Article: MS132-10KT

Article: MS132-10KT
MS132-10KT Circuit Breaker for Primary Transformer Protection
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | MS132-10KT |
Product ID: | 1SAM340010R1010 |
EAN: | 4013614535208 |
Catalog Description: | MS132-10KT Circuit Breaker for Primary Transformer Protection |
Long Description: | The circuit breaker for transformer protection MS132-10KT is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 10 A with Push-In Spring terminals. It allows fuseless protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362010 |
Popular Downloads | |
Data Sheet, Technical Information: | 2CDC131058D0201 |
Instructions and Manuals: | 2CDC131158M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
Time-Current Characteristic Curve: | 1SAM300535F0010 |
I²t Characteristic: | 1SAM300517F0001 |
Marketing Video: | 2CDC131130V0201 |
| |
Product Net Width: | 45 mm |
Product Net Height: | 112 mm |
Product Net Depth / Length: | 87 mm |
Product Net Weight: | 0.296 kg |
| |
Rated Service Short-Circuit Breaking Capacity (Ics): | (230 V AC) 100 kA |
(400 V AC) 100 kA | |
(440 V AC) 30 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (400 V AC) 100 kA |
Rated Instantaneous Short-Circuit Current Setting (Ii): | 200 A |
Setting Range: | 6.3 ... 10 A |
Rated Operational Voltage: | Main Circuit 690 V AC |
Rated Operational Current (Ie): | 10 A |
Rated Frequency (f): | Main Circuit 50 Hz |
Main Circuit 60 Hz | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 6 kV |
Rated Insulation Voltage (Ui): | 690 V |
Power Loss: | at Rated Operating Conditions per Pole 0.7 W |
Number of Poles: | 3 |
Conventional Free-air Thermal Current (Ith): | Main Circuit 10 A |
Degree of Protection: | Housing IP20 |
Main Circuit Terminals IP20 | |
Pollution Degree: | 3 |
Electrical Durability: | 50000 cycle |
Mechanical Durability: | 100000 cycle |
Terminal Type: | Push-in Spring Terminals |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1/2x 0.5 ... 4 mm² |
Flexible with Insulated Ferrule 1x 0.5 ... 4 mm² | |
Flexible with Insulated Ferrule 2x 0.5 ... 2.5 mm² | |
Flexible 1/2x 0.75 ... 4 mm² | |
Solid 1/2x 1 ... 2.5 mm² | |
Stranded 1/2x 1 ... 6 mm² | |
Wire Stripping Length: | Main Circuit 12 mm |
Mounting Position: | Position 1 to 6 |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
Minimum Mounting Distance: | Electrical Conductive Board, Vertical 75 mm |
Other Device Same Type, Horizontal 9 mm | |
Other Device Same Type, Vertical 150 mm | |
Actuator Type: | Rotary Handle |
Contact Position Indication: | ON / OFF / TRIP |
Standards: | IEC/EN 60947-1 |
IEC/EN 60947-2 | |
IEC/EN 60947-4-1 | |
Technical UL/CSA | |
Short-Circuit Current Rating (SCCR): | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA |
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Ampere Rating UL/CSA: | 10 A |
Horsepower Rating UL/CSA: | (120 V AC) Single Phase 0.5 Hp |
(220 ... 240 V AC) Single Phase 1.5 Hp | |
Full Load Amps Motor Use: | (120 V AC) Single Phase 9.8 A |
(220 ... 240 V AC) Single Phase 10 A | |
Locked Rotor Amps: | (120 V AC) Single Phase 58.8 A |
(220 ... 240 V AC) Single Phase 58.8 A | |
Connecting Capacity Main Circuit UL/CSA: | Stranded 1/2x 18-10 AWG |
Stranded 1x 8 AWG | |
| |
Ambient Air Temperature: | Around the Enclosure 0 ... +40 °C |
Operation -25 ... +70 °C | |
Operation Compensated -25 ... +60 °C | |
Storage -50 ... +80 °C | |
Ambient Air Temperature Compensation: | Yes |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 25g |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5g / 3 ... 150 Hz |
RoHS Status: | Following EU Directive 2011/65/EU |
| |
CQC Certificate: | CQC2017010307034621 |
cUL Certificate: | cUL_E137861 |
cULus Certificate: | cUL_E137861 |
cUR Certificate: | cUL_E137861 |
Declaration of Conformity - CCC: | 2020980307004600 |
Declaration of Conformity - CE: | 1SAD938508-0188 |
Environmental Information: | 1SAC200049H0009 |
I²t Characteristic: | 1SAM300517F0001 |
Instructions and Manuals: | 2CDC131158M6801 |
Instructions and Manuals (Part 2): | 2CDC131060M0202 |
KC Certificate: | 1SAA963002-1502 |
RMRS Certificate: | 1SAA918000-0704 |
RoHS Information: | 1SAD938508-0188 |
Time-Current Characteristic Curve: | 1SAM300535F0010 |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 50 mm |
Package Level 1 Depth / Length: | 117 mm |
Package Level 1 Height: | 82 mm |
Package Level 1 Gross Weight: | 0.322 kg |
Package Level 1 EAN: | 4013614535208 |
Package Level 2 Units: | 28 piece |
Package Level 2 Width: | 280 mm |
Package Level 2 Depth / Length: | 395 mm |
Package Level 2 Height: | 210 mm |
Package Level 2 Gross Weight: | 13.386 kg |
Package Level 2 EAN: | 4013614535529 |
| |
Object Classification Code: | F |
ETIM 5: | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 6: | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 7: | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
eClass: | V11.0 : 27370409 |
UNSPSC: | 39121601 |
IDEA Granular Category Code (IGCC): | 4813 >> Circuit breakers |
E-Number (Finland): | 3709087 |
Accessories |