Article: NFZ62EK-21

Article: NFZ62EK-21

NFZ62EK-21 24-60V50/60HZ 20-60VDC Contactor Relay
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration
































General Information
Extended Product Type: NFZ62EK-21
Product ID: 1SBH136005R2162
EAN: 3471523153714
Catalog Description: NFZ62EK-21 24-60V50/60HZ 20-60VDC Contactor Relay
Long Description: NFZ..K contactor relays are used for switching auxiliary and control circuits. NFZ contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change NFZ contactor relays allow direct control by PLC-output ≥ 24 V DC 500 mA and obtain a reduced holding coil consumption. NFZ contactor relays withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz NFZ contactor relays have built-in surge protection and do not require additional surge suppressors. NFZ..K include Push-in Spring terminals. Only one push is all you need for extremely fast wiring: faster than ever installation, easier than ever wiring, reliable as ever connections. Poles: 8-pole contactor relays with a non-removable front-mounted auxiliary contact block (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and including the "Mechanically Linked" symbol on the contactor relay side).

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Instructions and Manuals: 1SBC101054M6801

Dimensions
Product Net Width: 45 mm
Product Net Depth / Length: 110.5 mm
Product Net Height: 92.3 mm
Product Net Weight: 0.36 kg

Technical
Number of Auxiliary Contacts NO: 6
Number of Auxiliary Contacts NC: 2
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-15 (Ie): (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Short-time Withstand Current (Icw): for 0.1 s 140 A
for 1 s 100 A
Maximum Electrical Switching Frequency: (AC-15) 1200 cycles per hour
(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie): (24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui): acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Mechanical Switching Frequency: 6000 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 24 ... 60 V
50 Hz / 60 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Operate Time: Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm²
Flexible 1/2x 0.5 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm²
Flexible 1/2x 0.5 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length: Auxiliary Circuit 10 mm
Control Circuit 10 mm
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal Type: Push-in Spring Terminals

Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
Climatic Withstand: Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible: 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 4 g closed position / 2 g open position
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
CB Certificate: CB_SE-93051M2
CCC Certificate: 2020980303000185
CQC Certificate: CQC2019010303267993
cUL Certificate: UL_20180227_E252354_2_1
Declaration of Conformity - CCC: CQC2011010303465426
Declaration of Conformity - CE: 1SBD250005U1000
DNV Certificate: DNV-GL_TAE00001BV-3
DNV GL Certificate: DNV-GL_TAE00001BV-3
GL Certificate: DNV-GL_TAE00001BV-3
Instructions and Manuals: 1SBC101054M6801
RINA Certificate: RINA_ELE240318XG
RMRS Certificate: RMRS_1802702280
RoHS Information: 1SBD250005U1000

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 91 mm
Package Level 1 Depth / Length: 111 mm
Package Level 1 Height: 45 mm
Package Level 1 Gross Weight: 0.379 kg
Package Level 1 EAN: 3471523153714
Package Level 2 Units: box 18 piece
Package Level 2 Width: 250 mm
Package Level 2 Depth / Length: 300 mm
Package Level 2 Height: 315 mm
Package Level 2 Gross Weight: 17.055 kg
Package Level 3 Units: 1080 piece

Classifications
Object Classification Code: K
ETIM 4: EC000196 - Contactor relay
ETIM 5: EC000196 - Contactor relay
ETIM 6: EC000196 - Contactor relay
ETIM 7: EC000196 - Contactor relay
eClass: V11.0 : 27371003
UNSPSC: 39121500
E-Number (Finland): 3708018