Article: EN40-31N-06

We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
| Extended Product Type: | EN40-31N-06 |
| Product ID: | 1SAE342111M0631 |
| Catalog Description: | EN40-31N-06 Installation Contactors |
| Long Description: | The EN40..N installation contactors are used to control single and three-phase loads up to 40 A and can be operated by AC or DC and/or manually.These contactors are made for use in household applications as well as in industrial environments.The following benefits are provided:Hum-free operation, low power consumption, integrated overvoltage protection and manual override.Various contact combinations and accessories are available.Manual operation is available in 3 states: "On", "Off", "Auto" |
| |
| Package Level 1 EAN: | 4013614520570 |
| Minimum Order Quantity: | 4 piece |
| Customs Tariff Number: | 85365080 |
| Popular Downloads | |
| Instructions and Manuals: | 2CDC103043M6801 |
| |
| Product Net Width: | 54 mm |
| Product Net Height: | 85 mm |
| Product Net Depth / Length: | 65 mm |
| Product Net Weight: | 0.41 kg |
| |
| Rated Operational Voltage: | Main Circuit 220 V DC |
| Main Circuit 400 V AC | |
| Rated Control Circuit Voltage (Uc): | 230 V |
| Rated Frequency (f): | Control Circuit 400 Hz |
| Control Circuit 50 Hz | |
| Control Circuit 60 Hz | |
| Control Circuit DC | |
| Main Circuit 50 Hz | |
| Main Circuit 60 Hz | |
| Main Circuit DC | |
| Rated Operational Current AC-1 (Ie): | (NC) 30 A |
| (NO) 40 A | |
| Rated Operational Current AC-3 (Ie): | (230 V) Single Phase, NO 22 A |
| (400 V) Three Phase, NO 22 A | |
| Rated Operational Power AC-1 (Pe): | (230 V) Single Phase, NC 6.9 kW |
| (230 V) Single Phase, NO 9.2 kW | |
| (400 V) Three Phase, NO 27.7 kW | |
| Rated Operational Power AC-3 (Pe): | (230 V) Single Phase, NO 3.7 kW |
| (400 V) Three Phase, NO 11 kW | |
| Rated Operational Current AC-7a (Ie): | (NO) 40 A |
| Rated Operational Power AC-7a (Pe): | (230 V) Single Phase, NC 6.9 kW |
| (230 V) Single Phase, NO 9.2 kW | |
| (400 V) Three Phase, NO 27.7 kW | |
| Rated Operational Current AC-7b (Ie): | (230 V) Single Phase, NO 22 A |
| (400 V) Three Phase, NO 22 A | |
| Rated Operational Power AC-7b (Pe): | (230 V) Single Phase, NO 3.7 kW |
| (400 V) Three Phase, NO 11 kW | |
| Recommended Screw Driver: | Control Circuit Pozidriv 1 |
| Main Circuit Pozidriv 2 | |
| Rated Impulse Withstand Voltage (Uimp): | 4 kV |
| Rated Insulation Voltage (Ui): | 500 V |
| Connecting Capacity Main Circuit: | Flexible with Ferrule 1x 1.5 ... 16 mm² |
| Flexible with Ferrule 2x 1.5 ... 10 mm² | |
| Flexible with Insulated Ferrule 1x 1.5 ... 16 mm² | |
| Flexible with Insulated Ferrule 2x 1.5 ... 10 mm² | |
| Flexible 1x 1.5 ... 16 mm² | |
| Flexible 2x 1.5 ... 10 mm² | |
| Rigid 1x 1.5 ... 25 mm² | |
| Rigid 2x 1.5 ... 10 mm² | |
| Connecting Capacity Control Circuit: | Flexible with Ferrule 1x 1 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.75 ... 1.5 mm² | |
| Flexible with Insulated Ferrule 1x 1 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1 mm² | |
| Flexible 1x 1 ... 2.5 mm² | |
| Flexible 2x 1 ... 1.5 mm² | |
| Rigid 1x 1 ... 4 mm² | |
| Rigid 2x 1 ... 2.5 mm² | |
| Tightening Torque: | Control Circuit 0.9 N·m |
| Main Circuit 2.5 N·m | |
| Wire Stripping Length: | Control Circuit 7 mm |
| Main Circuit 13 mm | |
| Degree of Protection: | IP20 |
| Electrical Durability: | AC-1 (NO) 150000 cycle |
| AC-3 (NO) 150000 cycle | |
| AC-7a (NO) 150000 cycle | |
| AC-7b (NO) 150000 cycle | |
| Mechanical Durability: | 1000000 cycle |
| Number of Poles: | 4 |
| Number of Main Contacts NC: | 1 |
| Number of Main Contacts NO: | 3 |
| Width in Number of Modular Spacings: | 3 |
| Pollution Degree: | 3 |
| |
| Ambient Air Temperature: | Operation -25 ... +55 °C |
| Storage -40 ... +80 °C | |
| Maximum Operating Altitude Permissible: | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27: | 11 ms Pulse 15g |
| RoHS Status: | Following EU Directive 2011/65/EU |
| |
| CB Certificate: | 1SAA920005-2001 |
| CQC Certificate: | CQC2017010304993562 |
| Declaration of Conformity - CCC: | 2020980304001310 |
| Declaration of Conformity - CE: | 1SAD938506-0302 |
| Declaration of Conformity - UKCA: | 1SAD938500-1302 |
| EAC Certificate: | 1SAA920001-2702 |
| Environmental Information: | 1SAC200064H0009 |
| Instructions and Manuals: | 2CDC103043M6801 |
| RMRS Certificate: | 1SAA920000-0705 |
| RoHS Information: | 1SAD938506-0302 |
| |
| Package Level 1 Units: | 4 piece |
| Package Level 1 Width: | 88 mm |
| Package Level 1 Height: | 69.5 mm |
| Package Level 1 Depth / Length: | 222 mm |
| Package Level 1 Gross Weight: | 1.64 kg |
| Package Level 1 EAN: | 4013614520570 |
| |
| Object Classification Code: | Q |
| ETIM 5: | EC001653 - Installation contactor for distribution board |
| ETIM 6: | EC001653 - Installation contactor for distribution board |
| ETIM 7: | EC001653 - Installation contactor for distribution board |
| eClass: | V11.0 : 27142308 |
| UNSPSC: | 39121529 |
| IDEA Granular Category Code (IGCC): | 4759 >> Installation contactor for distribution board |