Article: MS496-50

We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | MS496-50 |
Product ID: | 1SAM570000R1006 |
EAN: | 4013614265525 |
Catalog Description: | MS496-50 Manual Motor Starter |
Long Description: | The MS496-50 manual motor starter is a 70 mm width devices with a rated operational current of Ie = 50.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and the trip class 20. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases and shunt trips are available as accessory. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362010 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100173C0201 |
Data Sheet, Technical Information (Part 3): | 9AKK105713A1103 |
Instructions and Manuals: | 1SAM507001R1001 |
Time-Current Characteristic Curve: | 1SAM500502F0006 |
| |
Product Net Width: | 70 mm |
Product Net Height: | 165 mm |
Product Net Depth / Length: | 174 mm |
Product Net Weight: | 2.265 kg |
| |
Rated Service Short-Circuit Breaking Capacity (Ics): | (230 V AC) 100 kA |
(400 V AC) 50 kA | |
(440 V AC) 50 kA | |
(500 V AC) 7.5 kA | |
(690 V AC) 5 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (230 V AC) 100 kA |
(400 V AC) 100 kA | |
(440 V AC) 100 kA | |
(500 V AC) 15 kA | |
(690 V AC) 10 kA | |
Rated Instantaneous Short-Circuit Current Setting (Ii): | 650 A |
Setting Range: | 36 ... 50 A |
Rated Operational Power AC-3 (Pe): | (400 V) Three Phase 22 kW |
Rated Operational Voltage: | Main Circuit 690 V AC |
Main Circuit 450 V DC | |
Rated Operational Current (Ie): | 50 A |
Rated Operational Current AC-3 (Ie): | 50 A |
Rated Frequency (f): | Main Circuit 50 Hz |
Main Circuit 60 Hz | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 6 kV |
Rated Insulation Voltage (Ui): | 690 V |
Power Loss: | at Rated Operating Conditions per Pole 3.3 W |
Number of Poles: | 3 |
Conventional Free-air Thermal Current (Ith): | Main Circuit 50 A |
Degree of Protection: | Housing IP20 |
Main Circuit Terminals IP00 | |
Pollution Degree: | 3 |
Electrical Durability: | 25000 cycle |
Mechanical Durability: | 50000 cycle |
Terminal Type: | Screw Terminals |
Connecting Capacity Main Circuit: | Flexible with Ferrule 1x 2.5 ... 50 mm² |
Flexible with Ferrule 2x 2.5 ... 35 mm² | |
Solid 1/2x 2.5 ... 16 mm² | |
Stranded 1x 10 ... 70 mm² | |
Stranded 2x 10 ... 50 mm² | |
Tightening Torque: | Main Circuit 4 ... 6 N·m |
Wire Stripping Length: | Main Circuit 17 mm |
Recommended Screw Driver: | Hexagon 4 |
Mounting Position: | Position 1 to 6 |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
Actuator Type: | Rotary Handle |
Contact Position Indication: | ON / OFF / TRIP |
Standards: | CSA 22.2 No. 14 |
IEC/EN 60947-1 | |
IEC/EN 60947-2 | |
IEC/EN 60947-4-1 | |
UL 508 | |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V AC |
Ampere Rating UL/CSA: | 50 A |
Horsepower Rating UL/CSA: | (200 V AC) Three Phase 15 Hp |
(208 V AC) Three Phase 15 Hp | |
(220 ... 240 V AC) Three Phase 20 Hp | |
(440 ... 480 V AC) Three Phase 40 Hp | |
(550 ... 600 V AC) Three Phase 50 Hp | |
General Use Rating UL/CSA: | (600 V AC) 50 A |
Connecting Capacity Main Circuit UL/CSA: | Flexible 1x 10-2/0 AWG |
Flexible 1/2x 10-1/0 AWG | |
Stranded 1x 10-2/0 AWG | |
Stranded 1/2x 10-1/0 AWG | |
Tightening Torque UL/CSA: | Main Circuit 35 ... 53 in·lb |
| |
Ambient Air Temperature: | Operation -20 ... +70 °C |
Operation Compensated -20 ... +60 °C | |
Storage -50 ... +80 °C | |
Ambient Air Temperature Compensation: | Yes |
Maximum Operating Altitude Permissible: | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 25g |
RoHS Status: | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| |
BV Certificate: | 1SAA937000-0201 |
CQC Certificate: | CQC2013010307604042 |
cUL Certificate: | cUL_E195536 |
Declaration of Conformity - CCC: | 2020980307003525 |
Declaration of Conformity - CE: | 1SAD938502-0050 |
Declaration of Conformity - UKCA: | 1SAD938500-1051 |
DNV Certificate: | 1SAA937000-0302 |
EAC Certificate: | 1SAA937001-2703 |
GL Certificate: | 1SAA937000-0403 |
GOST Certificate: | 1SAA963001-2702 |
Instructions and Manuals: | 1SAM507001R1001 |
LR Certificate: | 1SAA937000-0504 |
RMRS Certificate: | 1SAA918000-0704 |
RoHS Information: | 1SAA918002-4401 |
Time-Current Characteristic Curve: | 1SAM500502F0006 |
UL Certificate: | UL_E167205 |
UL_E195536 | |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 76.5 mm |
Package Level 1 Depth / Length: | 190 mm |
Package Level 1 Height: | 171 mm |
Package Level 1 Gross Weight: | 2.3 kg |
Package Level 1 EAN: | 4013614265525 |
| |
Object Classification Code: | F |
ETIM 4: | EC000074 - Motor protective circuit-breaker |
ETIM 5: | EC000074 - Motor protective circuit-breaker |
ETIM 6: | EC000074 - Motor protection circuit-breaker |
ETIM 7: | EC000074 - Motor protection circuit-breaker |
eClass: | V11.0 : 27370401 |
UNSPSC: | 39121521 |
IDEA Granular Category Code (IGCC): | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |