Article: NFZ62E-30

Article: NFZ62E-30

NFZ62E-30 24VDC Contactor Relay
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration






























General Information
Extended Product Type: NFZ62E-30
Product ID: 1SBH136001R3062
EAN: 3471523102194
Catalog Description: NFZ62E-30 24VDC Contactor Relay
Long Description: NFZ contactor relays are used for switching auxiliary and control circuits. NFZ contactor relays with coil 30 include a 24 V DC electronic coil interface with a built-in surge suppression, obtaining a reduced holding coil consumption up to 1.7 W for a low panel energy consumption and a direct control by PLC-output ≥ 250 mA 24 V DC, without need of additional interface relay. Only NFZ..-30 contactor relays need to respect the polarity on the coil terminals (A1+ and A2-). Poles: 8-pole contactor relays with a non-removable front-mounted auxiliary contact block (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and including the "Mechanically Linked" symbol on the contactor relay side).

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Instructions and Manuals: 1SBC101053M6801

Dimensions
Product Net Width: 45 mm
Product Net Depth / Length: 130.5 mm
Product Net Height: 86 mm
Product Net Weight: 0.49 kg

Technical
Number of Auxiliary Contacts NO: 6
Number of Auxiliary Contacts NC: 2
Rated Operational Voltage: Auxiliary Circuit 690 V
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-15 (Ie): (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Short-time Withstand Current (Icw): for 0.1 s 140 A
for 1 s 100 A
Maximum Electrical Switching Frequency: (AC-15) 1200 cycles per hour
(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie): (24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui): acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Mechanical Switching Frequency: 6000 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz / 60 Hz 100 ... 250 V
DC Operation 24 V
Operate Time: Between Coil De-energization and NC Contact Closing 22 ... 57 ms
Between Coil De-energization and NO Contact Opening 17 ... 29 ms
Between Coil Energization and NC Contact Opening 20 ... 35 ms
Between Coil Energization and NO Contact Closing 27 ... 53 ms
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length: Auxiliary Circuit 10 mm
Control Circuit 10 mm
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal Type: Screw Terminals

Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
Climatic Withstand: Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible: 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 4 g closed position / 2 g open position
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
CB Certificate: CB_SE-93051M2
CCC Certificate: 2020980303000185
CQC Certificate: CQC2019010303267993
cUL Certificate: UL_20180227_E252354_2_1
Declaration of Conformity - CCC: CQC2011010303465426
Declaration of Conformity - CE: 1SBD250005U1000
DNV Certificate: DNV-GL_TAE00001BV-3
DNV GL Certificate: DNV-GL_TAE00001BV-3
EAC Certificate: EAC_RU C-FR ME77 B03544
GL Certificate: DNV-GL_TAE00001BV-3
Instructions and Manuals: 1SBC101053M6801
RINA Certificate: RINA_ELE240318XG
RMRS Certificate: RMRS_1802702280
RoHS Information: 1SBD250005U1000

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 96 mm
Package Level 1 Depth / Length: 145 mm
Package Level 1 Height: 50 mm
Package Level 1 Gross Weight: 0.54 kg
Package Level 1 EAN: 3471523102194
Package Level 2 Units: crate 12 piece
Package Level 2 Width: 51 mm
Package Level 2 Depth / Length: 98 mm
Package Level 2 Height: 148 mm
Package Level 2 Gross Weight: 6.48 kg
Package Level 3 Units: 576 piece

Classifications
Object Classification Code: K
ETIM 4: EC000196 - Contactor relay
ETIM 5: EC000196 - Contactor relay
ETIM 6: EC000196 - Contactor relay
ETIM 7: EC000196 - Contactor relay
eClass: V11.0 : 27371003
UNSPSC: 39121529