Article: MS165-42

Article: MS165-42

MS165-42 Manual Motor Starter
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration





















































General Information
Extended Product Type: MS165-42
Product ID: 1SAM451000R1015
EAN: 4013614486098
Catalog Description: MS165-42 Manual Motor Starter
Long Description: MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter (also known as motor protection circuit breaker or manual motor protector) is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. Theseare suitable throughout the MS116/MS132/MS165 range.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85362010
Popular Downloads
Data Sheet, Technical Information: 2CDC131083D0201
Instructions and Manuals: 2CDC131081M6801
Instructions and Manuals (Part 2): 2CDC131060M0202
Time-Current Characteristic Curve: 1SAM400505F0005
I²t Characteristic: 1SAM400506F0001
Cut-off Current Characteristic: 1SAM400507F0001
Dimension Diagram: 1SAM400401F0001

Dimensions
Product Net Width: 55 mm
Product Net Height: 142.65 mm
Product Net Depth / Length: 122.1 mm
Product Net Weight: 0.97 kg

Technical
Rated Service Short-Circuit Breaking Capacity (Ics): (230 V AC) 50 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
Rated Instantaneous Short-Circuit Current Setting (Ii): 630 A
Setting Range: 30 ... 42 A
Rated Operational Power AC-3 (Pe): (400 V) Three Phase 22 kW
Rated Operational Power AC-3e (Pe): (400 V) Three Phase 22 kW
Rated Operational Voltage: Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie): 42 A
Rated Operational Current AC-3 (Ie): 42 A
Rated Operational Current AC-3e (Ie): 42 A
Rated Operational Current DC-5 (Ie): 42 A
Rated Frequency (f): Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Rated Insulation Voltage (Ui): 1000 V
Power Loss: at Rated Operating Conditions per Pole 2.79 W
Number of Poles: 3
Conventional Free-air Thermal Current (Ith): Main Circuit 42 A
Degree of Protection: Housing IP20
Main Circuit Terminals IP10
Pollution Degree: 3
Electrical Durability: 25000 cycle
Mechanical Durability: 50000 cycle
Terminal Type: Screw Terminals
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Tightening Torque: Main Circuit 4 N·m
Wire Stripping Length: Main Circuit 16 mm
Recommended Screw Driver: Pozidriv 2
Mounting Position: Position 1 to 6
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance: Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type: Rotary Handle
Contact Position Indication: ON / OFF / TRIP
Standards: CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
Technical UL/CSA
Short-Circuit Current Rating (SCCR): Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Ampere Rating UL/CSA: 42 A
Horsepower Rating UL/CSA: (200 V AC) Three Phase 10 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 40 Hp
Full Load Amps Motor Use: (200 V AC) Three Phase 32.2 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 42 A
(440 ... 480 V AC) Three Phase 40 A
(550 ... 600 V AC) Three Phase 41 A
Locked Rotor Amps: (200 V AC) Three Phase 186.3 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 232 A
(440 ... 480 V AC) Three Phase 218 A
(550 ... 600 V AC) Three Phase 232 A
General Use Rating UL/CSA: (600 V AC) 42 A
Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Tightening Torque UL/CSA: Main Circuit 35 in·lb

Environmental
Ambient Air Temperature: Operation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation: Yes
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 3 ... 150 Hz
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
ABS Certificate: 1SAA963002-0101
ATEX Certificate: 1SAA918001-3901
BV Certificate: 1SAA963002-0201
CB Certificate: 1SAA918002-2002
CQC Certificate: CQC2015010307760141
cUL Certificate: cUL_E345003
cUL_E137861
Cut-off Current Characteristic: 1SAM400507F0001
Declaration of Conformity - CCC: 2020980307003042
Declaration of Conformity - CE: 1SAD938507-0190
DNV GL Certificate: 1SAA963002-0301
EAC Certificate: 1SAA963000-2701
Environmental Information: 1SAC200051H0009
I²t Characteristic: 1SAM400506F0001
IECEx Certificate: 1SAA918000-4001
Instructions and Manuals: 2CDC131081M6801
Instructions and Manuals (Part 2): 2CDC131060M0202
KC Certificate: 1SAA963001-1501
LR Certificate: 1SAA918001-0501
RMRS Certificate: 1SAA918000-0704
RoHS Information: 1SAD938505-0190
Time-Current Characteristic Curve: 1SAM400505F0005
UL Certificate: UL_E137861
UL_345003

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 78 mm
Package Level 1 Depth / Length: 155 mm
Package Level 1 Height: 155 mm
Package Level 1 Gross Weight: 1.1 kg
Package Level 1 EAN: 4013614486098
Package Level 2 Units: carton 12 piece
Package Level 2 Width: 330 mm
Package Level 2 Depth / Length: 400 mm
Package Level 2 Height: 320 mm
Package Level 2 Gross Weight: 13 kg
Package Level 2 EAN: 4013614503955

Classifications
Object Classification Code: F
ETIM 5: EC000074 - Motor protective circuit-breaker
ETIM 6: EC000074 - Motor protection circuit-breaker
ETIM 7: EC000074 - Motor protection circuit-breaker
eClass: V11.0 : 27370401
UNSPSC: 39121521
IDEA Granular Category Code (IGCC): 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
E-Number (Finland): 3707288
E-Number (Sweden): 3110055
Accessories