General Information | |
Extended Product Type: | MO165-73 |
Product ID: | 1SAM461000R1018 |
EAN: | 4013614536649 |
Catalog Description: | MO165-73 Manual Motor Starter Magnetic Only |
Long Description: | The MO165 manual motor starter magnetic only is a compact and powerful range for motor protection up to 45 kW (400 V) in width of 55 mm. The devices are used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starters magnetic only are suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as accessory. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362090 |
Popular Downloads | |
Data Sheet, Technical Information: | 2CDC131084D0201 |
Instructions and Manuals: | 2CDC131082M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
I²t Characteristic: | 1SAM400506F0001 |
Cut-off Current Characteristic: | 1SAM400507F0001 |
Dimension Diagram: | 1SAM400402F0001 |
| |
Product Net Width: | 55 mm |
Product Net Height: | 142.65 mm |
Product Net Depth / Length: | 122 mm |
Product Net Weight: | 1 kg |
| |
Rated Service Short-Circuit Breaking Capacity (Ics): | (230 V AC) 30 kA |
(250 V DC) 3 Poles in Series 100 kA | |
(400 V AC) 30 kA | |
(440 V AC) 18 kA | |
(500 V AC) 10 kA | |
(690 V AC) 6 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (230 V AC) 30 kA |
(250 V DC) 100 kA | |
(400 V AC) 30 kA | |
(440 V AC) 18 kA | |
(500 V AC) 10 kA | |
(690 V AC) 8 kA | |
Rated Instantaneous Short-Circuit Current Setting (Ii): | 1022 A |
Setting Range: | None |
Rated Operational Power AC-3 (Pe): | (400 V) Three Phase 37 kW |
Rated Operational Power AC-3e (Pe): | (400 V) Three Phase 37 kW |
Rated Operational Voltage: | Main Circuit 690 V AC |
Main Circuit 250 V DC | |
Rated Operational Current (Ie): | 73 A |
Rated Operational Current AC-3 (Ie): | 73 A |
Rated Operational Current AC-3e (Ie): | 73 A |
Rated Operational Current DC-5 (Ie): | 73 A |
Rated Frequency (f): | Main Circuit 50 Hz |
Main Circuit 60 Hz | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 8 kV |
Rated Insulation Voltage (Ui): | 1000 V |
Power Loss: | at Rated Operating Conditions per Pole 5.22 W |
Number of Poles: | 3 |
Conventional Free-air Thermal Current (Ith): | Main Circuit 73 A |
Degree of Protection: | Housing IP20 |
Main Circuit Terminals IP10 | |
Pollution Degree: | 3 |
Electrical Durability: | 20000 cycle |
Mechanical Durability: | 50000 cycle |
Terminal Type: | Screw Terminals |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 1 ... 35 mm² |
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm² | |
Flexible 1/2x 1 ... 35 mm² | |
Rigid 1/2x 1 ... 4 mm² | |
Solid 1/2x 1 ... 4 mm² | |
Stranded 1/2x 1 ... 50 mm² | |
Tightening Torque: | Main Circuit 4 N·m |
Wire Stripping Length: | Main Circuit 16 mm |
Recommended Screw Driver: | Pozidriv 2 |
Mounting Position: | Position 1 to 6 |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
Minimum Mounting Distance: | Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm |
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm | |
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm | |
Electrical Conductive Board, Vertical 75 mm | |
Other Device Same Type, Horizontal 0 mm | |
Other Device Same Type, Vertical 150 mm | |
Actuator Type: | Rotary Handle |
Contact Position Indication: | ON / OFF / TRIP |
Standards: | CSA 22.2 No. 14 |
IEC/EN 60947-1 | |
IEC/EN 60947-2 | |
IEC/EN 60947-4-1 | |
UL 60947-4-1 | |
Remarks: | For overload protection of the motors, an appropriate thermal or electronic overload relays must be used |
Technical UL/CSA | |
Short-Circuit Current Rating (SCCR): | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 50 kA |
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 10 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 50 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 10 kA | |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 50 kA | |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 10 kA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Ampere Rating UL/CSA: | 73 A |
Horsepower Rating UL/CSA: | (200 V AC) Three Phase 20 Hp |
(208 V AC) Three Phase 20 Hp | |
(220 ... 240 V AC) Three Phase 25 Hp | |
(440 ... 480 V AC) Three Phase 50 Hp | |
(550 ... 600 V AC) Three Phase 60 Hp | |
Full Load Amps Motor Use: | (110 ... 120 V AC) Three Phase 56 A |
(200 V AC) Three Phase 62.1 A | |
(208 V AC) Three Phase 59.4 A | |
(220 ... 240 V AC) Three Phase 68 A | |
(440 ... 480 V AC) Three Phase 65 A | |
(550 ... 600 V AC) Three Phase 62 A | |
Locked Rotor Amps: | (200 V AC) Three Phase 334 A |
(208 V AC) Three Phase 321 A | |
(220 ... 240 V AC) Three Phase 365 A | |
(440 ... 480 V AC) Three Phase 363 A | |
(550 ... 600 V AC) Three Phase 348 A | |
General Use Rating UL/CSA: | (600 V AC) 73 A |
Connecting Capacity Main Circuit UL/CSA: | Flexible 1/2x 16-0 AWG |
Stranded 1/2x 16-0 AWG | |
Tightening Torque UL/CSA: | Main Circuit 35 in·lb |
| |
Ambient Air Temperature: | Operation -25 ... +60 °C |
Operation Compensated -25 ... +60 °C | |
Storage -50 ... +80 °C | |
Ambient Air Temperature Compensation: | No |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 25g |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5g / 3 ... 150 Hz |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CB Certificate: | 1SAA918002-2002 |
CQC Certificate: | CQC2015010307760141 |
cUL Certificate: | cUL_E345003 |
cUL_E137861 | |
Cut-off Current Characteristic: | 1SAM400507F0001 |
Declaration of Conformity - CCC: | 2020980307003042 |
Declaration of Conformity - CE: | 1SAD938506-0191 |
EAC Certificate: | 1SAA963000-2701 |
Environmental Information: | 1SAC200051H0009 |
I²t Characteristic: | 1SAM400506F0001 |
IECEx Certificate: | 1SAA918000-4001 |
Instructions and Manuals: | 2CDC131082M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
RoHS Information: | 1SAD938504-0191 |
UL Certificate: | UL_E137861 |
UL_345003 | |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 78 mm |
Package Level 1 Depth / Length: | 155 mm |
Package Level 1 Height: | 155 mm |
Package Level 1 Gross Weight: | 1.1 kg |
Package Level 1 EAN: | 4013614536649 |
Package Level 2 Units: | carton 12 piece |
Package Level 2 Width: | 330 mm |
Package Level 2 Depth / Length: | 400 mm |
Package Level 2 Height: | 320 mm |
Package Level 2 Gross Weight: | 13 kg |
Package Level 2 EAN: | 4013614537837 |
| |
Object Classification Code: | F |
ETIM 5: | EC000074 - Motor protective circuit-breaker |
ETIM 6: | EC000074 - Motor protection circuit-breaker |
ETIM 7: | EC000074 - Motor protection circuit-breaker |
eClass: | V11.0 : 27370401 |
UNSPSC: | 39121521 |
IDEA Granular Category Code (IGCC): | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |
E-Number (Finland): | 3708085 |