Article: CM-MPS.23S

Article: CM-MPS.23S
CM-MPS.23S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3-N=3x180-280VAC
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | CM-MPS.23S |
Product ID: | 1SVR730885R4300 |
EAN: | 4016779851909 |
Catalog Description: | CM-MPS.23S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3-N=3x180-280VAC |
Long Description: | The CM-MPN.23S is a multifunctional relay from the CM three-phase monitors range. It operates with a rated control supply voltage / three-phase measuring voltage of 180-280 V AC 50/60/400 Hz and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. This relay is also suitable to monitor single-phase mains. It monitors all phase parameters such as over/undervoltage, phase unbalance, phase failure as well as an interrupted neutral. The corresponding threshold values are adjustable. The CM-MPN.23S also offers selection of phase sequence monitoring, automatic phase sequence correction as well as an ON or OFF tripping delay. The output contacts can be configured as 1x2 c/o (SPDT) contacts (common signal) or 2x1 c/o (SPDT) contact (separate signal for over- and undervoltage thresholds) operation. The tripping delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers screw connection technology with double-chamber cage connection terminals. |
| |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Popular Downloads | |
Data Sheet, Technical Information: | 2CDC112203D0201 |
Instructions and Manuals: | 1SVC730510M1001 |
| |
Product Net Width: | 22.5 mm |
Product Net Depth / Length: | 103.7 mm |
Product Net Height: | 85.6 mm |
Product Net Weight: | 0.149 kg |
| |
Function: | Phase failure detection |
Phase sequence monitoring | |
Automatic phase sequence correction | |
Over- and undervoltage monitoring | |
Phase unbalance detection | |
Interrupted neutral monitoring | |
Standards: | CAN/CSA C22.2 No.14 |
IEC/EN 63000 | |
IEC/EN 60255-27 | |
IEC/EN 61000-6-2 | |
IEC/EN 61000-6-3 | |
UL 508 | |
Measuring Range: | (L-N) 180 ... 280 V AC |
Rated Control Supply Voltage (Us): | (L-N) 180 ... 280 V AC |
Rated Frequency (f): | Supply Circuit 50/60/400 Hz |
Output: | 2 x 1 c/o or 1 x 2 c/o contacts, configurable |
Time Range: | 200 ms start-up delay |
0 s or 0.1 ... 30 s tripping delay (ON or OFF) | |
Terminal Type: | Screw Terminals |
Rated Operational Current AC-12 (Ie): | (230 V) 4 A |
Rated Operational Current AC-15 (Ie): | (230 V) 3 A |
Rated Operational Current DC-12 (Ie): | (24 V) 4 A |
Rated Operational Current DC-13 (Ie): | (24 V) 2 A |
Minimum Switching Capacity: | 24 V |
10 mA | |
Rated Insulation Voltage (Ui): | Input Circuit / Output Circuit 600 V |
Output Circuit 1 / Output Circuit 2 300 V | |
Rated Impulse Withstand Voltage (Uimp): | Input Circuit 6 kV |
Output Circuit 4 kV | |
Degree of Protection: | Housing IP50 |
Terminals IP20 | |
Overvoltage Category: | III |
Pollution Degree: | 3 |
Short-Circuit Protective Devices: | Output Circuit NC - F Type Fuses 6 A |
Output Circuit NO - F Type Fuses 10 A | |
Electrical Durability: | AC-12 100000 cycle |
Mechanical Durability: | 30000000 cycle |
Connecting Capacity: | Flexible with Ferrule 1x 0.5 ... 2.5 mm² |
Flexible with Ferrule 2x 0.5 ... 1.5 mm² | |
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² | |
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
Flexible 1x 0.5 ... 2.5 mm² | |
Flexible 2x 0.5 ... 1.5 mm² | |
Rigid 1x 0.5 ... 4 mm² | |
Rigid 2x 0.5 ... 2.5 mm² | |
Tightening Torque: | 0.6 ... 0.8 N·m |
Wire Stripping Length: | 8 mm |
Recommended Screw Driver: | Pozidriv 1 |
4.5 | |
0.8 x 4 | |
Mounting Position: | Any |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| |
Ambient Air Temperature: | Operation -25 ... +60 °C |
Storage -40 ... +85 °C | |
RoHS Status: | Following EU Directive 2011/65/EU |
Technical UL/CSA | |
Maximum Operating Voltage UL/CSA: | Output Circuit 300 V AC |
Contact Rating UL/CSA: | B300 |
Connecting Capacity UL/CSA: | Flexible 1x 18-14 AWG |
Flexible 2x 18-16 AWG | |
Rigid 1x 20-12 AWG | |
Rigid 2x 20-14 AWG | |
Tightening Torque UL/CSA: | 7.08 in·lb |
| |
CB Certificate: | CB_DK-27947-UL |
CCC Certificate: | CCC_2009010303326655 |
CQC Certificate: | CQC2009010303326655 |
cULus Certificate: | cULus508_20120829-E140448 |
Declaration of Conformity - CCC: | 2020980303000197 |
Declaration of Conformity - CE: | 1SVD981014-00 |
Declaration of Conformity - UKCA: | 1SVD981014-10 |
DNV GL Certificate: | DNV_GL_TAA000017D |
EAC Certificate: | EAC_RU_C-DE.ME77.B.03424 |
Instructions and Manuals: | 1SVC730510M1001 |
RMRS Certificate: | RMRS_1740020250 |
RoHS Information: | 1SVD981014-00 |
| |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 97 mm |
Package Level 1 Height: | 109 mm |
Package Level 1 Depth / Length: | 30 mm |
Package Level 1 Gross Weight: | 0.174 kg |
Package Level 1 EAN: | 4016779851909 |
| |
Object Classification Code: | B |
ETIM 4: | EC001441 - Phase monitoring relay |
ETIM 5: | EC001441 - Phase monitoring relay |
ETIM 6: | EC001441 - Phase monitoring relay |
ETIM 7: | EC001441 - Phase monitoring relay |
eClass: | V11.0 : 27371803 |
UNSPSC: | 39121536 |
E-Number (Finland): | 2712274 |
E-Number (Sweden): | 3860591 |