Article: GF1325-20-22-53

Article: GF1325-20-22-53

GF1325-20-22-53 Contactor
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration














e):

General Information
Extended Product Type: GF1325-20-22-53
Product ID: 1SFL647731R5322
EAN: 7320500541135
Catalog Description: GF1325-20-22-53 Contactor
Long Description: A 2-phase Contactor suitable for PV solar power applications up to max 1500V DC. Operated with wide voltage range 100-250V AC 50/60Hz and DC

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 8536490099
Popular Downloads
Data Sheet, Technical Information: 1SBC100218B0201
Instructions and Manuals: 1SFC100003M0001

Dimensions
Product Net Width: 253 mm
Product Net Depth / Length: 300 mm
Product Net Height: 355 mm
Product Net Weight: 14.3 kg

Technical
Number of Main Contacts NO: 2
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 2
Number of Auxiliary Contacts NC: 2
Rated Operational Voltage: Main Circuit 1500 V
Rated Frequency (f): Control Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1375 A
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7920 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1740 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4750 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 9500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 6340 A
Maximum Electrical Switching Frequency: 15 cycles per hour
Rated Operational Current DC-1 (Ie): (1500 V DC) 2-Pole, 40 °C 101 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1500 V
acc. to UL/CSA 1500 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 50000 cycle
Maximum Mechanical Switching Frequency: 60 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc): 50 Hz 100...250 V
60 Hz 100...250 V
DC Operation 100...250 V
Operate Time: Between Coil De-energization and NO Contact Opening 33...70 ms
Between Coil Energization and NO Contact Closing 50...120 ms
Connecting Capacity Main Circuit: Solid 600 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2x1 ... 4 mm²
Stranded 2x1 ... 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type: Main Circuit: Bars
Rated Operational Current DC-PV3 (
I (1500 V DC) 2-Pole, 60 °C 1325 A
(1500 V DC) 2-Pole, 70 °C 1050 A
Technical UL/CSA
Maximum Operating Voltage UL/CSA: Main Circuit 1500 V

Environmental
Ambient Air Temperature: Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Close to Contactor for Storage -40 ... +70 °C
Maximum Operating Altitude Permissible: 2000 m
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Certificates and Declarations (Document Number)
CB Certificate: 1SFC100042D0101
CQC Certificate: CQC20012271919
cUL Certificate: 1SFC100021D0101
Declaration of Conformity - CCC: 2020980304002803
Declaration of Conformity - CE: 1SFC100019D2701
Instructions and Manuals: 1SFC100003M0001
RoHS Information: 1SFC100019D2701

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 402 mm
Package Level 1 Depth / Length: 305 mm
Package Level 1 Height: 415 mm
Package Level 1 Gross Weight: 16.45 kg

Classifications
ETIM 6: EC002552 - Power contactor, DC switching
ETIM 7: EC002552 - Power contactor, DC switching
eClass: V11.0 : 27371018
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4763 >> Power contactor, DC switching