Article: UA30-30-10RA 48V 50Hz / 48V 60Hz

Article: UA30-30-10RA 48V 50Hz / 48V 60Hz

UA30-30-10RA 48V 50Hz / 48V 60Hz Contactor
We find the right product for you
info@quadindustry.com
+49 (2191) 5992017
Official reseller
Expert engineering support

Configuration







































General Information
Extended Product Type: UA30-30-10RA 48V 50Hz / 48V 60Hz
Product ID: 1SBL281024R8310
EAN: 3471522302830
Catalog Description: UA30-30-10RA 48V 50Hz / 48V 60Hz Contactor
Long Description: UA30..RA 3-pole contactors for capacitor switching, can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances (see table below). The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. Their electrical durability is 250 000 operating cycles for Ue < 500 V and 100 000 operating cycles for 500 V ≤ Ue ≤ 690 V. The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank. Their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles. The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level. The UA..RA series 3-pole contactors are of the block type design. - Main poles and auxiliary contacts: 3 main poles, 1 built-in auxiliary contact - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Popular Downloads
Data Sheet, Technical Information: 1SBC101140C0203
Instructions and Manuals: 1SBC101002M5501
Dimension Diagram: FPTE307845

Dimensions
Product Net Width: 54 mm
Product Net Depth / Length: 141 mm
Product Net Height: 130 mm
Product Net Weight: 0.81 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 0
Rated Operational Voltage: Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f): Supply Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Power AC-6b (Pe): (230 / 240 V) 40 °C, 50 / 60 Hz 16 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 16 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 11 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 30 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 19.5 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 27.5 kvar
(440 V) 40 °C, 50 / 60 Hz 32 kvar
(440 V) 55 °C, 50 / 60 Hz 30 kvar
(440 V) 70 °C, 50 / 60 Hz 20.5 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 34 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 34 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 25 kvar
(690 V) 40 °C, 50 / 60 Hz 45 kvar
(690 V) 55 °C, 50 / 60 Hz 45 kvar
(690 V) 70 °C, 50 / 60 Hz 32 kvar
Rated Operational Current AC-15 (Ie): (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 200 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Maximum Electrical Switching Frequency: 240 cycles per hour
Rated Operational Current DC-13 (Ie): (24 V) 6 / 144 A
(48 V) 2.8 / 134 A
(72 V) 2 / 144 A
(125 V) 1.1 / 138 A
(250 V) 0.55 / 138 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 8 kV
Rated Control Circuit Voltage (Uc): 50 Hz 48 V
60 Hz 48 V
Coil Consumption: Average Holding Value 50 / 60 Hz 12 V·A
Average Holding Value 50 Hz 12 V·A
Average Holding Value 60 Hz 12 V·A
Average Pull-in Value 50 Hz 120 V·A
Average Pull-in Value 60 Hz 140 V·A
Operate Time: Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 8 ... 21 ms
Connecting Capacity Main Circuit: Flexible with Cable End 2.5 ... 4 mm²
Rigid Cable 2.5 ... 6 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Connecting Terminals (delivered in open position) Main Poles: M 5 (+,-) pozidriv 2 screws with 2x (5.6x6.5 mm) connector
Terminal Type: Screw Terminals

Environmental
Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... 55 °C
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible: Without Derating 3000 m
RoHS Status: Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)
CB Certificate: CB_FR3448_60016915-509739C
CCC Certificate: CCC_2004010304138316
CQC Certificate: CQC2003010304060095
CQC2007010309256050
CSA Certificate: CSA_1033838_LR056745
Declaration of Conformity - CCC: 2020980304001610
2020980304001216
Declaration of Conformity - CE: 1SBD250805U1000
Environmental Information: 1SBD250123E1000
GOST Certificate: GOST_POCCFRME77B07175
Instructions and Manuals: 1SBC101002M5501
RoHS Information: 1SBD250805U1000

Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 135 mm
Package Level 1 Depth / Length: 155 mm
Package Level 1 Height: 63 mm
Package Level 1 Gross Weight: 0.81 kg
Package Level 1 EAN: 3471522302830
Package Level 2 Units: box 24 piece
Package Level 2 Gross Weight: 19.44 kg

Classifications
Object Classification Code: Q
ETIM 4: EC001079 - Capacitor magnet contactor
ETIM 5: EC001079 - Capacitor magnet contactor
ETIM 6: EC001079 - Capacitor contactor
ETIM 7: EC001079 - Capacitor contactor
eClass: V11.0 : 27371006
UNSPSC: 39121529