Article: T5N 400 MF 400 Im=4000 3p FF xMAC.MAIN.

Article: T5N 400 MF 400 Im=4000 3p FF xMAC.MAIN.
T5N 400 MF 400 Im=4000 3p FF xMAC.MAIN.
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | T5N 400 MF 400 Im=4000 3p FF xMAC.MAIN. |
Product ID: | 1SDA069141R1 |
EAN: | 8015644698423 |
Catalog Description: | T5N 400 MF 400 Im=4000 3p FF xMAC.MAIN. |
Long Description: | C.BREAKER TMAX T5N 400 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE THREE-POLE IN AC-DC MF Iu 400 I3=4000 A WITH: AUE T4-T5 250Vac/dc 2 EARLY CONTACTS RHE T4-T5 F/P STAND. RETURNED |
| |
EAN: | 8015644698423 |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362090 |
| |
Product Net Width: | 140 mm |
Product Net Height: | 205 mm |
Product Net Depth / Length: | 103.5 mm |
Product Net Weight: | 5.6 kg |
| |
Package Level 1 EAN: | 8015644698423 |
| |
RoHS Status: | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| |
Number of Poles: | 3 |
Power Loss: | at Rated Operating Conditions per Pole 19.5 W |
Product Main Type: | SACE Tmax T |
Product Name: | Moulded Case Circuit Breaker |
Product Type: | CB |
Rated Current (In): | Main Circuit 400 A |
Rated Operational Voltage: | 690 V AC |
750 V DC | |
Rated Service Short-Circuit Breaking Capacity (Ics): | (220 V AC) 70 kA |
(230 V AC) 70 kA | |
(380 V AC) 36 kA | |
(400 V AC) 36 kA | |
(415 V AC) 36 kA | |
(440 V AC) 30 kA | |
(500 V AC) 25 kA | |
(690 V) 20 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (220 V AC) 70 kA |
(230 V AC) 70 kA | |
(380 V AC) 36 kA | |
(400 V AC) 36 kA | |
(415 V AC) 36 kA | |
(440 V AC) 30 kA | |
(500 V AC) 25 kA | |
(690 V AC) 20 kA | |
(250 V DC) 2 Poles in Series 36 kA | |
(250 V DC) 3 Poles in Series 25 kA | |
(500 V DC) 3 Poles in Series 16 kA | |
Rated Uninterrupted Current (Iu): | 400 A |
Release: | MF |
Release Type: | M |
Short-Circuit Performance Level: | N |
Standards: | IEC 60947 |
Sub-type: | T5 |
Terminal Connection Type: | Fixed Circuit-Breakers |
Front | |
Version: | F |
| |
Data Sheet, Technical Information: | 1SDC210023D0201 |
Declaration of Conformity - CE: | 1SDL000165R0005 |
Environmental Information: | 9AKK10103A1056 |
Instructions and Manuals: | 1SDC210033D0202 |
REACH Declaration: | 9AKK108466A1425 |
RoHS Information: | 9AKK108466A1424 |
| |
ETIM 4: | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 5: | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 6: | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 7: | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code: | Q |
WEEE Category: | 5. Small Equipment (No External Dimension More Than 50 cm) |