Article: GF1325-20-22-53

We find the right product
for you
Official reseller
Expert engineering support
Configuration
e):
General Information | |
Extended Product Type: | GF1325-20-22-53 |
Product ID: | 1SFL647731R5322 |
EAN: | 7320500541135 |
Catalog Description: | GF1325-20-22-53 Contactor |
Long Description: | A 2-phase Contactor suitable for PV solar power applications up to max 1500V DC. Operated with wide voltage range 100-250V AC 50/60Hz and DC |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 8536490099 |
Popular Downloads | |
Data Sheet, Technical Information: | 1SBC100218B0201 |
Instructions and Manuals: | 1SFC100003M0001 |
| |
Product Net Width: | 253 mm |
Product Net Depth / Length: | 300 mm |
Product Net Height: | 355 mm |
Product Net Weight: | 14.3 kg |
| |
Number of Main Contacts NO: | 2 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 2 |
Number of Auxiliary Contacts NC: | 2 |
Rated Operational Voltage: | Main Circuit 1500 V |
Rated Frequency (f): | Control Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1375 A |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7920 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1740 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4750 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 9500 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 6340 A | |
Maximum Electrical Switching Frequency: | 15 cycles per hour |
Rated Operational Current DC-1 (Ie): | (1500 V DC) 2-Pole, 40 °C 101 A |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1500 V |
acc. to UL/CSA 1500 V | |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 8 kV |
Mechanical Durability: | 50000 cycle |
Maximum Mechanical Switching Frequency: | 60 cycles per hour |
Coil Operating Limits: | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
Rated Control Circuit Voltage (Uc): | 50 Hz 100...250 V |
60 Hz 100...250 V | |
DC Operation 100...250 V | |
Operate Time: | Between Coil De-energization and NO Contact Opening 33...70 ms |
Between Coil Energization and NO Contact Closing 50...120 ms | |
Connecting Capacity Main Circuit: | Solid 600 mm² |
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
Flexible 2x0.75 ... 2.5 mm² | |
Solid 2x1 ... 4 mm² | |
Stranded 2x1 ... 4 mm² | |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
Terminal Type: | Main Circuit: Bars |
Rated Operational Current DC-PV3 ( | |
I | (1500 V DC) 2-Pole, 60 °C 1325 A |
(1500 V DC) 2-Pole, 70 °C 1050 A | |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Main Circuit 1500 V |
| |
Ambient Air Temperature: | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C |
Close to Contactor for Storage -40 ... +70 °C | |
Maximum Operating Altitude Permissible: | 2000 m |
RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| |
CB Certificate: | 1SFC100042D0101 |
CQC Certificate: | CQC20012271919 |
cUL Certificate: | 1SFC100021D0101 |
Declaration of Conformity - CCC: | 2020980304002803 |
Declaration of Conformity - CE: | 1SFC100019D2701 |
Instructions and Manuals: | 1SFC100003M0001 |
RoHS Information: | 1SFC100019D2701 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 402 mm |
Package Level 1 Depth / Length: | 305 mm |
Package Level 1 Height: | 415 mm |
Package Level 1 Gross Weight: | 16.45 kg |
| |
ETIM 6: | EC002552 - Power contactor, DC switching |
ETIM 7: | EC002552 - Power contactor, DC switching |
eClass: | V11.0 : 27371018 |
UNSPSC: | 39121529 |
IDEA Granular Category Code (IGCC): | 4763 >> Power contactor, DC switching |