Article: MS132-4.0KB

We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | MS132-4.0KB |
Product ID: | 1SAM350210R1008 |
EAN: | 4013614534980 |
Catalog Description: | MS132-4.0KB Manual Motor Starter |
Long Description: | MS132-KB with Push-in Spring terminals is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory. These are suitable throughout the MS132-B/MS165-B range.– designed in accordance to the applicable parts of IEC 60077 standard– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)– usable according to European fire and smoke safety standard EN 45545-2 |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362010 |
Popular Downloads | |
Data Sheet, Technical Information: | 2CDC131021D0201 |
Instructions and Manuals: | 2CDC131120M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
Time-Current Characteristic Curve: | 1SAM300505F0108 |
I²t Characteristic: | 1SAM300507F0001 |
1SAM300507F0003 | |
Cut-off Current Characteristic: | 1SAM300508F0001 |
1SAM300508F0003 | |
Marketing Video: | 2CDC131130V0201 |
| |
Product Net Width: | 112 mm |
Product Net Height: | 45 mm |
Product Net Depth / Length: | 87 mm |
Product Net Weight: | 0.286 kg |
| |
Rated Service Short-Circuit Breaking Capacity (Ics): | (230 V AC) 100 kA |
(250 V DC) 3 Poles in Series 10 kA | |
(400 V AC) 100 kA | |
(440 V AC) 30 kA | |
(500 V AC) 20 kA | |
(690 V AC) 3 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (230 V AC) 100 kA |
(400 V AC) 100 kA | |
(440 V AC) 30 kA | |
(500 V AC) 20 kA | |
(690 V AC) 3 kA | |
Rated Instantaneous Short-Circuit Current Setting (Ii): | 50 A |
Setting Range: | 2.5 ... 4.0 A |
Rated Operational Power AC-3 (Pe): | (400 V) Three Phase 1.5 kW |
Rated Operational Power AC-3e (Pe): | (400 V) Three Phase 1.5 kW |
Rated Operational Voltage: | Main Circuit 690 V AC |
Main Circuit 250 V DC | |
Rated Operational Current (Ie): | 4 A |
Rated Operational Current AC-3 (Ie): | 4 A |
Rated Operational Current AC-3e (Ie): | 4 A |
Rated Operational Current DC-5 (Ie): | 4 A |
Rated Frequency (f): | Main Circuit 50 Hz |
Main Circuit 60 Hz | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 6 kV |
Rated Insulation Voltage (Ui): | 690 V |
Number of Poles: | 3 |
Conventional Free-air Thermal Current (Ith): | Main Circuit 4 A |
Degree of Protection: | Housing IP20 |
Main Circuit Terminals IP20 | |
Pollution Degree: | 3 |
Electrical Durability: | 50000 cycle |
Mechanical Durability: | 100000 cycle |
Terminal Type: | Push-in Spring Terminals |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 0.5 ... 4 mm² |
Flexible with Insulated Ferrule 1x 0.5 ... 4 mm² | |
Flexible with Insulated Ferrule 2x 0.5 ... 2.5 mm² | |
Flexible 1/2x 0.75 ... 4 mm² | |
Solid 1/2x 1 ... 2.5 mm² | |
Stranded 1/2x 1 ... 6 mm² | |
Mounting Position: | Position 1 to 6 |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
Minimum Mounting Distance: | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm |
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm | |
Electrical Conductive Board, Vertical 75 mm | |
Other Device Same Type, Horizontal 0 mm | |
Other Device Same Type, Vertical 150 mm | |
Actuator Type: | Rotary Handle |
Contact Position Indication: | ON / OFF / TRIP |
Standards: | IEC 60077-1 (applicable parts) |
IEC 60077-2 (applicable parts) | |
IEC/EN 60947-1 | |
IEC/EN 60947-2 | |
IEC/EN 60947-4-1 | |
Remarks: | UL508 Self-Protected Combination Motor Controller (Type E) in combination with terminal spacer TS1-M3-K |
Technical UL/CSA | |
Short-Circuit Current Rating (SCCR): | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA |
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA | |
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA | |
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA | |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA | |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Ampere Rating UL/CSA: | 4 A |
Horsepower Rating UL/CSA: | (200 V AC) Three Phase 0.75 Hp |
(208 V AC) Three Phase 0.75 Hp | |
(220 ... 240 V AC) Three Phase 1 Hp | |
(440 ... 480 V AC) Three Phase 2 Hp | |
(550 ... 600 V AC) Three Phase 3 Hp | |
Full Load Amps Motor Use: | (200 V AC) Three Phase 4 A |
(208 V AC) Three Phase 4 A | |
(220 ... 240 V AC) Three Phase 4 A | |
(440 ... 480 V AC) Three Phase 4 A | |
(550 ... 600 V AC) Three Phase 3.9 A | |
Locked Rotor Amps: | (200 V AC) Three Phase 24 A |
(208 V AC) Three Phase 24 A | |
(220 ... 240 V AC) Three Phase 24 A | |
(440 ... 480 V AC) Three Phase 24 A | |
(550 ... 600 V AC) Three Phase 25.6 A | |
General Use Rating UL/CSA: | (600 V AC) 4 A |
Connecting Capacity Main Circuit UL/CSA: | Stranded 1/2x 18-10 AWG |
Stranded 1x 8 AWG | |
| |
Ambient Air Temperature: | Around the Enclosure 0 ... +40 °C |
Operation -25 ... +70 °C | |
Operation Compensated -25 ... +60 °C | |
Storage -50 ... +80 °C | |
Ambient Air Temperature Compensation: | Yes |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 25g |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5g / 3 ... 150 Hz |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
cUL Certificate: | cUL_E137861 |
Cut-off Current Characteristic: | 1SAM300508F0001 |
1SAM300508F0003 | |
Declaration of Conformity - CE: | 1SAD938506-0197 |
Environmental Information: | 1SAC200050H0009 |
I²t Characteristic: | 1SAM300507F0001 |
1SAM300507F0003 | |
Instructions and Manuals: | 2CDC131120M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
KC Certificate: | 1SAA963002-1502 |
RoHS Information: | 1SAD938506-0197 |
Time-Current Characteristic Curve: | 1SAM300505F0108 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 82 mm |
Package Level 1 Depth / Length: | 117 mm |
Package Level 1 Height: | 50 mm |
Package Level 1 Gross Weight: | 0.312 kg |
Package Level 1 EAN: | 4013614534980 |
Package Level 2 Units: | carton 28 piece |
Package Level 2 Width: | 280 mm |
Package Level 2 Depth / Length: | 395 mm |
Package Level 2 Height: | 210 mm |
Package Level 2 Gross Weight: | 14.026 kg |
Package Level 2 EAN: | 4013614535338 |
| |
Object Classification Code: | F |
ETIM 5: | EC000074 - Motor protective circuit-breaker |
ETIM 6: | EC000074 - Motor protection circuit-breaker |
ETIM 7: | EC000074 - Motor protection circuit-breaker |
eClass: | V11.0 : 27370401 |
UNSPSC: | 39121521 |
IDEA Granular Category Code (IGCC): | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |
Accessories |