Article: MS132-20T

Article: MS132-20T

MS132-20T Circuit Breaker for Primary Transformer Protection
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration
























General Information
Extended Product Type: MS132-20T
Product ID: 1SAM340000R1013
EAN: 4013614485039
Catalog Description: MS132-20T Circuit Breaker for Primary Transformer Protection
Long Description: The circuit breaker for transformer protection MS132-20T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 20 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85362010
Popular Downloads
Data Sheet, Technical Information: 2CDC131058D0201
Instructions and Manuals: 2CDC131057M6801
Instructions and Manuals (Part 2): 2CDC131060M0202
Time-Current Characteristic Curve: 1SAM300535F0013
I²t Characteristic: 1SAM300517F0001
Dimension Diagram: 1SAM300402F0002

Dimensions
Product Net Width: 45 mm
Product Net Height: 97.8 mm
Product Net Depth / Length: 86.05 mm
Product Net Weight: 0.31 kg

Technical
Rated Service Short-Circuit Breaking Capacity (Ics): (230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (400 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii): 400 A
Setting Range: 16 ... 20 A
Rated Operational Voltage: Main Circuit 690 V AC
Rated Operational Current (Ie): 20 A
Rated Frequency (f): Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp): Main Circuit 6 kV
Rated Insulation Voltage (Ui): 690 V
Power Loss: at Rated Operating Conditions per Pole 1 W
Number of Poles: 3
Conventional Free-air Thermal Current (Ith): Main Circuit 20 A
Degree of Protection: Housing IP20
Main Circuit Terminals IP10
Pollution Degree: 3
Electrical Durability: 50000 cycle
Mechanical Durability: 100000 cycle
Terminal Type: Screw Terminals
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Tightening Torque: Main Circuit 2 N·m
Wire Stripping Length: Main Circuit 10 mm
Recommended Screw Driver: M4
Pozidriv 2
Mounting Position: Position 1 to 6
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance: Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 9 mm
Other Device Same Type, Vertical 150 mm
Actuator Type: Rotary Handle
Contact Position Indication: ON / OFF / TRIP
Standards: IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
Technical UL/CSA
Short-Circuit Current Rating (SCCR): Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Ampere Rating UL/CSA: 20 A
Horsepower Rating UL/CSA: (120 V AC) Single Phase 1.5 Hp
(220 ... 240 V AC) Single Phase 3 Hp
Full Load Amps Motor Use: (120 V AC) Single Phase 20 A
(220 ... 240 V AC) Single Phase 17 A
Locked Rotor Amps: (120 V AC) Single Phase 120 A
(220 ... 240 V AC) Single Phase 120 A
Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Tightening Torque UL/CSA: Main Circuit 16 in·lb

Environmental
Ambient Air Temperature: Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation: Yes
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 3 ... 150 Hz
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
CQC Certificate: CQC2010010307387700
cUL Certificate: cUL_E137861
cULus Certificate: cUL_E137861
cUR Certificate: cUL_E137861
Declaration of Conformity - CCC: 2020980307003526
Declaration of Conformity - CE: 1SAD938508-0188
Environmental Information: 1SAC200049H0009
GOST Certificate: 1SAA937000-2703
I²t Characteristic: 1SAM300517F0001
Instructions and Manuals: 2CDC131057M6801
Instructions and Manuals (Part 2): 2CDC131060M0202
KC Certificate: 1SAA963002-1502
RMRS Certificate: 1SAA918000-0704
RoHS Information: 1SAD938503-0188
Time-Current Characteristic Curve: 1SAM300535F0013

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 92 mm
Package Level 1 Depth / Length: 102 mm
Package Level 1 Height: 50 mm
Package Level 1 Gross Weight: 0.325 kg
Package Level 1 EAN: 4013614485039
Package Level 2 Units: 40 piece
Package Level 2 Width: 280 mm
Package Level 2 Depth / Length: 395 mm
Package Level 2 Height: 210 mm
Package Level 2 Gross Weight: 13.386 kg
Package Level 2 EAN: 4013614487231

Classifications
Object Classification Code: F
ETIM 4: EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 5: EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 6: EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 7: EC000228 - Power circuit-breaker for trafo/generator/installation protection
eClass: V11.0 : 27370409
UNSPSC: 39121601
IDEA Granular Category Code (IGCC): 4813 >> Circuit breakers
E-Number (Finland): 3707275