General Information | |
Extended Product Type: | NFC53E-81 |
Product ID: | 1SBH131001R8153 |
EAN: | 3471523015449 |
Catalog Description: | NFC53E-81 24V 50/60Hz Contactor Relay |
Long Description: | The NFC53E-81 is a contactor relay with 8 auxiliary contacts (5 N.O + 3 N.C) and screw terminals, used to switch auxiliary and control circuits. Within the AF platform, NFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 24 V AC 50/60 Hz). NFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Instructions and Manuals: | 1SBC101059M6801 |
| |
Product Net Width: | 45 mm |
Product Net Depth / Length: | 110.5 mm |
Product Net Height: | 86 mm |
Product Net Weight: | 0.36 kg |
| |
Number of Auxiliary Contacts NO: | 5 |
Number of Auxiliary Contacts NC: | 3 |
Standards: | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
Rated Operational Voltage: | Auxiliary Circuit 690 V |
Main Circuit 690 V | |
Rated Frequency (f): | Auxiliary Circuit 50 / 60 Hz |
Main Circuit 50 / 60 Hz | |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-5-1, q = 40 °C 16 A |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(400 / 440 V) 3 A | |
Rated Short-time Withstand Current (Icw): | for 0.1 s 140 A |
for 1 s 100 A | |
Maximum Electrical Switching Frequency: | (AC-1) 0 cycles per hour |
(AC-15) 1200 cycles per hour | |
(AC-2 / AC-4) 0 cycles per hour | |
(AC-3) 0 cycles per hour | |
(DC-13) 900 cycles per hour | |
Rated Operational Current DC-13 (Ie): | (24 V) 6 A / 144 W |
(48 V) 2.8 A / 134 W | |
(72 V) 1 A / 72 W | |
(110 V) 0.55 A / 60 W | |
(125 V) 0.55 A / 69 W | |
(220 V) 0.27 A / 60 W | |
(250 V) 0.27 A / 68 W | |
(400 V) 0.15 A / 60 W | |
(500 V) 0.13 A / 65 W | |
(600 V) 0.1 A / 60 W | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V | |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Maximum Mechanical Switching Frequency: | 6000 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 24 V |
60 Hz 24 V | |
Operate Time: | Between Coil De-energization and NC Contact Closing 9 ... 20 ms |
Between Coil De-energization and NO Contact Opening 4 ... 18 ms | |
Between Coil Energization and NC Contact Opening 7 ... 21 ms | |
Between Coil Energization and NO Contact Closing 10 ... 26 ms | |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
Rigid 1/2x 1 ... 2.5 mm² | |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Rigid 1/2x 1 ... 2.5 mm² | |
Wire Stripping Length: | Auxiliary Circuit 10 mm |
Control Circuit 10 mm | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
Terminal Type: | Screw Terminals |
Technical UL/CSA | |
Tightening Torque UL/CSA: | Auxiliary Circuit 11 IA |
Control Circuit 11 IA | |
| |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C |
Close to Contactor without Thermal O/L Relay -40 ... +70 °C | |
Close to Contactor for Storage -60 ... +80 °C | |
Near Contactor for Operation in Free Air -40 ... +70 °C | |
Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5 ... 300 Hz 4 g closed position / 2 g open position |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: B1 25 K40 |
Open, Shock Direction: B1 5 K40 | |
Shock Direction: A 30 K40 | |
Shock Direction: B2 15 K40 | |
Shock Direction: C1 25 K40 | |
Shock Direction: C2 25 K40 | |
| |
CB Certificate: | CB_SE-93051M2 |
CQC Certificate: | CQC2019010303267993 |
Declaration of Conformity - CCC: | 2020980303000175 |
Declaration of Conformity - CE: | 1SBD250026U1000 |
Instructions and Manuals: | 1SBC101059M6801 |
RoHS Information: | 1SBD251089E1000 |
UL Certificate: | UL_20191021-E312527_7_1 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 87 mm |
Package Level 1 Depth / Length: | 113 mm |
Package Level 1 Height: | 47 mm |
Package Level 1 Gross Weight: | 0.36 kg |
Package Level 1 EAN: | 3471523015449 |
Package Level 3 Units: | 864 piece |
| |
Object Classification Code: | K |
ETIM 6: | EC000196 - Contactor relay |
ETIM 7: | EC000196 - Contactor relay |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121500 |