Article: NFC51/11-84

Article: NFC51/11-84
NFC51/11-84 110V50Hz 110-120V60Hz Contactor Relay
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | NFC51/11-84 |
Product ID: | 1SBH131001R8459 |
EAN: | 3471523015555 |
Catalog Description: | NFC51/11-84 110V50Hz 110-120V60Hz Contactor Relay |
Long Description: | The NFC51/11-84 is a contactor relay with 8 auxiliary contacts (6 N.O including 1 leading contact + 2 N.C including 1 lagging contact) and screw terminals, used to switch auxiliary and control circuits. Within the AF platform, NFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 110 V AC 50 Hz / 110 … 120 V AC 60 Hz). NFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Instructions and Manuals: | 1SBC101059M6801 |
| |
Product Net Width: | 45 mm |
Product Net Depth / Length: | 110.5 mm |
Product Net Height: | 86 mm |
Product Net Weight: | 0.362 kg |
| |
Number of Auxiliary Contacts NO: | 1 |
Number of Auxiliary Contacts NC: | 5 |
Standards: | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
Rated Operational Voltage: | Auxiliary Circuit 690 V |
Main Circuit 690 V | |
Rated Frequency (f): | Auxiliary Circuit 50 / 60 Hz |
Main Circuit 50 / 60 Hz | |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-5-1, q = 40 °C 16 A |
Rated Operational Current AC-15 (Ie): | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(400 / 440 V) 3 A | |
Rated Short-time Withstand Current (Icw): | for 0.1 s 140 A |
for 1 s 100 A | |
Maximum Electrical Switching Frequency: | (AC-1) 0 cycles per hour |
(AC-15) 1200 cycles per hour | |
(AC-2 / AC-4) 0 cycles per hour | |
(AC-3) 0 cycles per hour | |
(DC-13) 900 cycles per hour | |
Rated Operational Current DC-13 (Ie): | (24 V) 6 A / 144 W |
(48 V) 2.8 A / 134 W | |
(72 V) 1 A / 72 W | |
(110 V) 0.55 A / 60 W | |
(125 V) 0.55 A / 69 W | |
(220 V) 0.27 A / 60 W | |
(250 V) 0.27 A / 68 W | |
(400 V) 0.15 A / 60 W | |
(500 V) 0.13 A / 65 W | |
(600 V) 0.1 A / 60 W | |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V | |
acc. to UL/CSA 600 V | |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Maximum Mechanical Switching Frequency: | 6000 cycles per hour |
Rated Control Circuit Voltage (Uc): | 50 Hz 110 V |
60 Hz 110 ... 120 V | |
Operate Time: | Between Coil De-energization and NC Contact Closing 9 ... 20 ms |
Between Coil De-energization and NO Contact Opening 4 ... 18 ms | |
Between Coil Energization and NC Contact Opening 7 ... 21 ms | |
Between Coil Energization and NO Contact Closing 10 ... 26 ms | |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Rigid 1/2x 1 ... 2.5 mm² | |
Connecting Capacity Control Circuit: | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
Rigid 1/2x 1 ... 2.5 mm² | |
Wire Stripping Length: | Auxiliary Circuit 10 mm |
Control Circuit 10 mm | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
Terminal Type: | Screw Terminals |
Technical UL/CSA | |
Tightening Torque UL/CSA: | Auxiliary Circuit 11 IA |
Control Circuit 11 IA | |
| |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C |
Close to Contactor without Thermal O/L Relay -40 ... +70 °C | |
Close to Contactor for Storage -60 ... +80 °C | |
Near Contactor for Operation in Free Air -40 ... +70 °C | |
Climatic Withstand: | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6: | 5 ... 300 Hz 4 g closed position / 2 g open position |
Resistance to Shock acc. to IEC 60068-2-27: | Closed, Shock Direction: B1 25 K40 |
Open, Shock Direction: B1 5 K40 | |
Shock Direction: A 30 K40 | |
Shock Direction: B2 15 K40 | |
Shock Direction: C1 25 K40 | |
| |
CB Certificate: | CB_SE-93051M2 |
CQC Certificate: | CQC2019010303267993 |
Declaration of Conformity - CCC: | 2020980303000175 |
Declaration of Conformity - CE: | 1SBD250026U1000 |
Instructions and Manuals: | 1SBC101059M6801 |
RoHS Information: | 1SBD251089E1000 |
UL Certificate: | UL_20191021-E312527_7_1 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 87 mm |
Package Level 1 Depth / Length: | 113 mm |
Package Level 1 Height: | 47 mm |
Package Level 1 Gross Weight: | 0.362 kg |
Package Level 1 EAN: | 3471523015555 |
Package Level 3 Units: | 864 piece |
| |
Object Classification Code: | K |
ETIM 6: | EC000196 - Contactor relay |
ETIM 7: | EC000196 - Contactor relay |
eClass: | V11.0 : 27371003 |
UNSPSC: | 39121500 |