screw Driver: | M3.5 |
Pozidriv 2 | |
Mounting Position: | Position 1 to 6 |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
Actuator Type: | Rotary Handle |
Contact Position Indication: | ON / OFF |
Standards: | CSA 22.2 No. 14 |
IEC/EN 60947-1 | |
IEC/EN 60947-2 | |
IEC/EN 60947-4-1 | |
UL 508 | |
Remarks: | For overload protection of the motors, an appropriate thermal or electronic overload relays must be used |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Ampere Rating UL/CSA: | 25 A |
Horsepower Rating UL/CSA: | (220 ... 240 V AC) Three Phase 7.5 Hp |
(440 ... 480 V AC) Three Phase 15 Hp | |
(550 ... 600 V AC) Three Phase 20 Hp | |
Connecting Capacity Main Circuit UL/CSA: | Flexible 1/2x 14-8 AWG |
Stranded 1/2x 14-8 AWG | |
Tightening Torque UL/CSA: | Main Circuit 14 in·lb |
| |
Ambient Air Temperature: | Around the Enclosure 0 ... +40 °C |
Operation -25 ... +50 °C | |
Storage -50 ... +80 °C | |
Ambient Air Temperature Compensation: | No |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 15g |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5g / 10 ... 150 Hz |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CB Certificate: | 1SAA918000-2003 |
CQC Certificate: | CQC2017010307033534 |
cUL Certificate: | cUL_E137861 |
cULus Certificate: | E137861 |
Declaration of Conformity - CCC: | 2020980307003580 |
Declaration of Conformity - CE: | 1SAD938510-0037 |
Declaration of Conformity - UKCA: | 1SAD938500-1037 |
DNV Certificate: | 1SAA918000-0306 |
GL Certificate: | 1SAA918000-0403 |
GOST Certificate: | 1SAA918000-2703 |
Instructions and Manuals: | 2CDC131089M6801 |
LR Certificate: | 1SAA918000-0504 |
RINA Certificate: | 1SAA918000-0803 |
RMRS Certificate: | 1SAA918000-0704 |
RoHS Information: | 1SAD938507-0037 |
UL Certificate: | UL_E137861 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 92 mm |
Package Level 1 Depth / Length: | 58 mm |
Package Level 1 Height: | 78 mm |
Package Level 1 Gross Weight: | 0.37 kg |
Package Level 1 EAN: | 4013614302107 |
Package Level 2 Units: | carton 24 piece |
Package Level 2 Width: | 280 mm |
Package Level 2 Depth / Length: | 395 mm |
Package Level 2 Height: | 210 mm |
Package Level 2 Gross Weight: | 8.9 kg |
Package Level 2 EAN: | 4013614495069 |
| |
Object Classification Code: | F |
ETIM 4: | EC000074 - Motor protective circuit-breaker |
ETIM 5: | EC000074 - Motor protective circuit-breaker |
ETIM 6: | EC000074 - Motor protection circuit-breaker |
ETIM 7: | EC000074 - Motor protection circuit-breaker |
eClass: | V11.0 : 27370401 |
UNSPSC: | 39121521 |
IDEA Granular Category Code (IGCC): | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |