Article: NL22ERT 24V DC

Article: NL22ERT 24V DC

NL22ERT 24V DC Contactor Relay
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration



























General Information
Extended Product Type: NL22ERT 24V DC
Product ID: 1SBH143010R8122
EAN: 3471522361813
Catalog Description: NL22ERT 24V DC Contactor Relay
Long Description: NL... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 4-pole contactor relays (mechanically linked contact elements available) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Data Sheet, Technical Information: 1SBC101032D0201
Instructions and Manuals: 1SBC101006M5501
Dimension Diagram: FPTE307902

Dimensions
Product Net Width: 44 mm
Product Net Depth / Length: 97 mm
Product Net Height: 78 mm
Product Net Weight: 0.52 kg

Technical
Number of Main Contacts NO: 0
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 2
Number of Auxiliary Contacts NC: 2
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f): Supply Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-15 (Ie): (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A
Maximum Electrical Switching Frequency: 1200 cycles per hour
Rated Operational Current DC-13 (Ie): (24 V) 6 / 144 A
(48 V) 2.8 / 134 A
(72 V) 1 / 72 A
(125 V) 0.55 / 69 A
(250 V) 0.3 / 75 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Mechanical Durability: > 20 million
Maximum Mechanical Switching Frequency: 6000 cycles per hour
Rated Control Circuit Voltage (Uc): DC Operation 24 V
Coil Consumption: Average Holding Value, from Warm State 3 W
Average Pull-in Value, from Cold State 3 W
Operate Time: Between Coil De-energization and NC Contact Closing 16 ... 27 ms
Between Coil De-energization and NO Contact Opening 10 ... 17 ms
Between Coil Energization and NC Contact Opening 20 ... 70 ms
Between Coil Energization and NO Contact Closing 50 ... 100 ms
Connecting Capacity Auxiliary Circuit: Rigid or Flexible with Cable Lug 0.75 ... 2.5 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP10
Terminal Type: Ring-Tongue Terminals

Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Near Contactor for Operation in Free Air (Uc) +55 ... +70 °C
Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible: 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 10 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B2 10 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 14 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 10 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 8 m/s²
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 8 m/s²
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
CB Certificate: CB_SE_66833A1
CCC Certificate: CCC_2012010304558126
CCC_2006010304174454
CQC Certificate: CQC2012010304558126
CSA Certificate: CSA_1041746
cUR Certificate: UL_20140915-E252354_4_2
Declaration of Conformity - CCC: 2020980303000256
Declaration of Conformity - CE: 1SBD250808U1000
Environmental Information: 1SBD250127E1002
GOST Certificate: GOST_POCCFRME77B07174
Instructions and Manuals: 1SBC101006M5501
RoHS Information: 1SBD250808U1000
UL Certificate: UL_20140915-E252354_4_2
UL Listing Card: E252354

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 86 mm
Package Level 1 Depth / Length: 141 mm
Package Level 1 Height: 51 mm
Package Level 1 Gross Weight: 0.52 kg
Package Level 1 EAN: 3471522361813
Package Level 2 Units: box 28 piece
Package Level 2 Gross Weight: 14.56 kg

Classifications
Object Classification Code: K
ETIM 4: EC000196 - Contactor relay
ETIM 5: EC000196 - Contactor relay
ETIM 6: EC000196 - Contactor relay
ETIM 7: EC000196 - Contactor relay
eClass: V11.0 : 27371018
UNSPSC: 39121500